scholarly journals Load transfer mechanics between trans-tibial prosthetic socket and residual limb—dynamic effects

2004 ◽  
Vol 37 (9) ◽  
pp. 1371-1377 ◽  
Author(s):  
Xiaohong Jia ◽  
Ming Zhang ◽  
Winson C.C Lee
2019 ◽  
Vol 19 (4) ◽  
pp. 1347-1360 ◽  
Author(s):  
J. W. Steer ◽  
P. A. Grudniewski ◽  
M. Browne ◽  
P. R. Worsley ◽  
A. J. Sobey ◽  
...  

AbstractIn post-amputation rehabilitation, a common goal is to return to ambulation using a prosthetic limb, suspended by a customised socket. Prosthetic socket design aims to optimise load transfer between the residual limb and mechanical limb, by customisation to the user. This is a time-consuming process, and with the increase in people requiring these prosthetics, it is vital that these personalised devices can be produced rapidly while maintaining excellent fit, to maximise function and comfort. Prosthetic sockets are designed by capturing the residual limb’s shape and applying a series of geometrical modifications, called rectifications. Expert knowledge is required to achieve a comfortable fit in this iterative process. A variety of rectifications can be made, grouped into established strategies [e.g. in transtibial sockets: patellar tendon bearing (PTB) and total surface bearing (TSB)], creating a complex design space. To date, adoption of advanced engineering solutions to support fitting has been limited. One method is numerical optimisation, which allows the designer a number of likely candidate solutions to start the design process. Numerical optimisation is commonly used in many industries but not prevalent in the design of prosthetic sockets. This paper therefore presents candidate shape optimisation methods which might benefit the prosthetist and the limb user, by blending the state of the art from prosthetic mechanical design, surrogate modelling and evolutionary computation. The result of the analysis is a series of prosthetic socket designs that preferentially load and unload the pressure tolerant and intolerant regions of the residual limb. This spectrum is bounded by the general forms of the PTB and TSB designs, with a series of variations in between that represent a compromise between these accepted approaches. This results in a difference in pressure of up to 31 kPa over the fibula head and 14 kPa over the residuum tip. The presented methods would allow a trained prosthetist to rapidly assess these likely candidates and then to make final detailed modifications and fine-tuning. Importantly, insights gained about the design should be seen as a compliment, not a replacement, for the prosthetist’s skill and experience. We propose instead that this method might reduce the time spent on the early stages of socket design and allow prosthetists to focus on the most skilled and creative tasks of fine-tuning the design, in face-to-face consultation with their client.


Materials ◽  
2020 ◽  
Vol 13 (18) ◽  
pp. 3955
Author(s):  
Kathryn Rankin ◽  
Joshua Steer ◽  
Joshua Paton ◽  
Mark Mavrogordato ◽  
Alexander Marter ◽  
...  

Personalised prosthetic sockets are fabricated by expert clinicians in a skill- and experience-based process, with research providing tools to support evidence-based practice. We propose that digital volume correlation (DVC) may offer a deeper understanding of load transfer from prosthetic sockets into the residual limb, and tissue injury risk. This study’s aim was to develop a transtibial amputated limb analogue for volumetric strain estimation using DVC, evaluating its ability to distinguish between socket designs. A soft tissue analogue material was developed, comprising silicone elastomer and sand particles as fiducial markers for image correlation. The material was cast to form an analogue residual limb informed by an MRI scan of a person with transtibial amputation, for whom two polymer check sockets were produced by an expert prosthetist. The model was micro-CT scanned according to (i) an unloaded noise study protocol and (ii) a case study comparison between the two socket designs, loaded to represent two-legged stance. The scans were reconstructed to give 108 µm voxels. The DVC noise study indicated a 64 vx subvolume and 50% overlap, giving better than 0.32% strain sensitivity, and ~3.5 mm spatial resolution of strain. Strain fields induced by the loaded sockets indicated tensile, compressive and shear strain magnitudes in the order of 10%, with a high signal:noise ratio enabling distinction between the two socket designs. DVC may not be applicable for socket design in the clinical setting, but does offer critical 3D strain information from which existing in vitro and in silico tools can be compared and validated to support the design and manufacture of prosthetic sockets, and enhance the biomechanical understanding of the load transfer between the limb and the prosthesis.


2021 ◽  
Author(s):  
William Anderst ◽  
Goeran Fiedler ◽  
Kentaro Onishi ◽  
Gina McKernan ◽  
Tom Gale ◽  
...  

