Metallurgical failure analysis for a blade failed in a gas-turbine engine of a power plant

2009 ◽  
Vol 30 (8) ◽  
pp. 3121-3125 ◽  
Author(s):  
Zainul Huda
Author(s):  
C. L. Carlson

The major design features of the FT4A gas-turbine engine for marine and industrial applications are described, the development-test history of the engine is reviewed, and the field experience with this and similar engine concepts is discussed. In addition, the particular characteristics of the FT4A power plant which make the latter attractive for various applications are mentioned.


2014 ◽  
Vol 14 (5) ◽  
pp. 578-587 ◽  
Author(s):  
R. K. Mishra ◽  
Johney Thomas ◽  
K. Srinivasan ◽  
Vaishakhi Nandi ◽  
Raghavendra Bhat

2021 ◽  
Vol 15 (2) ◽  
pp. 26-32
Author(s):  
V. A. Gusarov

The authors showed the necessity to develop a rear-wheel drive hybrid mobile agricultural vehicle with electric drive and power plant. (Research purpose) To develop and study a new kinematic scheme of a mobile vehicle based on a self-propelled tractor T-16 chassis, which provides increased reliability, comfortable working conditions for the operator, a significant improvement in the environmental situation, and better economic efficiency. (Materials and methods) The authors listed the advantages of the new hybrid vehicle kinematic scheme. They gave the comparative technical characteristics of a diesel engine and an asynchronous electric motor. They developed a new methodology for calculating gas turbine engine technical parameters and described the production process of an electric drive with a capacity of 11 kilowatts to drive the driving wheels. The authors gave a thermal design of the compressor parameters, turbine. They calculated the excess air ratio. According to the parameters obtained, a K27-145 turbocharger was chosen, which simultaneously served as a turbine and a compressor of a gas turbine engine. A kinematic diagram was created with a gas turbine electric generator, storage batteries, an asynchronous frequency-controlled motor and a mechanical gearbox. (Results and discussion) The authors proposed to use a mobile vehicle as a mobile power plant: an output socket with a voltage of 220-230 volts operated from an inverter connected to batteries; the second socket – with a three-phase voltage of 400 volts – from the generator of the power gas turbine plant. (Conclusions) It was proved that the proposed hybrid mobile vehicle design on a battery and a gas turbine was capable of operating throughout the entire working day, and to provide 16 horsepower of a diesel engine, it was enough to install an asynchronous electric motor with a capacity of 7.5 kilowatts. The authors calculated the compressor performance of the gas turbine engine, which was 0.178 kilograms per second. The geometric parameters of the combustion chamber and the technical characteristics of the turbocharger were determined.


2021 ◽  
Vol 6 (3) ◽  
pp. 33-40
Author(s):  
V. A. Shishkov

increasing the efficiency of the power plant. A method of controlling the supply of cryogenic fuel to a gas turbine engine is to pump its liquid phase, followed by its separation into two parts and controlling the flow rate of each part. Heated the first part of the cryogenic fuel to a gaseous state in the heat exchanger, mixing it with the second part and feeding the resulting mixture of cryogenic fuel into the combustion chamber. The first part of the cryogenic fuel flow rate is passed through the heat exchanger Gta = Gsm [Ср_sm (Тfp + T) il] / [ig il], where Gsm is the consumption of cryogenic fuel at the outlet of the mixer, Ср_sm is the isobaric heat capacity of cryogenic fuel at the outlet from the mixer, Тfp is the temperature of the phase transition of cryogenic fuel from liquid to gas at a pressure in the mixer, T is the temperature of the gas mixture of cryogenic fuel at the outlet of the mixer above the temperature of the phase transition, il is the enthalpy of the first part of the liquid phase of cryogenic fuel at the input ode to the heat exchanger and the second part of the liquid phase of the cryogenic fuel, which is fed to the second entrance to the mixer, ig is the enthalpy of the gaseous phase of the cryogenic fuel at the outlet of the heat exchanger, at which it is fed to the first entrance to the mixer. Moreover, ig Ср_sm (Тfp + T) il and Gsm = Gta + Gl, where Gl is the flow rate of the second part of the liquid phase of the cryogenic fuel, which is fed to the second input to the mixer. When the pressure of the cryogenic fuel in the mixer is below the critical value Pkr, the temperature Тfp of the phase transition from liquid to gas of the cryogenic fuel is taken equal to the temperature Тnas on the saturation line of the cryogenic fuel at the corresponding pressure in the mixer. The excess of the temperature of the cryogenic fuel mixture over the phase transition temperature after mixing the gas and liquid phases at the mixer outlet sets T = 60 ... 170 for cryogenic methane and T = 150 ... 260 for cryogenic hydrogen. Due to the gasification of a part of the cryogenic fuel consumption in the heat exchanger and subsequent mixing of this part with the second liquid part of the cryogenic fuel in the mixer, the freezing of the outer surface of the heat exchanger in all operating modes of the power plant is reduced. Due to the reduction of external freezing of the channels of the heat exchanger, the heat transfer efficiency is increased in it. By reducing the dimensions of the heat exchanger, the hydraulic losses in the gas-dynamic path of the power plant are reduced, which, in turn, increases its efficiency. By lowering the temperature of the gas phase of the cryogenic fuel at the inlet to the combustion chamber, the temperature of the exhaust gases at its outlet is reduced, which, in turn, increased the reliability of the gas turbine of the power plant. The method of operation of the cryogenic fuel supply system is intended for ground-based power plants and vehicles. The work is intended for scientists and designers in the field of cryogenic fuels for internal combustion engines.


2008 ◽  
Vol 15 (8) ◽  
pp. 1111-1129 ◽  
Author(s):  
E. Poursaeidi ◽  
M. Aieneravaie ◽  
M.R. Mohammadi

Sign in / Sign up

Export Citation Format

Share Document