Finite element micro-modelling of a human ankle bone reveals the importance of the trabecular network to mechanical performance: New methods for the generation and comparison of 3D models

2013 ◽  
Vol 46 (1) ◽  
pp. 200-205 ◽  
Author(s):  
W.C.H. Parr ◽  
U. Chamoli ◽  
A. Jones ◽  
W.R. Walsh ◽  
S. Wroe
2014 ◽  
Vol 635-637 ◽  
pp. 507-510
Author(s):  
Dong Peng Du ◽  
Zhe Wu ◽  
Juan Xing ◽  
Xiao Yan Gong ◽  
Xiang Wen Miu ◽  
...  

When strong exercise on human being body, respectively, under knees 30°, 60°,90°, using PRO/E5.0 software to establish the transverse patella fracture and anti-shearing force patella claws 3D models, then the two structure models were assembled and imported into ABAQUS10.1 software to establish the finite element model of patellar fracture fixed within patella claw, and analyzed the mechanical performance in perforce finite element model. Under the same boundary conditions, the maximum displacement and deformation of each components were different at every flexion angle. Compared with anti-shearing force patella claw and AO tensile force girdle, the patella claw with stronger resistance to tension and anti-shearing force was more stable. Deformation and displacement of patella claw in accordance with biomechanical research result that is needed by clinical. Its stability will satisfy clinical requirements for functional exercise.


2019 ◽  
Vol 16 (161) ◽  
pp. 20190674 ◽  
Author(s):  
Nuria Melisa Morales-García ◽  
Thomas D. Burgess ◽  
Jennifer J. Hill ◽  
Pamela G. Gill ◽  
Emily J. Rayfield

Finite-element (FE) analysis has been used in palaeobiology to assess the mechanical performance of the jaw. It uses two types of models: tomography-based three-dimensional (3D) models (very accurate, not always accessible) and two-dimensional (2D) models (quick and easy to build, good for broad-scale studies, cannot obtain absolute stress and strain values). Here, we introduce extruded FE models, which provide fairly accurate mechanical performance results, while remaining low-cost, quick and easy to build. These are simplified 3D models built from lateral outlines of a relatively flat jaw and extruded to its average width. There are two types: extruded (flat mediolaterally) and enhanced extruded (accounts for width differences in the ascending ramus). Here, we compare mechanical performance values resulting from four types of FE models (i.e. tomography-based 3D, extruded, enhanced extruded and 2D) in Morganucodon and Kuehneotherium . In terms of absolute values, both types of extruded model perform well in comparison to the tomography-based 3D models, but enhanced extruded models perform better. In terms of overall patterns, all models produce similar results. Extruded FE models constitute a viable alternative to the use of tomography-based 3D models, particularly in relatively flat bones.


2019 ◽  
Vol 20 (01) ◽  
pp. 1950079
Author(s):  
MATTHEW JIAN-QIAO PENG ◽  
HONGWEN XU ◽  
HAI-YAN CHEN ◽  
XIANGYANG JU ◽  
YONG HU ◽  
...  

Little is known about why and how biomechanics govern the hypothesis that three-Lag-Screw (3LS) fixation is a preferred therapeutic technique. A series models of surgical internal-fixation for femoral neck fractures of Pauwells-II will be constructed by an innovative approach of finite element so as to determine the most stable fixation by comparison of their biomechanical performance. Seventeen sets of CT scanned femora were imported onto Mimics extracting 3D models; these specimens were transferred to Geomagic Studio for a simulative osteotomy and kyrtograph; then, they underwent UG to fit simulative solid models; three sorts of internal fixators were expressed virtually by Pro-Engineer. Processed by Hypermesh, all compartments were assembled onto three systems actually as “Dynamic hip screw (DHS), 3LS and DHS+LS”. Eventually, numerical models of Finite Elemental Analysis (FEA) were exported to AnSys for solution. Three models for fixtures of Pauwells-II were established, validated and analyzed with the following findings: Femoral-shaft stress for [Formula: see text](3LS) is the least; Internal-fixator stress (MPa) for [Formula: see text]; Integral stress (MPa) for [Formula: see text]; displacement of femoral head (mm) for a[Formula: see text](DHS+LS) = 0.735; displacement of femoral shaft (mm) for [Formula: see text]; and displacement of fixators for [Formula: see text]. Mechanical comparisons for other femoral parks are insignificantly different, and these data can be abstracted as follows: the stress of 3LS-system was checked to be the least, and an interfragmentary displacement of DHS+LS assemblages was assessed to be the least”. A 3LS-system should be recommended to clinically optimize a Pauwells-II facture; if treated by this therapeutic fixation, breakage of fixators or secondary fracture is supposed to occur rarely. The strength of this study is that it was performed by a computer-aided simulation, allowing for design of a preoperative strategy that could provide acute correction and decrease procedure time, without harming to humans or animals.


