Corrosion behavior of the laser-brazed joint of TiNi shape memory alloy and stainless steel in artificial saliva

2006 ◽  
Vol 441 (1-2) ◽  
pp. 271-277 ◽  
Author(s):  
M.G. Li ◽  
D.Q. Sun ◽  
X.M. Qiu ◽  
S.Q. Yin
2013 ◽  
Vol 750-752 ◽  
pp. 739-742
Author(s):  
Ying Ling Wang ◽  
Qiu Zhi Gao ◽  
Gui Fang Sun ◽  
Jie Ye

The transient liquid phase diffusion bonding (TLP-DB) was employed to join TiNi shape memory alloy (SMA) and stainless steel (SS) with an interlayer metal of Ag-Cu eutectic metal foil.The corrosion behavior of the TLP-DB joint in Hanks solution at 37°C was investigated by electrochemical methods.The results show that the corrosion resistance of the joint is comparable to, but lower than that of base metals during the early anodic polarization, and the corrosion rate of the joint is between that of TiNi SMA and SS in the transpassive region at high potentials. The corrosion resistance of the specimens in Hanks' solution is associated with the surface quality, mircotructure and the intermetallics. Both TiNi SMA and SS display the characteristics of localized corrosion with a little pitting corrosion, while the joints mainly show the characteristics of pitting corrosion concentrated on the enrichment Cu phases.


2013 ◽  
Vol 2013 ◽  
pp. 1-8
Author(s):  
Chao Zhang ◽  
Xinhua Sun

The corrosion resistance of laser-welded composite arch wire (CoAW) with Cu interlayer between NiTi shape memory alloy and stainless steel wire in artificial saliva with different acidities and loads was studied. It was found that both the solution pH and the stress had a significant influence on the corrosion behaviors of the CoAW samples. Decreasing the solution pH or increasing the loading stress caused the increase of Cu release and weight loss. The corroded morphology formed on the surfaces of the CoAW was the consequence under the combined effect of corrosion and stress.


2019 ◽  
Vol 466 ◽  
pp. 165-170
Author(s):  
S. Montecinos ◽  
P. Klímek ◽  
M. Sláma ◽  
S. Suarez ◽  
S. Simison

2021 ◽  
Vol 1016 ◽  
pp. 997-1002
Author(s):  
Hikaru Nagata ◽  
Masa Ono ◽  
Yasuyuki Miyazawa ◽  
Yuji Hayashi ◽  
Yoshio Bizen

To clarify the effect of the acid solution type on corrosion resistance, the corrosion behavior of stainless steel brazed joints in HCl aqueous solution was evaluated through electrochemical measurements. Anodic polarization curves of a ferritic stainless-steel base metal, Ni-based brazing filler metals, and a brazed joint were recorded. In addition, in situ observations were conducted to observe the corrosion behavior of each structure of the brazed joint. Corrosion potentials of the brazing filler metal were lower than that of the base metal. In situ observations of the brazed joint revealed the order of corrosion in aqueous hydrochloric acid. According to the electrochemical measurements, under an actual corrosive environment, the brazing filler metal can function as an anode and selectively corrode. In addition, the anodic polarization curve of the brazed joint showed values between those of the polarization curves of the brazing filler metal and the base metal, indicating that the corrosion resistance could be electrochemically evaluated in HCl aqueous solution.


2019 ◽  
Vol 153 ◽  
pp. 348-353
Author(s):  
Zhixian Jiao ◽  
Qingzhou Wang ◽  
Fuxing Yin ◽  
Chunxiang Cui

Sign in / Sign up

Export Citation Format

Share Document