Voltammetric behavior of I2/2I− redox system on boron-doped diamond electrode in various media and its utilization for the indirect detection of tin(II)

2015 ◽  
Vol 758 ◽  
pp. 46-53 ◽  
Author(s):  
Zuzana Chomisteková ◽  
Eva Culková ◽  
Ján Vojtko ◽  
Roman Brescher ◽  
Peter Tomčík
2012 ◽  
Vol 31 (2) ◽  
pp. 195 ◽  
Author(s):  
Sachin Saxena ◽  
Ratnanjali Shrivastava ◽  
Soami P. Satsangee

The electrochemical behavior of the asthma drug doxofylline was studied at a boron-doped diamond electrode in BR buffer (pH 3.8) by square-wave voltammetry. Cyclic voltammetry revealed the oxidation of doxofylline as an irreversible diffusion-controlled process. The oxidation mechanism was proposed and the drug was studied in the presence of solubilized systems like Tween-20 (T-20), sodium dodecyl sulfate (SDS), Triton X-100 (TTN), dioxane (DO), dimethylformamide (DMF), diethyl ether (DEE), benzene and methanol (MeOH). Comparison of the current responses in the solution system explained the sensitivity of the boron-doped diamond electrode (BDDE) with a three-fold increase in the current value compared to that of a glassy carbon electrode (GCE) at a fixed concentration of doxofylline. Peak current values varied linearly with increasing concentration and the LOD and LOQ were found to be 3.48 and 10.56 µg/ml, respectively. This method was employed to investigate doxofylline in the pharmaceutical formulation.


2019 ◽  
Vol 93 ◽  
pp. 50-53 ◽  
Author(s):  
Naoki Kamoshida ◽  
Seiji Kasahara ◽  
Norihito Ikemiya ◽  
Nagahiro Hoshi ◽  
Masashi Nakamura ◽  
...  

2013 ◽  
Vol 11 (10) ◽  
pp. 1674-1681 ◽  
Author(s):  
Pınar Pınar ◽  
Yavuz Yardım ◽  
Zühre Şentürk

AbstractThis paper examined for the first time, the possibilities of the usage of a boron-doped diamond electrode for the redox behavior of rutin using cyclic and adsorptive stripping voltammetry. The cyclic voltammograms showed a pair of redox peaks at lower potentials followed by an irreversible oxidation peak at higher positive potential. Using square-wave adsorptive stripping voltammetry, the compound yielded a well-defined voltammetric response in Britton-Robinson buffer, pH 4.0 at +0.48 V (vs. Ag/AgCl) (after 60 s accumulations at a fixed potential of 0.2 V). The calibration curve was linear in the concentration range from 0.01 µg mL−1 to 0.1 µg mL−1 (1.64×10−8 M − 1.64×10−7 M). A detection limit of 0.0017 µg mL−1 (2.78×10−9 M) was observed without any chemical modifications and electrochemical surface pretreatments. As an example, the practical applicability of boron-doped diamond electrode was tested with the measurement of rutin in dietary supplement products.


2005 ◽  
Vol 17 (3) ◽  
pp. 269-274 ◽  
Author(s):  
Murilo S�rgio?da?Silva?Juli�o ◽  
�rica?Cristina Almeida ◽  
Mauro Aquiles?La?Scalea ◽  
Neiden�i?Gomes Ferreira ◽  
Richard?G. Compton ◽  
...  

2013 ◽  
Vol 25 (7) ◽  
pp. 1734-1741 ◽  
Author(s):  
Ana Paula Pires Eisele ◽  
Débora Nóbile Clausen ◽  
César Ricardo Teixeira Tarley ◽  
Luiz Henrique Dall'Antonia ◽  
Elen Romão Sartori

Sign in / Sign up

Export Citation Format

Share Document