Leak detection monitoring system of long distance oil pipeline based on dynamic pressure transmitter

Measurement ◽  
2014 ◽  
Vol 49 ◽  
pp. 382-389 ◽  
Author(s):  
Yu Zhang ◽  
Shili Chen ◽  
Jian Li ◽  
Shijiu Jin
2012 ◽  
Vol 220-223 ◽  
pp. 1628-1632
Author(s):  
Li Kun Wang ◽  
Bin Xu ◽  
Hong Chao Wang ◽  
Shi Li Chen ◽  
Jia Yong Wu ◽  
...  

Principle of the pipeline leak detection system is presented, and the leak detection method based on acoustic wave and wavelet analysis is studied in this paper. The dynamic pressure transmitter based on piezoelectric dynamic pressure transducer is designed. The characteristic of dynamic pressure transmitter when pipeline leak happened is analyzed. The dynamic pressure signal is suitable for pipeline leak detection for quick-change of pipeline internal pressure, while the static pressure is suitable for slow-change of pipeline internal pressure. The signal is analyzed by wavelet analysis method to detect the singularity, and the singularity is used to recognize and locate the leak. This paper indicated that the dynamic pressure signal could be adjust to this detection that the pressure changes in the pipeline. Field tests in 68.2 km pipeline segment show that the method detects pipeline leak rapidly and precisely.


Author(s):  
Shane Siebenaler ◽  
Eric Tervo ◽  
Paul Vinh ◽  
Chris Lewis

The pipeline industry is improving its ability to detect and locate leaks through emerging technologies. There has been a variety of research in recent years aimed at further development of sensor-based technologies for leak detection. A key obstacle to retrofitting existing pipelines with leak detection technologies is the cost and risk of installing hardware, particularly those sensors that require excavation near the pipe. There are many advantages to employing leak detection systems that can leverage existing instrumentation access locations. One such technology may be negative-wave leak detection systems. Negative-wave technologies work by measuring dynamic pressure changes in the pipe. It should be noted that some negative-wave systems require line modifications to accommodate multiple transmitters. While such systems have been on the market for many years, there is insufficient data available about their performance under various pipeline operating conditions for widespread adoption. In an effort to close many information gaps on the performance envelope of negative-wave technologies, a PRCI-funded field test was performed on a 41-kilometer segment of a 30-inch diameter heavy crude oil pipeline. Products from three suppliers were installed at either end of the test segment. Actual commodity withdrawals were conducted at a remote valve site approximately 21 kilometers into the segment during various operations to test the systems’ abilities to detect the withdrawals without direct user interaction. These test points included withdrawals during steady-state flowing, pump startup, and shutdown conditions. Data were collected from each system to determine their abilities to detect leaks under various conditions, abilities to locate the leak, false alarm rates, and response times. This test provided significant insight into the performance of such systems over the range of conditions tested. The key focus of this paper is the approach for conducting such multi-vendor commodity withdrawals. This project required some unique considerations for its execution. Such considerations are also documented to provide input to others who are considering such a test.


Author(s):  
Likun Wang ◽  
Min Xiong ◽  
Jinyun Zhao ◽  
Hongchao Wang ◽  
Bin Xu ◽  
...  

The dynamic pressure transmitter based on piezoelectric dynamic pressure transducer is designed. The characteristic of dynamic pressure transmitter when pipeline leak happened is analyzed. The dynamic pressure signal is suitable for pipeline leak detection for quick-change of pipeline internal pressure, while the static pressure is suitable for slow-change of pipeline internal pressure. This paper indicated that the dynamic pressure signal could be adjust to this detection that the pressure changes quickly in the pipeline. Field tests show that the proposed method detects pipeline leak rapidly and precisely. The field test in 68.2 km pipeline shows that the least detected leakage ratio with dynamic pressure method is 0.6 percent pipeline throughput and location error is 80 m.


Energy ◽  
2021 ◽  
pp. 121604
Author(s):  
Xuejing Zheng ◽  
Fangshu Hu ◽  
Yaran Wang ◽  
Lijun Zheng ◽  
Xinyong Gao ◽  
...  

2011 ◽  
Vol 301-303 ◽  
pp. 1162-1165
Author(s):  
Fei Hu ◽  
Wen Qing Yin ◽  
Cai Rong Chen

The Greenhouse Temperature Is one of the Key Factors for Controlling the Growth of Crops. Traditional Methods of Temperature Monitoring Can Not Meet the Modern Greenhouse Requirements of High Accuracy, Fast Acquisition and Response. a Greenhouse Temperature Monitoring System Based on MSP430 Was Designed. this System Uses Digital Temperature Sensor DS18B20 to Measure Temperature, MSP430 to Process Data and Transmit Data to the Host Computer through RS485 Bus, Realizing the Real-Time Detection and Long-Distance Transmission of Greenhouse Temperature. this System Has the Features of Simple Structure, Low Power Consumption, Stability and Strong Portability Etc.


Author(s):  
XianYong Qin ◽  
LaiBin Zhang ◽  
ZhaoHui Wang ◽  
Wei Liang

Reliability, sensitivity and detecting time under practical operational conditions are the most important parameters of a leak detection system. With the development of hardware and software, more and more pipelines are installed with advanced SCADA (Supervisory Control and Data Acquisition) system, so the compatibility of the leak detection system with SCADA system is also becoming important today. Pipeline leakage generates a sudden change in the pipeline pressure and flow. The paper introduces leak detecting methods according to the pipeline pressure wave change. In order to improve the compatibility of the leak detecting system, “OPC (Ole for process Control)” technology is used for obtaining the pressure signals from the distributed data collection system. Special focus is given on analysis of the pressure signals. It is successful to denoise the signals by means of wavelet scale shrinkage, and to capture the leak time tag using wavelet transform modulus maximum for locating the leak position accurately. A leak detecting system is established based on SCADA system. Tests and practical applications show that it locates leak position precisely. Good performance is obtained on both crude oil pipeline and product pipeline.


Sign in / Sign up

Export Citation Format

Share Document