Effect from Cyclic Fatigue of Nickel-Titanium Rotary Files on Torsional Resistance

2012 ◽  
Vol 38 (4) ◽  
pp. 527-530 ◽  
Author(s):  
Ju-Yeong Kim ◽  
Gary Shun-Pan Cheung ◽  
Se-Hee Park ◽  
Dae-Cheol Ko ◽  
Jin-Wook Kim ◽  
...  
2012 ◽  
Vol 38 (4) ◽  
pp. 541-544 ◽  
Author(s):  
Hyeon-Cheol Kim ◽  
Sang-Won Kwak ◽  
Gary Shun-Pan Cheung ◽  
Dae-Hoon Ko ◽  
Se-Min Chung ◽  
...  

2020 ◽  
Vol 10 (16) ◽  
pp. 5604 ◽  
Author(s):  
Gianluca Gambarini ◽  
Andrea Cicconetti ◽  
Dario Di Nardo ◽  
Gabriele Miccoli ◽  
Alessio Zanza ◽  
...  

Protaper Universal (PTU), Protaper Gold (PTG) (Maillefer, Ballaigues, CH), EdgeTaper (ET), and EdgeTaper Platinum (ETP) (Albuquerque, NM, USA) were tested for both torsional and flexural resistance. The aim of the present study was to evaluate the influence of proprietary heat treatment on the metallurgical properties of the aforementioned instruments. Four groups of 30 different instruments (size 20.07) were tested, then divided into two subgroups of 15 instruments—one for the cyclic fatigue test in a curved canal (90°—2 mm radius) at 300 rpm and 2.5 Ncm. The time to fracture (TtF) and fragment length (FL) were recorded. The other subgroup was subjected to the torsional test (300 rpm, 5.5 Ncm). The torque to fracture and TtF were recorded. All the instruments underwent a SEM analysis. The heat-treated instruments showed a significantly higher fatigue resistance than the non-heat-treated instruments (p < 0.05). No significant differences were found in the torsional resistance between the ET and PTU, and the ETP and PTG. However, when comparing all the groups, the heat-treated instruments showed less torsional resistance. The improvement from heat treatment was mainly found in the cyclic fatigue resistance.


2021 ◽  
Vol 19 ◽  
pp. 228080002098740
Author(s):  
Haiyun Liu ◽  
Yanfeng Li ◽  
Guangquan Chai ◽  
Yuan Lv ◽  
Changjian Li ◽  
...  

Objective: To evaluate the effect of synchronous water irrigation on the fatigue resistance of nickel-titanium instrument. Methods: A standardized cyclic fatigue test models were established, and five types of nickel-titanium instruments (PTU F1, WO, WOG, RE, and M3) were applied. Each instrument was randomly divided into two groups ( N = 12). There was synchronous water irrigation in the experimental group, and no water irrigation in the control group. Besides, ProTaper Universal F1 was randomly divided into 10 groups ( N = 20). In the static group, nickel-titanium instruments were divided into one control group (no irrigation, N = 20) and six experimental group (irrigation, N = 20) based on different flow rate, angle and position; while in the dynamic group, instruments were divided into one control group (no irrigation, N = 20) and two experimental group (irrigation, N = 20) based on different flow rate. The rotation time (Time to Failure, TtF) of instruments was recorded and analyzed. Results: According to the static experiments, the TtF of instruments in all experimental groups was significantly higher than that in the static control group. Besides, the dynamic tests of PTU F1 showed that the TtF in the experimental group was significantly higher than that in the dynamic control group. Compared with control group, the TtF in the experimental groups increased by at least about 30% and up to 160%. The static and dynamic tests of PTU F1 showed that the TtF of nickel-titanium instrument in all experimental groups was significantly higher than that in the control group. However, there was no significant difference between any two experimental groups. Conclusion: Regardless of dynamic or static model, TtF with irrigation was longer than that with non-irrigation, indicating that synchronous irrigation can increase the fatigue resistance of nickel-titanium instrument. However, different irrigation conditions may have the same effect on the fatigue resistance.


