Studies on Ti-Zr-Cr-Mn-Fe-V based alloys for hydrogen compression under mild thermal conditions of water bath

2021 ◽  
pp. 162145
Author(s):  
Ziming Cao ◽  
Panpan Zhou ◽  
Xuezhang Xiao ◽  
Liujun Zhan ◽  
Zhifei Jiang ◽  
...  
TAPPI Journal ◽  
2013 ◽  
Vol 12 (11) ◽  
pp. 21-26 ◽  
Author(s):  
CHAO TIAN ◽  
LINQIANG ZHENG ◽  
QINGXIAN MIAO ◽  
CHRIS NASH ◽  
CHUNYU CAO ◽  
...  

The Fock test is widely used for assessing the reactivity of dissolving pulp. The objective of this study was to modify the method to improve the repeatability of the test. Various parameters that affect the repeatability of the Fock test were investigated. The results showed that Fock reactivity is dependent on testing conditions affecting the xanthation between cellulose and carbon disulfide, such as the moisture content of the pulp sample, sodium hydroxide (NaOH) concentration, xanthation temperature, carbon disulfide dosage, and xanthation time. The repeatability of the test was significantly improved using the following modified testing procedure: air dried sample in the constant temperature/humidity room, xanthation temperature of 66°F (19°C) in a water bath, xanthation time of 3 h, NaOH concentration of 9% (w/w), and 1.3 mL carbon disulfide.


2018 ◽  
pp. 155-162 ◽  
Author(s):  
Sergei S. Kapitonov ◽  
Anastasia V. Kapitonova ◽  
Sergei Yu. Grigorovich ◽  
Sergei A. Medvedev ◽  
Taher Sobhy

In the article, the electrical and thermal processes in the LED lamp with varied parameters are investigated. Voltage and current measurements on all LEDs of the luminaire are carried out in the nominal operating mode. The power allocated to each LED is determined. The calculation of the LED crystal temperature was carried out using the developed thermal LED model based on the results of the measurements and by using “Multisim” program. It has been established that the temperature of the crystals of individual LEDs in the luminaire differ significantly, which leads to unfavourable thermal conditions for them and an increased likelihood of premature failure.


2019 ◽  
Vol 3 (2) ◽  
pp. 35
Author(s):  
Kartini Kartini ◽  
Azminah Azminah

In order to prepare standardized extract, optimization of extraction conditions of grape seed has been done. These conditions are type of menstrum (50, 70 and 96% of ethanolic solution), length of extraction (1, 2 and 4 hours) also method of evaporation (reduced pressure and opened air). Activity on free radical scavenger used as parameters to determine optimum conditions. Based on EC50 (concentration which scavenge 50% amount of free radical) can be concluded that optimum condition for extracting antioxidant active compound from grape seed are 70% ethanolic solution as menstrum, length of extraction 1 hour and evaporation on opened air use water bath.


Author(s):  
M.A. Nisbet ◽  
S. Schmeller

AbstractBoth the vapour and particulate phases of tobacco smoke have been shown to retard benzoyI-peroxide-initiated polymerisation of vinyl acetate by interception of the radicals involved in the polymerisation process. The extent of inhibition of polymerisation by test compounds is estimated by measuring time taken for a mixture of monomer and benzoyl peroxide, immersed in a water-bath at 70°C, to reach a spontaneous boil and comparing it with the time required for a similar mixture with added retarder to reach boiling point. Units are expressed as minutes of inhibition per part per million of inhibitor × 10


2017 ◽  
Vol 191 ◽  
pp. 176-195 ◽  
Author(s):  
Igor D. Rostov ◽  
Elena V. Dmitrieva ◽  
Alexander A. Vorontsov

2020 ◽  
Vol 38 (9A) ◽  
pp. 1257-1275
Author(s):  
Wisam M. Mareed ◽  
Hasanen M. Hussen

 Elevated CO2 rates in a building affect the health of the occupant. This paper deals with an experimental and numerical analysis conducted in a full-scale test room located in the Department of Mechanical Engineering at the University of Technology. The experiments and CFD were conducted for analyzing ventilation performance. It is a study on the effect of the discharge airflow rate of the ceiling type air-conditioner on ventilation performance in the lecture room with the mixing ventilation. Most obtained findings show that database and questionnaires analyzed prefer heights between 0.2 m to 1.2 m in the middle of an occupied zone and breathing zone height of between 0.75 m to 1.8 given in the literature surveyed. It is noticed the mismatch of internal conditions with thermal comfort, and indoor air quality recommended by [ASHRAE Standard 62, ANSI / ASHRAE Standard 55-2010]. CFD simulations have been carried to provide insights on the indoor air quality and comfort conditions throughout the classroom. Particle concentrations, thermal conditions, and modified ventilation system solutions are reported.


Sign in / Sign up

Export Citation Format

Share Document