Eutectic Al–Si piston alloy surface transformed to modified hypereutectic alloy via FSP

2012 ◽  
Vol 534 ◽  
pp. 557-567 ◽  
Author(s):  
S. Tutunchilar ◽  
M.K. Besharati Givi ◽  
M. Haghpanahi ◽  
P. Asadi
2013 ◽  
Vol 58 (2) ◽  
pp. 619-624 ◽  
Author(s):  
M. Szafarska ◽  
J. Iwaszko ◽  
K. Kudła ◽  
I. Łegowik

The main aim of the study was the evaluation of magnesium alloy surface treatment effectiveness using high-energy heat sources, i.e. a Yb-YAG Disk Laser and the GTAW method. The AZ91 and AM60 commercial magnesium alloys were subject to surface layer modification. Because of the physicochemical properties of the materials studied in case of the GTAW method, it was necessary to provide the welding stand with additional equipment. A novel two-torch set with torches operating in tandem was developed within the experiment. The effectiveness of specimen remelting using a laser and the GTAW method was verified based on macro- and microscopic examinations as well as in X-ray phase analysis and hardness measurements. In addition, the remelting parameters were optimised. The proposed treatment methodology enabled the achieving of the intended result and effective modification of a magnesium alloy surface layer.


2010 ◽  
Vol 47 (9) ◽  
pp. 471-486 ◽  
Author(s):  
Z. Asghar ◽  
G. Requena ◽  
E. Boller
Keyword(s):  

2018 ◽  
Vol 69 (6) ◽  
pp. 1598-1602
Author(s):  
Alice Arina Ciocan Pendefunda ◽  
Constanta Mocanu ◽  
Doriana Agop Forna ◽  
Cristina Iordache ◽  
Elena Luca ◽  
...  

The purpose of the study is to investigate the electrochemical behavior of two dental alloys: palladium alloy (Palidor) and Ni-Cr alloy (Verasoft) in three types of artificial saliva. Determination of corrosion potential and recording of linear and cyclic polarization curves were performed with PGP201 potentiostat (VoltaLab 21- Radelkis Copenhagen. In order to study the modifications produced on the surface of the electrodes, a complex optical microscope MC 1 research type (IOR, Romania) was used, adapted to a digital camera, which was connected to a computer for the digital acquisition of images . Two metal alloys based on Ag-Pd and Ni-Cr were used for the experiments. The materials used came from different types of dental restorations removed from the oral cavity of the patients after a 5-15 years period. As corrosion environments, three artificial saliva were used: Fusayama, Afnor and Rondelli. The Pd-Ag dental alloy exhibits a very good corrosion resistance and the treatment in the Afnor saliva does not affect the surface of the alloy. Electrochemical behavior in Fusayama-Meyer�s saliva of the alloy surface results in a series of spots representing deposits of insoluble salts resulting from the oxidation process, while in the Rondelli saliva there is a series of small corrosion points on the alloy surface. The behavior of the Verasoft alloy in the Afnor and Rondelli saliva is similar; In both solutions, the potential breakthroughs are very close, but in Fusayama-Meyer�s saliva, the potential for initiation of corrosion points is very low (206 mV), a potential that can be encountered in the oral cavity. All metals and metal alloys, even the noble and semi-precious ones, are susceptible to corrosion, forming compounds with properties different from those of the metal or base alloy, which change their surface condition. Metallic dental restorations are permanently affected by the factors of the oral environment (physical-mechanical, chemical and biological), being subjected to a continuous process of degradation.


2021 ◽  
pp. 101194
Author(s):  
Masataka Ijiri ◽  
Koji Yamaguchi ◽  
Shoichi Kikuchi ◽  
Fumihiro Kato ◽  
Yui Kunieda ◽  
...  

2020 ◽  
Vol 124 (44) ◽  
pp. 24271-24278
Author(s):  
Mark Muir ◽  
David L. Molina ◽  
Arephin Islam ◽  
Mohammed K. Abdel-Rahman ◽  
Michael Trenary

Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1132 ◽  
Author(s):  
Rejane M. P. da Silva ◽  
Javier Izquierdo ◽  
Mariana X. Milagre ◽  
Abenchara M. Betancor-Abreu ◽  
Isolda Costa ◽  
...  

Amperometric and potentiometric probes were employed for the detection and characterization of reactive sites on the 2098-T351 Al-alloy (AA2098-T351) using scanning electrochemical microscopy (SECM). Firstly, the probe of concept was performed on a model Mg-Al galvanic pair system using SECM in the amperometric and potentiometric operation modes, in order to address the responsiveness of the probes for the characterization of this galvanic pair system. Next, these sensing probes were employed to characterize the 2098-T351 alloy surface immersed in a saline aqueous solution at ambient temperature. The distribution of reactive sites and the local pH changes associated with severe localized corrosion (SLC) on the alloy surface were imaged and subsequently studied. Higher hydrogen evolution, lower oxygen depletion and acidification occurred at the SLC sites developed on the 2098-T351 Al-alloy.


Sign in / Sign up

Export Citation Format

Share Document