scholarly journals Difference in hemodynamic and wall stress of ascending thoracic aortic aneurysms with bicuspid and tricuspid aortic valve

2013 ◽  
Vol 46 (10) ◽  
pp. 1729-1738 ◽  
Author(s):  
Salvatore Pasta ◽  
Antonino Rinaudo ◽  
Angelo Luca ◽  
Michele Pilato ◽  
Cesare Scardulla ◽  
...  
2018 ◽  
Vol 156 (2) ◽  
pp. 492-500 ◽  
Author(s):  
Yue Xuan ◽  
Zhongjie Wang ◽  
Raymond Liu ◽  
Henrik Haraldsson ◽  
Michael D. Hope ◽  
...  

2021 ◽  
Vol 5 (sup1) ◽  
pp. 14-14
Author(s):  
Axel O. Gomez ◽  
Zhongjie Wang ◽  
Yue Xuan ◽  
Liang Ge ◽  
Elaine E. Tseng

Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
Axel Gomez ◽  
Zhongjie Wang ◽  
Yue XUAN ◽  
Liang Ge ◽  
Elaine E Tseng

Introduction: Ascending thoracic aortic aneurysms (aTAAs) carry a risk of dissection. Elective repair guidelines are designed around size thresholds, but the one-dimensional parameter is insufficient to predict acute events in small aneurysms. Biomechanically, aortic events can occur when wall stress exceeds wall strength. Patient-specific aTAA wall stresses may be a better predictor of complications. Our aim was to compare wall stresses in aTAAs associated with a tricuspid aortic valve (TAV) based on diameter. Methods: Patients with TAV-aTAA and diameter >4.0cm (n=448) were divided into groups by 0.5 cm diameter increments. Pre-stress three-dimensional aneurysm geometries were reconstructed from ECG-gated computer tomography images. A fiber-embedded hyperelastic material model was applied to obtain longitudinal and circumferential wall stress distributions under systolic pressure. Medians with interquartile ranges are reported. The Kruskal-Wallis test is used for comparisons between size groups. Results: Peak longitudinal wall stresses for TAV-aTAA were 308[282-338] kPa for size 4.0-4.4cm vs 341[309-362] kPa for 4.5-4.9cm vs 339[289-370] kPa for 5.0-5.4cm vs 319[297-355] kPa for 5.5-5.9cm vs 373[364-449] for 6.0cm (p=0.003). Peak circumferential wall stresses were 487[448-579] kPa for size 4.0-4.4cm vs 516[473-619] kPa for 4.5-4.9cm vs 506[422-580] kPa for 5.0-5.4cm vs 540[468-591] kPa for 5.5-5.9cm vs 565[506-634] for >6.0cm (p=0.19) (figure). 95th-percentile longitudinal peak stress for TAV-aTAA <5.5cm vs ≥5.5cm is 408 vs 465 kPa. Conclusions: Longitudinal wall stresses are higher as diameter increases. The 95% percentile longitudinal peak stress for diameter ≥5.5cm is ~450 kPa, which correlates with established ~5% dissection risk for size ≥5.5cm. Wall stress thresholds may be a better predictor of patient-specific risk of dissection than diameter and require testing in clinical trials.


2020 ◽  
Vol 110 (3) ◽  
pp. 807-814 ◽  
Author(s):  
Axel Gomez ◽  
Zhongjie Wang ◽  
Yue Xuan ◽  
Andrew D. Wisneski ◽  
Michael D. Hope ◽  
...  

Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
Siddharth K Prakash ◽  
Angela T Yetman ◽  
Hector I Michelena ◽  
Malenka M Bissell ◽  
Yuli Y Kim ◽  
...  

Introduction: Bicuspid Aortic Valve (BAV), the most common congenital heart defect, is a major cause of aortic regurgitation or stenosis requiring valve replacement and thoracic aortic aneurysms predisposing to acute aortic dissections (TAD). The spectrum of BAV ranges from severe early onset valve and aortic complications to sporadic late onset disease. Hypothesis: Early onset BAV (EBAV) cases with valve or aortic complications that require intervention prior to age 30 are enriched for rare genetic variants that cause BAV and TAD. Methods: We performed whole exome sequencing of 147 EBAV cases in 141 families who were enrolled in the UTHealth Bicuspid Aortic Valve Research Registry. Candidate variants in the EBAV cohort (26% female, mean age 18, 44% with TAD) were compared to unselected controls from the Genome Aggregation Database (gnoMAD) and the Database of Genotypes and Phenotypes (dbGAP). We considered variants with minor allele frequencies (MAF) < 1%, Combined Annotation Dependent Depletion (CADD) scores > 25, and damaging (Polyphen-2) or deleterious (SIFT) functional prediction scores. Genomic copy number variants (CNVs) were detected using CoNIFER and prioritized when deletions involved genes with probability of loss intolerance (pLI) > 0.9. Variants were validated using quantitative PCR or Sanger sequencing. Results: We identified 6 rare variants of USP10 in 6 EBAV families (4% of cohort): 4 CNVs (2 duplications and 2 deletions) that are rare in dbGAP controls (4 in 15,414) and 2 deleterious rare missense variants (MAF<5x10 -5 in gnoMAD). Two of the 4 CNVs were de novo events in trios. In contrast, rare deleterious variants of the known causal BAV genes NOTCH1 (1), ROBO4 (1), GATA4 (1), GATA5 (1), and SMAD6 (4) were found in 7 total families. USP10 encodes a ubiquitin peptidase that is required for endothelial Notch signaling during vascular development. Conclusions: We identified rare and de novo variants of USP10 that implicate USP10 as a new candidate gene for BAV.


2016 ◽  
Vol 66 (04) ◽  
pp. 278-286 ◽  
Author(s):  
Shiho Naito ◽  
Mathias Hillebrand ◽  
Alexander Bernhardt ◽  
Annika Jagodzinski ◽  
Lenard Conradi ◽  
...  

AbstractTraditional risk stratification model of bicuspid aortic valve (BAV) aortopathy is based on measurement of maximal cross-sectional aortic diameter, definition of proximal aortic shape, and aortic stiffness/elasticity parameters. However, conventional imaging-based criteria are unable to provide reliable information regarding the risk stratification in BAV aortopathy, especially considering the heterogeneous nature of BAV disease. Given those limitations of conventional imaging, there is a growing clinical interest to use circulating biomarkers in the screening process for thoracic aortic aneurysms as well as in the risk-assessment algorithms. We aimed to systematically review currently available biomarkers, which may be of value to predict the natural evolution of aortopathy in individuals with BAV.


Sign in / Sign up

Export Citation Format

Share Document