scholarly journals Multiple myeloma: Detection of free monoclonal light chains by modified immunofixation electrophoresis with antisera against free light chains

2021 ◽  
pp. e00256
Author(s):  
Dorian Wilhite ◽  
Ahmed Arfa ◽  
Thomas Cotter ◽  
Natasha M. Savage ◽  
Roni J. Bollag ◽  
...  
Author(s):  
Stanley S. Levinson

AbstractSerum free light chain (FLC) analysis with ratio and urine immunofixation electrophoresis (IFE) are both available for routine use in helping to detect plasma cell dyscrasia and related diseases.Case reports showing one serum positive for serum FLC but that showed a hook effect and overestimated the amount of monoclonal FLC while urine IFE was negative for Bence Jones protein, and a second serum that showed elevated FLC κ and λ but a normal κ/λ ratio, while urine IFE was positive for Bence Jones protein.These two techniques complement one another. Neither of the techniques is truly quantitative, and both exhibit methodological defects.


2021 ◽  
Vol 156 (Supplement_1) ◽  
pp. S13-S14
Author(s):  
Rebecca Treger ◽  
Kathleen Hutchinson ◽  
Andrew Bryan ◽  
Chihiro Morishima

Abstract Protein and immunofixation (IFIX) electrophoresis are used to diagnose and monitor monoclonal gammopathies. While IFIX detects clonal production of intact immunoglobulins and free light chains (FLC), the latter can also be quantified using a serum free light chain (SFLC) assay, in which polyclonal antisera detects epitopes specific for free kappa (KFLC) or lambda light chains (LFLC). An abnormal KFLC: LFLC ratio (KLR) serves as a surrogate for clonality. While the SFLC assay is highly sensitive, normal LFLC (<2.63mg/dL) and KLR results (>0.26 & <1.65) were found in samples with distinct lambda monoclonal free light chains visualized by IFIX (X-LMFLC). To investigate this discordance, contemporaneous SFLC or KLR values were evaluated for their ability to accurately classify monoclonal FLCs identified by IFIX. We performed a retrospective analysis of serum and urine IFIX (Sebia Hydrasys) and SFLC (Freelite®, Binding Site) results from our institution between July 2010 through December 2020, using R 4.0.2 and Tidyverse packages. From among 9,594 encounters in which a single monoclonal component was initially identified by IFIX, 157 X-LMFLC and 131 X-KMFLC samples were analyzed. Elevated LFLC with normal KFLC was identified in 105/157 X-LMFLC samples (67%), while both LFLC and KFLC were elevated in 42/157 samples (27%). Concordance between X-KMFLC and KFLC was markedly higher, where 122/131 samples (93%) displayed elevated kappa FLC (>1.94mg/dL) with normal LFLC, and only 7/131 X-KMFLC samples (5%) possessed both elevated KFLC and LFLC. The use of KLR to identify pathogenic monoclonal free light chains improved lambda concordance to 85%; however, 19/157 (12%) of X-LMFLC samples still exhibited normal KLR. High concordance of 98% was again observed for X-KMFLC with abnormal KLR. When samples were segregated according to normal or impaired renal function (eGFR > or ≤60mL/min/1.73m², respectively), this disparate identification of X-LMFLC and X-KMFLC by the SFLC assay persisted, suggesting that renal dysfunction (as measured by eGFR) does not underlie this phenomenon. Lastly, we corroborated the above findings in a larger sample population by examining patients with urine Bence Jones FLC identified by IFIX who had free or intact monoclonal components in serum (N=724), grouped by lambda or kappa light chain involvement. The cause(s) of the discrepant performance by the Freelite® SFLC assay, relative to the Sebia Hydrasys IFIX assay, for identifying lambda FLC components is currently unclear. Possible contributory factors include assay reference range cutoffs, other patient disease parameters, and differences in assay-specific polyclonal antisera. Future analyses of these factors will help to further characterize SFLC assay performance and elucidate how interpretation of composite serum FLC test results can be improved to better guide patient management.


