Atmospheric dispersion assessment of radioactive materials during severe accident conditions for Bushehr nuclear power plant using HYSPLIT code

2018 ◽  
Vol 108 ◽  
pp. 169-178 ◽  
Author(s):  
Ahmad Pirouzmand ◽  
Zahra Kowsar ◽  
Peyman Dehghani
2020 ◽  
Vol 7 (1) ◽  
Author(s):  
Kwame Gyamfi ◽  
Sylvester Attakorah Birikorang ◽  
Emmanuel Ampomah-Amoako ◽  
John Justice Fletcher

Abstract Atmospheric dispersion modeling and radiation dose calculation have been performed for a generic 1000 MW water-water energy reactor (VVER-1000) assuming a hypothetical loss of coolant accident (LOCA). Atmospheric dispersion code, International Radiological Assessment System (InterRAS), was employed to estimate the radiological consequences of a severe accident at a proposed nuclear power plant (NPP) site. The total effective dose equivalent (TEDE) and the ground deposition were calculated for various atmospheric stability classes, A to F, with the site-specific averaged meteorological conditions. From the analysis, 3.7×10−1 Sv was estimated as the maximum TEDE corresponding to a downwind distance of 0.1 km within the dominating atmospheric stability class (class A) of the proposed site. The intervention distance for evacuation (50 mSv) and sheltering (10 mSv) were estimated for different stability classes at different distances. The intervention area for evacuation ended at 0.5 km and that for sheltering at 1.5 km. The results from the study show that designated area for public occupancy will not be affected since the estimated doses were below the annual regulatory limits of 1 mSv.


Author(s):  
Zhifei Yang ◽  
Xiaofei Xie ◽  
Xing Chen ◽  
Shishun Zhang ◽  
Yehong Liao ◽  
...  

It is reflected in the severe accident in Fukushima Daiichi that the emergency capacity of nuclear power plant needs to be enhanced. A nuclear plant simulator that can model the severe accident is the most effective means to promote this capacity. Until now, there is not a simulator which can model the severe accident in China. In order to enhance the emergency capacity in China, we focus on developing a full scope simulator that can model the severe accident and verify it in this study. The development of severe accident simulation system mainly includes three steps. Firstly, the integral severe accident code MELCOR is transplanted to the simulation platform. Secondly, the interface program must be developed to switch calculating code from RELAP5 code to MELCOR code automatically when meeting the severe accident conditions because the RELAP5 code can only simulate the nuclear power plant normal operation state and design basis accident but the severe accident. So RELAP5 code will be stopped when severe accident conditions happen and the current nuclear power plant state parameters of it should be transported to MELCOR code, and MELCOR code will run. Finally, the CPR1000 nuclear power plant MELCOR model is developed to analyze the nuclear power plant behavior in severe accident. After the three steps, the severe accident simulation system is tested by a scenario that is initiated by the station black out with reactor cooling pump seal leakage, HHSI, LHSI and auxiliary feed water system do not work. The simulation result is verified by qualitative analysis and comparison with the results in severe accident analysis report of the same NPP. More severe accident scenarios initiated by LBLOCA, MBLOCA, SBLOCA, SBO, ATWS, SGTR, MSLB will be tested in the future. The results show that the severe accident simulation system can model the severe accident correctly; it meets the demand of emergency capacity promotion.


Author(s):  
Jung-Jae Lee ◽  
Un-Jang Lee ◽  
Goon-Cherl Park

During severe accidents in nuclear power plant (NPP), the limit of local hydrogen concentration is regulated to ensure the integrity of containment. In this study hydrogen mixing experiments were conducted to investigate the hydrogen concentration distribution in a subcompartment of NPP. The mixing compartment is a vertical rectangular type with the dimension of 1×1×1.5 m3. The helium gas was used as a simulant of hydrogen. The goals of this study are to understand local hydrogen mixing phenomena and to examine the effects of the wall condensing, of the existence of obstacle and of the containment spray operation on local hydrogen concentration in NPP. Experimental results showed that the hydrogen might be locally accumulated in the subcompartment and the local hydrogen concentration could instantaneously rise during the spray operation.


Sign in / Sign up

Export Citation Format

Share Document