Abstract • Background: Among the challenges of living with lower limb loss is the increased risk of long-term health problems that can be either attributed directly to the amputation surgery and/or prosthetic rehabilitation or indirectly to a disability-induced sedentary lifestyle. These problems are exacerbated by poorly fit prosthetic sockets. There is a knowledge gap regarding how the socket design affects in-socket mechanics, and how in-socket mechanics affect patient-reported comfort and function. The objectives of this study are: 1) to gain a better understanding of how in-socket mechanics of the residual limb in transfemoral amputees are related to patient-reported comfort and function, 2) to identify clinical tests that can streamline the socket design process, and 3) to evaluate the efficacy and cost of a novel, quantitatively informed socket optimization process.• Methods: Users of transfemoral prostheses will be asked to walk on a treadmill wearing their current socket plus 8 different check sockets with designed changes in different structural measurements that are likely to induce changes in residual limb motion, skin strain, and pressure distribution within the socket. Dynamic biplane radiography and pressure sensors will be used to measure in-socket residual limb mechanics. Patient-reported outcomes will also be collected after wearing each socket. The effects of in-socket mechanics on both physical function and patient-reported outcomes (aim 1) will be assessed using a generalized linear model. Partial correlation analysis will be used to examine the association between research grade measurements and readily available clinical measurements (aim 2). In order to compare the new quantitative design method to the Standard of Care, patient reported outcomes and cost will be compared between the two methods, utilizing the Wilcoxon Mann-Whitney non-parametric test (aim 3).• Discussion: Knowledge on how prosthetic socket modifications affect residual bone and skin biomechanics itself can be applied to devise future socket designs, and the methodology can be used to investigate and improve such designs, past and present. Apart from saving time and costs, this may result in better prosthetic socket fit for a large patient population, thus increasing their mobility, participation, and overall health-related quality of life. • Trial registration: clinicaltrials.gov: NCT05041998


2020 ◽  
Vol 44 (5) ◽  
pp. 355-358 ◽  
Author(s):  
Eric Nickel ◽  
Kyle Barrons ◽  
Barry Hand ◽  
Alana Cataldo ◽  
Andrew Hansen

Background and Aim: During post-amputation recovery or rapid body mass change, residual limb volume can change quickly, requiring frequent adjustments or replacement of the socket to maintain fit. The aim of this pilot test was to evaluate the feasibility of using a three-dimensional-printed insert to extend the service life of a prosthetic socket after substantial residual limb volume loss. Technique: One research subject with a well-fitting transtibial prosthetic socket had an oversized socket fabricated to simulate substantial limb volume loss. The digital shapes of the oversized and well-fitting sockets were used to create a three-dimensional-printed insert to restore fit. Discussion: Two-minute walk test distance decreased when using the oversized socket without the insert, but not when using the socket with the insert. Socket comfort score was 8+ under all conditions. These results suggest that three-dimensional-printed inserts may be an effective method of extending the service life of prosthetic sockets when rapid limb volume loss occurs. Clinical relevance Three-dimensional (3D) printing gives prosthetists a new tool to manage large volume changes without refabricating entire sockets. Sockets can be fabricated in anticipation of volume gain/loss, using replaceable 3D-printed inserts to maintain fit and comfort.


2012 ◽  
Vol 2012 ◽  
pp. 1-10 ◽  
Author(s):  
Mohammad Reza Safari ◽  
Philip Rowe ◽  
Arjan Buis

Lower limb prosthetic socket shape and volume consistency can be quantified using MRI technology. Additionally, MRI images of the residual limb could be used as an input data for CAD-CAM technology and finite element studies. However, the accuracy of MRI when socket casting materials are used has to be defined. A number of six, 46 mm thick, cross-sections of an animal leg were used. Three specimens were wrapped with Plaster of Paris (POP) and the other three with commercially available silicone interface liner. Data was obtained by utilising MRI technology and then the segmented images compared to corresponding calliper measurement, photographic imaging, and water suspension techniques. The MRI measurement results were strongly correlated with actual diameter, surface area, and volume measurements. The results show that the selected scanning parameters and the semiautomatic segmentation method are adequate enough, considering the limit of clinical meaningful shape and volume fluctuation, for residual limb volume and the cross-sectional surface area measurements.


2012 ◽  
Vol 24 (1) ◽  
pp. 19-24 ◽  
Author(s):  
W. Lee Childers ◽  
Karen L. Perell-Gerson ◽  
Robert J. Gregor

2016 ◽  
Vol 41 (5) ◽  
pp. 527-531 ◽  
Author(s):  
Kay Mitton ◽  
Jai Kulkarni ◽  
Kenneth William Dunn ◽  
Anthony Hoang Ung

Background: This novel case report describes the problems of prescribing a prosthetic socket in a left transfemoral amputee secondary to chronic patellofemoral instability compounded by complex regional pain syndrome. Case Description and Methods: Following the amputation, complex regional pain syndrome symptoms recurred in the residual limb, presenting mainly with oedema. Due to extreme daily volume fluctuations of the residual limb, a conventional, laminated thermoplastic socket fitting was not feasible. Findings and Outcomes: An adjustable, modular socket design was trialled. The residual limb volume fluctuations were accommodated within the socket. Amputee rehabilitation could be continued, and the rehabilitation goals were achieved. The patient was able to wear the prosthesis for 8 h daily and to walk unaided indoors and outdoors. Conclusion: An adjustable, modular socket design accommodated the daily residual limb volume fluctuations and provided a successful outcome in this case. It demonstrates the complexities of socket fitting and design with volume fluctuations. Clinical relevance Ongoing complex regional pain syndrome symptoms within the residual limb can lead to fitting difficulties in a conventional, laminated thermoplastic socket due to volume fluctuations. An adjustable, modular socket design can accommodate this and provide a successful outcome.


2020 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Alexander S. Dickinson ◽  
Maggie K. Donovan-Hall ◽  
Sisary Kheng ◽  
Ky Bou ◽  
Auntouch Tech ◽  
...  