1994 ◽  
Vol 40 (10) ◽  
pp. 1869-1878 ◽  
Author(s):  
S S Levinson ◽  
D F Keren

Abstract The increased sensitivity of immunofixation electrophoresis (IFE) over prior electrophoretic methods has led to renewed interest in the study of free light chains. Here, we discuss problems associated with the identification of monoclonal free light chains (Bence Jones proteins) in urine. Besides reviewing the nature of the sample specimens and the assays themselves, we discuss the physiology, biochemistry, genetics, and immunological properties of these molecules. Direct measurement of kappa/lambda ratios may ultimately be useful, but all commercial methods available now lack sufficient sensitivity. IFE is the preferred method because of its sensitivity and ease of interpretation. There are, however, difficulties associated with the interpretation of urinary IFE patterns, because the technique does not include an intrinsic mechanism for antibody-antigen titration and because of its great sensitivity in the absence of quantification. Problems of interpretation are discussed.


2019 ◽  
Vol 12 (7) ◽  
pp. e229312
Author(s):  
Namrah Siddiq ◽  
Colin Bergstrom ◽  
Larry D Anderson ◽  
Srikanth Nagalla

Patients with multiple myeloma (MM) are at risk for acquired dysfibrinogenemia resulting in laboratory abnormalities and/or bleeding complications. We describe a 63-year-old man who presented with bleeding diathesis in the presence of a low fibrinogen activity level with a normal fibrinogen antigen level. Further studies revealed elevated levels of lambda free light chains, and he was diagnosed with MM. Despite initiating treatment with bortezomib/dexamethasone, he continued to have recurrent bleeds along with hypofibrinogenaemia, prompting a switch to carfilzomib/dexamethasone. The patient responded with improvement in bleeding symptoms, normalisation of fibrinogen activity and a decrease in serum free light chains.


2020 ◽  
Vol 8 (4) ◽  
pp. 617-624
Author(s):  
Uros Markovic ◽  
Valerio Leotta ◽  
Daniele Tibullo ◽  
Rachele Giubbolini ◽  
Alessandra Romano ◽  
...  

2020 ◽  
Vol 51 (6) ◽  
pp. 592-600 ◽  
Author(s):  
Gurmukh Singh ◽  
Roni Bollag

Abstract Objective Measurement of monoclonal immunoglobulins is a reliable estimate of the plasma cell tumor mass. About 15% of plasma cell myelomas secrete light chains only. The concentration of serum free light chains is insufficient evidence of the monoclonal light chain burden. A sensitive quantitative estimate of serum free monoclonal light chains could be useful for monitoring patients with light chain myeloma. We describe such an assay that does not require mass-spectrometry equipment or expertise. Methods Serum specimens from patients with known light chain myelomas and controls were subjected to ultrafiltration through a membrane with pore size of 50 kDa. The filtrate was concentrated and tested by immunofixation electrophoresis. The relative area under the monoclonal peak, compared to that of the total involved light chain composition, was estimated by densitometric scanning of immunofixation gels. The proportion of the area occupied by the monoclonal peak in representative densitometric scans was used to arrive at the total serum concentration of the monoclonal serum free light chains. Results Using an ultracentrifugation and concentration process, monoclonal serum free light chains were detectable, along with polyclonal light chains, in all 10 patients with active light chain myelomas. Monoclonal light chains were identified in serum specimens that did not reveal monoclonal light chains by conventional immunofixation electrophoresis. The limit of detection by this method was 1.0 mg/L of monoclonal serum free light chains. Conclusion The method described here is simple enough to be implemented in academic medical center clinical laboratories and does not require special reagents, equipment, or expertise. Even though urine examination is the preferred method for the diagnosis of light chain plasma cell myelomas, measurement of the concentration of serum free light chains provides a convenient, albeit inadequate, way to monitor the course of disease. The method described here allows effective electrophoretic differentiation of monoclonal serum free light chain from polyclonal serum free light chains and provides a quantitation of the monoclonal serum free light chains in monitoring light chain monoclonal gammopathies.


Nefrología ◽  
2018 ◽  
Vol 38 (3) ◽  
pp. 337-338
Author(s):  
Gioacchino Li Cavoli ◽  
Silvia Passanante ◽  
Onofrio Schillaci ◽  
Franca Servillo ◽  
Carmela Zagarrigo ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document