Electrochemical and surface analysis studies of 2-(quinolin-2-yl)quinazolin-4(3H)-one as corrosion inhibitor for Q235 steel in hydrochloric acid

2016 ◽  
Vol 222 ◽  
pp. 671-679 ◽  
Author(s):  
Weiwei Zhang ◽  
Rui Ma ◽  
Huanhuan Liu ◽  
Yu Liu ◽  
Shuai Li ◽  
...  
2018 ◽  
Vol 10 (1) ◽  
pp. 102-115
Author(s):  
Cinthia E. B. Maia ◽  
Gilberto A. Romeiro ◽  
Márcia C. C. Veloso ◽  
Mariane F. dos Santos ◽  
Marcos V. da Silva Santana ◽  
...  

Materials ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 1982
Author(s):  
Weilin Liu ◽  
Jiansan Li ◽  
Xiangqi Huang ◽  
Jinye Bi

In this study, calcium carbonate (CaCO3) microparticles having pH-sensitive properties were loaded with sodium lignosulfonate (SLS), a corrosion inhibitor. Scanning electron microscope (SEM), UV–VIS spectrophotometer (UV-vis), X-ray diffraction (XRD), and attenuated total reflection-Fourier-transform infrared spectroscopy (ATR-FTIR) were applied to evaluate the properties of the synthetic microparticles. This material could lead to the release of corrosion inhibitor under different pH conditions of the aqueous media. However, the extent of release of the corrosion inhibitor in the acidic media was higher, leading to enhanced shielding effect of the Q235 steel. These microparticles can serve as anti-corrosion additive for epoxy resin-coated Q235 steel. Electrochemical experiments were used to assess the anti-corrosive ability of the epoxy coatings in simulated concrete pore (SCP) solution, confirming the superior corrosion inhibition of the epoxy coating via incorporation of 5 wt % calcium carbonate microparticles loaded with SLS (SLS/CaCO3). The physical properties of coating specimens were characterized by water absorption, contact angle, adhesion, and pencil hardness mechanical tests.


2021 ◽  
Author(s):  
Bagus Muliadi Nasution ◽  
Andrew Yonathan ◽  
Muthi Abdillah ◽  
Wang Zhen

Abstract Organic acid has been widely applied for inorganic scale treatment in oil and gas industry including well stimulation and scale inhibitor. Thanks to its low corrosivity and slower reaction rate with rock, organic acid is considered to offer better performance comparing to strong acid - Hydrochloric Acid (HCl). Yet, proper treatment requires vigorous analysis and experiment in order to meet foremost expectations. Besides, mistreatment of scale could result in formation damage including clay precipitation. Pre-treatment experiments were performed on Zelda field at South East Sumatera block, that has faced with scale problem for ages. Water sample was taken from flowing Zelda A-08 well to be analyzed for mineral's saturation level. Scale was extracted from three sources including tubing, sand bailer, and Electrical Submersible Pump (ESP) of Zelda A-08. Those scale were treated in X-Ray Powder Diffraction (XRD) for mineral composition, and solubility test that utilized two types of acid system - formic acid (HCOOH) and hydrochloric acid (HCl) for comparison. Anti-swelling test and corrosion test were performed to examine the effectiveness of clay stabilizer and corrosion inhibitor. As for carbonate analysis, both formic acid 9% and HCl 15% have comparable solubility (98.17% vs 98% for tubing's scale, 91.86% vs 82.79% for ESP's scale, and 70.30% vs 68.07% for sand bailer's scale). Yet, longer reaction is carried out by formic acid 9% (1 hour) comparing to HCl 15% (18 minutes). For silicate analysis, HF-formic acid provided the higher solubility than HF-HCl (8.34% vs 5.67% for ESP's scale and 30.48% vs 25.68% for sand bailer's scale). On anti-swelling test, by reducing swelling tendency up to 62.6%, it proves that examined clay stabilizer works perfectly against swelling potential of clay, despite of high swelling tendency of sand bailer's scale (25.8%). On corrosion test, adding on corrosion inhibitor (pyridine-based) into solution results in regular HCl 15% has corrosion rate 26.279 g/m2.h which is much higher (300%) than HF-HCl (7.977 g/m2.h) and HF-formic acid (8.229 g/m2.h). Based on pre-treatment test, formic acid 9% together with examined corrosion inhibitor and clay stabilizer, can be used as an alternative to regular HCl 15% for stimulation purpose where more areas will be covered that previously left unreachable by regular acid 15%. In addition, potentially more effective squeezed scale inhibitor using organic acid can also be achieved by performing further experiments. The method presented in this paper for pre-treatment experimental studies of organic acid can provide engineers with intensive guide to meet the best result of organic acid treatment.


Sign in / Sign up

Export Citation Format

Share Document