Composite magnetic flux leakage detection method for pipelines using alternating magnetic field excitation

2017 ◽  
Vol 91 ◽  
pp. 148-155 ◽  
Author(s):  
Dehui Wu ◽  
Zhitian Liu ◽  
Xiaohong Wang ◽  
Lingxin Su
2014 ◽  
Vol 599-601 ◽  
pp. 321-325
Author(s):  
Li Qiang Sun ◽  
Hong Bo Zhu ◽  
Ming Xie ◽  
Ji Xia Li

In view of the petroleum and petrochemical characteristics of horizontal tank, ANSYS software of finite element analysis was carried out on the horizontal tank within the magnetic flux leakage testing, analyzes the influencing factors of defect magnetic flux leakage signals. Experiments verify the finite element analysis results, the experimental results show that the research of horizontal tank within the magnetic flux leakage detection effect is obvious.


2013 ◽  
Vol 718-720 ◽  
pp. 1000-1005
Author(s):  
Li Jian Yang ◽  
Sen Lin Zhang ◽  
Song Wei Gao

In order to solve the need of the oil and gas pipeline defect quantification in the real-time online defecting, magnetic flux leakage inspection method was applied to oil and gas pipeline inspection. According to the basic theory of the electromagnetic field, finite element solution of electromagnetic field and ANSYS electromagnetic field calculation theory, using the function of ANSYS 's simulation and calculation for magnetic field, three-dimensional finite element model of the oil and gas pipeline defect was built up. Through simulating, the relationship between defect signal and defect size was found, the optimal distance of the hall sensor lift-off value was verified, the best magnetization of leakage magnetic field was discussed, and various factors to influence the magnetic flux leakage signal is analyzed.


2013 ◽  
Vol 694-697 ◽  
pp. 1179-1182
Author(s):  
Yi Lai Ma ◽  
Li Lin ◽  
Kai Wen Jiang ◽  
Xu Lin Zhao

Magnetic flux leakage is one type of electromagnetic nondestructive testing (NDT) which is widely utilized in the testing the integrity of drill pipe in the field. In this paper, the 3D model of excitation unit is completely built and analyzed by ANSYS software. The magnetic field of drill pipe in the combination of full excitation device is showed by ANSYS software instead of the physic experiments which increases the efficiency tremendously and decreases the cost and achieves the anticipated desire. It is considered that this technique can provide the theoretical basis of drill pipe excitation device and the magnetic flux leakage testing of drill pipe.


2016 ◽  
Vol 853 ◽  
pp. 514-518
Author(s):  
Zhi Jun Yang ◽  
De Shu Chen ◽  
Liang Chen ◽  
Yu Zhuo Liu ◽  
Ran An ◽  
...  

Storage tank is an essential vessel in petrochemical industry, and the corrosion of tank is an important reason for the safety hazard. The corrosion of tank bottom plate is more serious than the tank wall, and it is not easy to check and repair, when damaged to a certain extent it will cause the leakage of the media, then lead to waste of energy, environmental pollution, at the same time it will cause a major accident. Magnetic flux leakage testing is widely used in the field of tank floor inspection with the advantages of fast scanning speed, accurate results and so on. In this paper, the finite element simulation and analysis of the corrosion defect leakage magnetic field is used to obtain the data, and the characteristic of the leakage magnetic field is extracted. The effect of defect depth and width and shape on the magnetic flux leakage field is studied, and the distribution curve of the magnetic flux leakage field is obtained.


2014 ◽  
Vol 620 ◽  
pp. 127-132
Author(s):  
Xiao Wen Xi ◽  
Shang Kun Ren ◽  
Li Hua Yuan

Using large finite element analysis (FEA) software ANSYS, the stress-magnetization effect on 20# steel specimens with different shape notches is simulated under the geomagnetic field and tensile load. With the stimulation, the magnetic flux leakage fields at certain positions of the surface specimen were measured. Through analysis the relationship between the magnetic flux leakage fields of certain points with tensile stress, the results showed that the magnetic field value at certain positions of specimen surface first decreases and then increases along with the increase of stress, which is called magnetization reversal phenomenon; Different gaps and different positions of the specimen show different magnetization reversal rules; By measuring the maximal variation of the magnetic field value △Hmax at certain positions of the surface specimen and by analyzing its change law, we can roughly estimate specimen stress size and distribution regularity of stress. Moreover, this article also discusses the effect of lifts-off of the probe on the law of stress magnetization.


2005 ◽  
Vol 127 (3) ◽  
pp. 274-283 ◽  
Author(s):  
J. Bruce Nestleroth ◽  
Richard J. Davis

This paper describes the design of a new magnetic flux leakage (MFL) inspection tool that performs an inline inspection to detect and characterize both metal loss and mechanical damage defects. An inspection tool that couples mechanical damage assessment as part of a routine corrosion inspection is expected to have considerably better prospects for application in the pipeline industry than a tool that complicates existing procedures. The design is based on study results that show it is feasible to detect and assess mechanical damage by applying a low magnetic field level in addition to the high magnetic field employed by most inspection tools. Nearly all commercially available MFL tools use high magnetic fields to detect and size metal loss such as corrosion. A lower field than is commonly applied for detecting metal loss is appropriate for detecting mechanical damage, such as the metallurgical changes caused by impacts from excavation equipment. The lower field is needed to counter the saturation effect of the high magnetic field, which masks and diminishes important components of the signal associated with mechanical damage. Finite element modeling was used in the design effort and the results have shown that a single magnetizer with three poles is the most effective design. Furthermore, it was found that for the three-pole system the high magnetization pole must be in the center, which was an unexpected result. The three-pole design has mechanical advantages, including a magnetic null in the backing bar, which enables installation of a pivot point for articulation of the tool through bends and restrictions. This design was prototyped and tested at Battelle’s Pipeline Simulation Facility (West Jefferson, OH). The signals were nearly identical to results acquired with a single magnetizer reconfigured between tests to attain the appropriate high and low field levels.


Sign in / Sign up

Export Citation Format

Share Document