M sub-shell X-ray fluorescence cross-section measurements for six elements in the range Z = 78–92 at tuned synchrotron photon energies 5, 7 and 9 keV.

Author(s):  
Himani Bansal ◽  
M.K. Tiwari ◽  
Raj Mittal
1988 ◽  
Vol 17 (2) ◽  
pp. 53-54 ◽  
Author(s):  
Anita Rani ◽  
Rajesh K. Koshal ◽  
S. N. Chaturvedi ◽  
N. Nath

2008 ◽  
Vol 86 (2) ◽  
pp. 361-367 ◽  
Author(s):  
I Han ◽  
M Şahin ◽  
L Demir

Kα, Kβ, Lα, and Lβ X-ray fluorescence cross sections for lanthanides in the atomic range 62 ≤ Z ≤ 68 (Sm, Eu, Gd Tb, Dy, Ho, and Er) were simultaneously measured by 59.54 keV incident photon energy at five angles ranging from 120° to 160°. The measurements were performed using an Am-241 radioisotope as the photon source and a Si(Li) detector. The Lα X-ray fluorescence cross section (σLα) was found to decrease with increasing emission angle and showed an anisotropic distribution of Lα X-rays. Kα, Kβ, and Lβ X-ray fluorescence cross sections (σKα, σKβ, and σLβ) were observed to be angle-independent and showed an isotropic distribution of Kα, Kβ, and Lβ X-rays. The Kα and Kβ X-rays originate from filling of the K shell (J = 1/2) vacancies, Lβ X-rays from filling of the L1 and L2 (J = 1/2) subshell vacancies, and Lα X-rays from filling of the L3 subshell (J = 3/2) vacancy. The fluorescent X-rays originating from the vacancy states with J = 1/2 are isotropic and unpolarized, but fluorescent X-rays originating from the vacancy states with J > 1/2 are anisotropic and polarized. Thus, the atomic inner shells vacancy states with J > 1/2 are aligned whereas vacancy states with J = 1/2 are not aligned. Lα fluorescence X-rays have an anisotropic distribution, while Kα, Kβ, and Lβ fluorescence X-rays have isotropic distribution. Furthermore, the IKβ/IKα, ILα/IKα}, ILβ/IKα, and ILβ/ILα intensity ratios for the elements under investigation were determined. The experimental cross sections and intensity ratios for Kα, Kβ, Lα, and Lβ fluorescence X-rays were also determined, and these experimental values were compared with our calculated theoretical values.PACS Nos.: 32.30.Rj, 32.80.Cy


2014 ◽  
Vol 5 (2) ◽  
pp. 363-369 ◽  
Author(s):  
Sheenu Gupta ◽  
Gurpreet Kaur ◽  
Himani Bansal ◽  
Vijay Kumar Mittal ◽  
Raj Mittal

1990 ◽  
Vol 19 (3) ◽  
pp. 155-158 ◽  
Author(s):  
Surinder Singh ◽  
Rakesh Rani ◽  
Devinder Mehta ◽  
Nirmal Singh ◽  
P. C. Mangal ◽  
...  

Author(s):  
Thomas S. Leeson ◽  
C. Roland Leeson

Numerous previous studies of outer segments of retinal receptors have demonstrated a complex internal structure of a series of transversely orientated membranous lamellae, discs, or saccules. In cones, these lamellae probably are invaginations of the covering plasma membrane. In rods, however, they appear to be isolated and separate discs although some authors report interconnections and some continuities with the surface near the base of the outer segment, i.e. toward the inner segment. In some species, variations have been reported, such as longitudinally orientated lamellae and lamellar whorls. In cross section, the discs or saccules show one or more incisures. The saccules probably contain photolabile pigment, with resulting potentials after dipole formation during bleaching of pigment. Continuity between the lamina of rod saccules and extracellular space may be necessary for the detection of dipoles, although such continuity usually is not found by electron microscopy. Particles on the membranes have been found by low angle X-ray diffraction, by low temperature electron microscopy and by freeze-etching techniques.


Author(s):  
Shawn Williams ◽  
Xiaodong Zhang ◽  
Susan Lamm ◽  
Jack Van’t Hof

The Scanning Transmission X-ray Microscope (STXM) is well suited for investigating metaphase chromosome structure. The absorption cross-section of soft x-rays having energies between the carbon and oxygen K edges (284 - 531 eV) is 6 - 9.5 times greater for organic specimens than for water, which permits one to examine unstained, wet biological specimens with resolution superior to that attainable using visible light. The attenuation length of the x-rays is suitable for imaging micron thick specimens without sectioning. This large difference in cross-section yields good specimen contrast, so that fewer soft x-rays than electrons are required to image wet biological specimens at a given resolution. But most imaging techniques delivering better resolution than visible light produce radiation damage. Soft x-rays are known to be very effective in damaging biological specimens. The STXM is constructed to minimize specimen dose, but it is important to measure the actual damage induced as a function of dose in order to determine the dose range within which radiation damage does not compromise image quality.


Sign in / Sign up

Export Citation Format

Share Document