A matched filter system for muon detection with Tilecal

Author(s):  
R.R. Ramos ◽  
J.M. Seixas ◽  
A.S. Cerqueira
1999 ◽  
Vol 35 (4) ◽  
pp. 1429-1438 ◽  
Author(s):  
S.D. Berger ◽  
B.M. Welsh

Author(s):  
J.T. Czernuszka ◽  
N.J. Long ◽  
P.B. Hirsch

In the 1970s there was considerable interest in the development of the electron channelling contrast imaging (ECCI) technique for imaging near surface defects in bulk (electron opaque) specimens. The predictions of the theories were realised experimentally by Morin et al., who used a field emission gun (FEG) operating at 40-50kV and an energy filter such that only electrons which had lost no more than a few 100V were detected. This paper presents the results of a set of preliminary experiments which show that an energy filter system is unneccessary to image and characterise the Burgers vectors of dislocations in bulk specimens. The examples in the paper indicatethe general versatility of the technique.A VG HB501 STEM with a FEG was operated at 100kV. A single tilt cartridge was used in the reflection position of the microscope. A retractable back-scattered electron detector was fitted into the secondary electron port and positioned to within a few millimetres of the specimen. The image was acquired using a Synoptics Synergy framestore and digital scan generator and subsequently processed using Semper 6. The beam divergence with the specimen in this position was 2.5 mrads with a spot size of approximately 4nm. Electron channelling patterns were used to orientate the sample.


2020 ◽  
Vol 2020 (16) ◽  
pp. 41-1-41-7
Author(s):  
Orit Skorka ◽  
Paul J. Kane

Many of the metrics developed for informational imaging are useful in automotive imaging, since many of the tasks – for example, object detection and identification – are similar. This work discusses sensor characterization parameters for the Ideal Observer SNR model, and elaborates on the noise power spectrum. It presents cross-correlation analysis results for matched-filter detection of a tribar pattern in sets of resolution target images that were captured with three image sensors over a range of illumination levels. Lastly, the work compares the crosscorrelation data to predictions made by the Ideal Observer Model and demonstrates good agreement between the two methods on relative evaluation of detection capabilities.


2019 ◽  
Vol 67 (6) ◽  
pp. 483-492
Author(s):  
Seonghyeon Baek ◽  
Iljae Lee

The effects of leakage and blockage on the acoustic performance of particle filters have been examined by using one-dimensional acoustic analysis and experimental methods. First, the transfer matrix of a filter system connected to inlet and outlet pipes with conical sections is measured using a two-load method. Then, the transfer matrix of a particle filter only is extracted from the experiments by applying inverse matrices of the conical sections. In the analytical approaches, the one-dimensional acoustic model for the leakage between the filter and the housing is developed. The predicted transmission loss shows a good agreement with the experimental results. Compared to the baseline, the leakage between the filter and housing increases transmission loss at a certain frequency and its harmonics. In addition, the transmission loss for the system with a partially blocked filter is measured. The blockage of the filter also increases the transmission loss at higher frequencies. For the simplicity of experiments to identify the leakage and blockage, the reflection coefficients at the inlet of the filter system have been measured using two different downstream conditions: open pipe and highly absorptive terminations. The experiments show that with highly absorptive terminations, it is easier to see the difference between the baseline and the defects.


2009 ◽  
Author(s):  
Richard F. Olson ◽  
William J. Braselton ◽  
Richard D. Mohlere

2003 ◽  
Author(s):  
Jeffrey Marqusee ◽  
George Robitaille ◽  
Thomas Bell

Sign in / Sign up

Export Citation Format

Share Document