1978 ◽  
Vol 100 (2) ◽  
pp. 356-362 ◽  
Author(s):  
J. S. Porowski ◽  
W. J. O’Donnell

Methods for performing finite element stress analysis of perforated plates under pressure and complex thermal loading conditions are described. The concept of the equivalent solid material of anisotropic properties is employed to define the elasticity matrices to be used for axisymmetric analysis of plates containing triangular and square patterns of circular holes. Generalized plane strain effective elastic constants are used for better approximation of the overall plate behavior. New methods and curves for obtaining local ligament stresses from the nominal stresses in the equivalent solid material are given.


2021 ◽  
Author(s):  
Junqing Xue ◽  
Dong Xu ◽  
Yufeng Tang ◽  
Bruno Briseghella ◽  
Fuyun Huang ◽  
...  

<p><br clear="none"/></p><p>The vulnerability problem of expansion joints could be fundamentally resolved using the concept of jointless bridges. The longitudinal deformation of the superstructure can be transferred to the backfill by using the approach slab. The flat buried approach slab (FBAS) has been used in many jointless bridges in European countries. In order to understand the mechanical performance of FBAS and soil deformation, a finite element model (FEM) was implemented in PLAXIS. Considering the friction between the FBAS and soil, the buried depth, the FBAS length and thickness as parameters, a parametric analysis was carried out. According to the obtained results and in order to reduce the soil deformation above the FBAS, it is suggested to increase the friction between the FBAS and sandy soil, and the buried depth of FBAS. Moreover, it should be paid attention to the vertical soil deformation and the concrete tensile stress of FBAS in pulling condition.</p>


2019 ◽  
Vol 103 (9-10) ◽  
pp. 493-504
Author(s):  
Matthew Jian-Qiao Peng ◽  
Xiangyang Ju ◽  
Hai-Yan Chen ◽  
Bai Bo ◽  
XinXu Li

Purpose: A series models of surgical internal fixation for femoral neck fracture of Pauwels II will be constructed by an innovative approach of finite element so as to determine the most stable fixation by comparison of their biomechanical performance. Method: Seventeen specimens of proximal femurs scanned by computed tomography in Digital Imaging and Communications in Medicine (DICOM) format were input onto Mimics rebuilding 3D models; their stereolithography (STL) format dataset were imported into Geomagic Studio (3D Systems, Rock Hill, South Carolina) for simulative osteotomy and non-uniform rational basis spline kartograph; the generated IGS dataset were interacted by UG to fit simulative 3D-solid models; 3 sorts of internal fixators were expressed in 3D model by ProE (PTC, Boston, Connecticut) program virtually. Processed by HyperMesh (Altair, Troy, Michigan), all compartments (fracture model + internal immobilization) were assembled onto 3 systems actually as: Dynamic hip screw (DHS) / Lag screw (LS) / DHS+LS. Eventually, a numerical model of finite elemental analysis was exported to ANSYS for solution. Result: Three models of internal fixations for femoral neck fracture of Pauwels II were established and validated effectively, the stress and displacement of each internal pin were analyzed, the advantages of each surgical therapy for femoral neck fracture of Pauwels II were compared and demonstrated synthetically as: “The contact stress of 3-LS-system was checked to be the least; the interfragmentary displacement of DHS+1-LS assemblages was assessed to be the least.” Conclusion: 3-LS-system is recommended to be a clinical optimization for Pauwels II femoral neck facture, by this therapeutic fixation mechanically, breakage of fixators, or secondary fracture rarely occurs.