2019 ◽  
Vol 43 (1) ◽  
Author(s):  
Amira Galal Ismail ◽  
Mohamed Hussein Abdelfattah Zaazou ◽  
Manar Galal ◽  
Nada Omar Mostafa Kamel ◽  
Mohamed Abdulla Nassar

Abstract Background The objective of this study was to assess the bending and torsional properties of two nickel-titanium endodontic files with equivalent sizes and various designs and alloys using finite element analysis, ProTaper Next®X2 (PTN) size 25 with 0.06 taper and WaveOne Gold® (WOG) primary size 25 with 0.07 taper. Methodology Two-dimensional models of the two files PTN and WOG were created using computer tomography scanning and stereomicroscope to produce a three-dimensional digital model. Instrument behavior under bending or torsional conditions was numerically analyzed in SolidWorks software package. Result ProTaper Next® revealed higher flexibility than WaveOne Gold® when exposed to cantilever bending but showed higher stress accumulation than WOG. In terms of torsional resistance, PTN also revealed higher torsional resistance than WOG. Conclusion The geometry of the instrument, thermomechanical treatment of the alloy, and its composition affect the mechanical behavior (bending and torsion) of nickel titanium rotary files. Hence, being aware of these behavioral differences, each clinician will be able to use the adequate file according to the clinical situation in addition to the manufacturer’s instructions.


Author(s):  
Giusy Rita Maria La Rosa ◽  
Carlotta Palermo ◽  
Sebastiano Ferlito ◽  
Gaetano Isola ◽  
Francesco Indelicato ◽  
...  

2018 ◽  
Vol 12 (4) ◽  
pp. 283-287 ◽  
Author(s):  
Gülşah Uslu ◽  
Taha Özyürek ◽  
Mustafa Gündoğar ◽  
Koray Yılmaz

Background. The aim of this study was to compare the cyclic fatigue resistance of 2Shape, Twisted File (TF) and EndoSequence Xpress (ESX) nickel-titanium rotary files at intracanal temperature (35°C). Methods. Twenty 2Shape TS1 (25/.04), 20 TF (25/.04) and 20 ESX (25/.04) files were tested for cyclic fatigue at intracanal temperature (35°C). All the instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, 60° angle of curvature and a radius curvature of 5 mm until fracture occurred; the time to fracture was recorded in seconds using a digital chronometer and the number of cycles to fracture (NCF) for each file was calculated. Kruskal-Wallis test with Bonferroni correction was performed to statistically analyze data using SPSS 21.0. Statistical significance was set at P<0.05. Results. NCF values revealed that the 2Shape had significantly the highest cyclic fatigue resistance, followed by TF and ESX at intracanal temperature (P<0.05). The difference was significant between the TF and ESX groups (P<0.05). There was no significant difference among the 2Shape, TF and ESX files with respect to the lengths of the fractured file fragments (P>.05). Conclusion. Within the limitations of present study, it was concluded that the cyclic fatigue resistance of 2Shape files at the intracanal temperature is higher than that of TF and ESX files.


Author(s):  
Jader Camilo Pinto ◽  
Fernanda Ferrari Esteves Torres ◽  
Airton Oliveira Santos-Junior ◽  
Marco Antonio Hungaro Duarte ◽  
Juliane Maria Guerreiro-Tanomaru ◽  
...  

Abstract Objective The aim of this study was to investigate the effect of additional apical preparation using the ProDesign Logic (PDL) 50/.01 rotary heat-treated nickel–titanium (NiTi) file with a larger diameter and minimal taper for retreatment of curved root canals. Materials and Methods Mesial curved root canals of 12 mandibular molars were prepared using PDL 25/.06 and filled using the continuous wave of condensation technique and AH Plus sealer. After retreatment using ProDesign S (PDS) 25/.08, PDL 25/.06 and PDL 35/05, a complementary procedure was performed with PDL 50/.01. Microcomputed tomography (micro-CT) scanning was performed before and after retreatment procedures. The cyclic fatigue resistance of unused PDS 25/.08, PDL 25/.06, PDL 35/.05 and PDL 50/.01 instruments (n = 12) was evaluated in a stainless-steel device. Statistical Analysis Data on the volumes of the root canals and the remaining filling materials were submitted to the paired t-test. Cyclic fatigue resistance data was submitted to one-way ANOVA and Tukey’s tests (α = 0.05). Results Use of PDL 50/.01 decreased the remaining filling materials in the apical third (p < 0.05). The root canal volume was similar in the cervical and middle thirds before and after preparation using PDL 50/.01 (p > 0.05). PDL 50/.01 presented the highest cyclic fatigue resistance (p < 0.05). Conclusions Use of the PDL 50/.01 instrument as an additional apical preparation for retreatment of curved root canals improved filling material removal in the apical third, while maintaining the dentin in the cervical and middle thirds. In addition, PDL 50/.01 presented high-flexural resistance.