scholarly journals Attenuation mechanisms and key parameters to enhance treatment performance in vegetation filters: A review

2021 ◽  
Vol 300 ◽  
pp. 113752
Author(s):  
R. Pradana ◽  
J.A. Hernández-Martín ◽  
V. Martínez-Hernández ◽  
R. Meffe ◽  
A. de Santiago-Martín ◽  
...  
2010 ◽  
Author(s):  
Benjamin C. Campbell ◽  
Gantt Galloway ◽  
Quyen Q. Tiet

2005 ◽  
Vol 54 (6) ◽  
pp. 385-395 ◽  
Author(s):  
Christopher W. K. Chow ◽  
Rolando Fabris ◽  
Mary Drikas ◽  
Michael Holmes

2000 ◽  
Vol 41 (1) ◽  
pp. 69-72 ◽  
Author(s):  
S.Ç. Ayaz ◽  
I. Akca

The constructed wetland is a low-cost technology to control environmental pollution. The system is especially suitable for small settlements. An innovative constructed wetland technology is described in this paper. A pilot plant was used to assess the performance of the system. The experimental system consists of two serial connected tanks that settled up with fillers and Cyperus as treatment media. Wastewater is recycled periodically upward and downward between the two tanks. The treatment performance was monitored in different loading conditions in a one-year period. The average COD removal efficiency of 90% was observed at 122 g COD/m2.day average loading conditions. Other average removal values in the same conditions are as follows: suspended solid 95%, TKN 77%, total nitrogen 61%, PO4-P 39%. The land requirement for this system will be 0.82 m2 per capita when applying as full-scale system.


2012 ◽  
Vol 7 (1) ◽  
Author(s):  
S. S. Fatima ◽  
S. Jamal Khan

In this study, the performance of wastewater treatment plant located at sector I-9 Islamabad, Pakistan, was evaluated. This full scale domestic wastewater treatment plant is based on conventional activated sludge process. The parameters which were monitored regularly included total suspended solids (TSS), mixed liquor suspended solids (MLSS), mixed liquor volatile suspended solids (MLVSS), biological oxygen demand (BOD), and chemical oxygen demand (COD). It was found that the biological degradation efficiency of the plant was below the desired levels in terms of COD and BOD. Also the plant operators were not maintaining consistent sludge retention time (SRT). Abrupt discharge of MLSS through the Surplus Activated sludge (SAS) pump was the main reason for the low MLSS in the aeration tank and consequently low treatment performance. In this study the SRT was optimized based on desired MLSS concentration between 3,000–3,500 mg/L and required performance in terms of BOD, COD and TSS. This study revealed that SRT is a very important operational parameter and its knowledge and correct implementation by the plant operators should be mandatory.


Sign in / Sign up

Export Citation Format

Share Document