2021 ◽  
Vol 2101 (1) ◽  
pp. 012059
Author(s):  
Z J Yang ◽  
X Li ◽  
G C Li ◽  
S C Peng

Abstract Hollow concrete-filled steel tubular (CFST) member is mainly adopted in power transmission and transformation structures, but when it is used in the superstructure with complex stress, the hollow CFST member has a low bearing capacity and is prone to brittle failure. To improve the mechanical performance of hollow CFST members, a new type of reinforced hollow high strength concrete-filled square steel tube (RHCFSST) was proposed, and its axial compression performance was researched. 18 finite element analysis (FEA) models of axially loaded RHCFSST stub columns were established through FEA software ABAQUS. The whole stress process of composite columns was studied, and parametric studies were carried out to analyze the mechanical performance of the member. Parameters of the steel strength, steel ratio, deformed bar and sandwich concrete strength were varied. Based on the simulation results, the stress process of members can be divided into four stages: elastic stage, elastoplastic stage, descending stage and gentle stage. With the increase of steel strength, steel ratio, the strength of sandwich concrete and the addition of deformed bars, the ultimate bearing capacity of members also increases. Additionally, the increment of those parameters will improve the ductility of the member, except for the sandwich concrete strength.


Author(s):  
Morshed Khandaker ◽  
Onur Can Kalay ◽  
Fatih Karpat ◽  
Amgad Haleem ◽  
Wendy Williams ◽  
...  

Abstract A method to improve the mechanical fixation of a total knee replacement (TKR) implant is clinically important and is the purpose of this study. More than one million joint replacement procedures are performed in people each year in the United States, and experts predict the number to increase six-fold by the year 2030. Whether cemented or uncemented, joint prostheses may destabilize over time and necessitate revision. Approximately 40,000 hip arthroplasty surgeries have to be revised each year and the rate is expected to increase by approximately 140% (and by 600% for total knee replacement) over the next 25 years. In veterinary surgery, joint replacement has a long history and the phenomenon of surgical revision is also well recognized. For the betterment of both people and animals, improving the longevity of arthroplasty devices is of the utmost clinical importance, and towards that end, several strategies are under investigation. One approach that we explore in the present research is to improve the biomechanical performance of cemented implant systems by altering the implant surface architecture in a way that facilitates its cement bonding capacity. Beginning with the Charnley system, early femoral stems were polished smooth, but a number of subsequent designs have featured a roughened surface — created with bead or grit blasting — to improve cement bonding. Failure at the implant-cement interface remains an issue with these newer designs, leading us to explore in this present research an alternate, novel approach to surface alteration — specifically, laser microgrooving. This study used various microgrooves architectures that is feasible using a laser micromachining process on a tibia tray (TT) for the goat TKR. Developing the laser microgrooving (LM) procedure, we hypothesized feasibility in producing parallel microgrooves of precise dimensions and spacing on both flat and round metallic surfaces. We further hypothesized that laser microgrooving would increase surface area and roughness of the cement interface of test metallic implants and that such would translate into an improved acute mechanical performance as assessed in vitro under both static and cyclic loads. The objective was to develop a computational model to determine the effect of LIM on the tibial tray to the mechanical stimuli distributions from implant to bone using the finite element method. This study designed goat TT 3D solid model from a computer topography (CT) images, out of which three different laser microgrooves were engraved on TT sample by varying depth, height and space between two adjacent grooves. The simulation test results concluded that microgrooves acchitecures positively influence microstrain behavior around the implant/bone interfaces. There is a higher amount of strain observed for microgroove implant/bone samples compared to non-groove implant/bone samples. Thus, the laser-induced microgrooves have the potential to be used clinically in TKR components.


Author(s):  
Olivier Rollot ◽  
Maurice Pendola ◽  
Maurice Lemaire ◽  
Igor Boutemy

Abstract This text sums up a research for the French Electric Company, EDF, which wants to know the influence of the temperature variability on the reliability of some of their boilers. These boilers are very complex structures whose behavior has to be modelized by the Finite Element Method, FEM. This work is an application of Finite Element Methods in a reliability context, that means the introduction of random data into a classical FEM, in order to determine the reliability of the structures. These random data may concern geometry, material characteristics of the structures or the loads the structure may carry. Then, it’s necessary to employ new methods to take into account these stochastic approaches and to obtain more efficient decision’s elements for a better control of the boilers.


Sign in / Sign up

Export Citation Format

Share Document