Wavelet-based multiresolution analysis of cavitation-induced loading instabilities under phase effect in a waterjet pump

2021 ◽  
Vol 240 ◽  
pp. 109918
Author(s):  
Guoshou Zhao ◽  
Linlin Cao ◽  
Rui Wu ◽  
Ning Liang ◽  
Dazhuan Wu
2000 ◽  
Vol 20 (79) ◽  
pp. 356-364
Author(s):  
Taro SEKINE ◽  
Masahiro TAKEI ◽  
Michiharu OKANO ◽  
Hiroyasu NAGAE ◽  
Yoshifuru SAITO ◽  
...  

2021 ◽  
pp. 108798
Author(s):  
Renfang Huang ◽  
Yiwei Wang ◽  
Tezhuan Du ◽  
Xianwu Luo ◽  
Wei Zhang ◽  
...  
Keyword(s):  

Water ◽  
2021 ◽  
Vol 13 (1) ◽  
pp. 99
Author(s):  
Puyu Cao ◽  
Rui Zhu

Parallel compressor theory (PCT) is commonly used to estimate effects of inlet distortion on compressor performance. As well as compressor, the actual inflow to pump is also nonuniform and unfavorable for performances. Nowadays, insufficient understanding of nonuniform inflow effects on pump performance restricts its development. Therefore, this paper applies PCT to predict external characteristics and evaluate internal flow instability of waterjet pump under nonuniform inflow. According to features of nonuniform inflow, the traditional PCT is modified and makes waterjet pump sub-divided into two circumferential tubes owning same performances but with different inlet velocity (representing nonuniform inflow). Above all, numerical simulation has been conducted to validated the applicability and accuracy of PCT in head prediction of waterjet pump under nonuniform inflow, since area-weighted sum of each tube head (i.e., theoretical pump head) is highly consistent with simulated result. Moreover, based on identifications of when and which tube occurs stall, PCT evaluates four stall behaviors of waterjet pump: partial deep stall, partial stall, pre-stall and full stall. Furthermore, different stall behavior generates different interactions between head variation of each tube, resulting in a multi-segment head curve under nonuniform inflow. The modified PCT with associated physical interpretations are expected to provide a sufficient understanding of nonuniform inflow effects on pump performances.


Electronics ◽  
2021 ◽  
Vol 10 (9) ◽  
pp. 1023
Author(s):  
Arigela Satya Veerendra ◽  
Akeel A. Shah ◽  
Mohd Rusllim Mohamed ◽  
Chavali Punya Sekhar ◽  
Puiki Leung

The multilevel inverter-based drive system is greatly affected by several faults occurring on switching elements. A faulty switch in the inverter can potentially lead to more losses, extensive downtime and reduced reliability. In this paper, a novel fault identification and reconfiguration process is proposed by using discrete wavelet transform and auxiliary switching cells. Here, the discrete wavelet transform exploits a multiresolution analysis with a feature extraction methodology for fault identification and subsequently for reconfiguration. For increasing the reliability, auxiliary switching cells are integrated to replace faulty cells in a proposed reduced-switch 5-level multilevel inverter topology. The novel reconfiguration scheme compensates open circuit and short circuit faults. The complexity of the proposed system is lower relative to existing methods. This proposed technique effectively identifies and classifies faults using the multiresolution analysis. Furthermore, the measured current and voltage values during fault reconfiguration are close to those under healthy conditions. The performance is verified using the MATLAB/Simulink platform and a hardware model.


Sign in / Sign up

Export Citation Format

Share Document