scholarly journals A Study of Shading Device Configuration on the Natural Ventilation Efficiency and Energy Performance of a Double Skin Façade

2015 ◽  
Vol 118 ◽  
pp. 310-317 ◽  
Author(s):  
Jeehwan Lee ◽  
Mohammed Alshayeb ◽  
Jae D. Chang
2018 ◽  
Vol 206 ◽  
pp. 02010
Author(s):  
Nissa Aulia Ardiani ◽  
Suhendri ◽  
Mochamad Donny Koerniawan ◽  
Rachmawan Budiarto

Designed in Brutalism style by architect Andrew Renton, Tower Building has 17 floors for academic and lecturers’ office function. As the highest point in University of Nottingham, this tower has been built for almost five decades. The aim of this project is to propose the tower retrofit from current function to accommodation purpose. Improvement in terms of function and building energy performance by applying sustainable building technologies are the objectives of the retrofit. The advanced plan of building retrofit was proposed after assessing the current building performance and determined the problems. The proposed building design was based on building performance simulation result, literature, and precedent studies. Thereafter, several technologies and design ideas were applied for further investigation, to examine how is the strategies works in the building retrofit. Integrated double skin façade with BIPV, bio composite material for internal wall, double low-e glass for external wall, as well as green lung to improve natural ventilation and create public space were proposed for the building.


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3311
Author(s):  
Víctor Pérez-Andreu ◽  
Carolina Aparicio-Fernández ◽  
José-Luis Vivancos ◽  
Javier Cárcel-Carrasco

The number of buildings renovated following the introduction of European energy-efficiency policy represents a small number of buildings in Spain. So, the main Spanish building stock needs an urgent energy renovation. Using passive strategies is essential, and thermal characterization and predictive tests of the energy-efficiency improvements achieving acceptable levels of comfort for their users are urgently necessary. This study analyzes the energy performance and thermal comfort of the users in a typical Mediterranean dwelling house. A transient simulation has been used to acquire the scope of Spanish standards for its energy rehabilitation, taking into account standard comfort conditions. The work is based on thermal monitoring of the building and a numerical validated model developed in TRNSYS. Energy demands for different models have been calculated considering different passive constructive measures combined with real wind site conditions and the behavior of users related to natural ventilation. This methodology has given us the necessary information to decide the best solution in relation to energy demand and facility of implementation. The thermal comfort for different models is not directly related to energy demand and has allowed checking when and where the measures need to be done.


2021 ◽  
Vol 13 (12) ◽  
pp. 6875
Author(s):  
Irene Poza-Casado ◽  
Raquel Gil-Valverde ◽  
Alberto Meiss ◽  
Miguel Ángel Padilla-Marcos

Indoor air quality (IAQ) in educational buildings is a key element of the students’ well-being and academic performance. Window-opening behavior and air infiltration, generally used as the sole ventilation sources in existing educational buildings, often lead to unhealthy levels of indoor pollutants and energy waste. This paper evaluates the conditions of natural ventilation in classrooms in order to study how climate conditions affect energy waste. For that purpose, the impact of the air infiltration both on the IAQ and on the efficiency of the ventilation was evaluated in two university classrooms with natural ventilation in the Continental area of Spain. The research methodology was based on site sensors to analyze IAQ parameters such as CO2, Total Volatile Organic Compounds (TVOC), Particulate Matter (PM), and other climate parameters for a week during the cold season. Airtightness was then assessed within the classrooms and the close built environment by means of pressurization tests, and infiltration rates were estimated. The obtained results were used to set up a Computational Fluid Dynamics (CFD) model to evaluate the age of the local air and the ventilation efficiency value. The results revealed that ventilation cannot rely only on air infiltration, and, therefore, specific controlled ventilation strategies should be implemented to improve IAQ and to avoid excessive energy loss.


2016 ◽  
Vol 146 ◽  
pp. 251-256
Author(s):  
Hua Yang ◽  
Ying Zhou ◽  
Feng-yun Jin ◽  
Xing Zhan

2021 ◽  
Vol 69 (3) ◽  
pp. 220-228
Author(s):  
Jeehwan Lee ◽  
Jae D. Chang ◽  
Robert Coffeen

A prior study of the acoustical performance of a double-skin facade (DSF) as a noise barrier was carried out based on the percentage of the air vent open surface area, shading louver configurations, and shading louver surface materials. Earlier research findings led to experimental investigations of the acoustical performance capabilities of compact silencers to replace DSF air vents as both noise barriers and air channels because DSF air cavities, which contribute to natural ventilation performance (e.g., wind-driven or buoyancy-driven performance), are acoustically vulnerable to noise transmitted through the air vents. This experimental investigation aims to explore noise reduction (NR) through compact silencers applied to DSF air vents. Double-skin facade mock-up test cases were designed based on three test scenarios of a ventilation open surface area: (1) a 100%air vent open surface area (open mode), (2) a 0% air vent open surface area (closed mode), and (3) a compact silencer. From a data analysis of DSF mock-up test results, the overall NR values of a DSFmock-up ranged from20 to 37 dB(A) depending on the number of compact silencers and the shading louver orientation used. Configurations of compact silencers and shading louvers helped the DSF mock-up achieve additionalNR values of 5 to 10 dB(A) depending on the test case. Moreover, applying compact silencers to a naturally ventilated DSF mock-up led to significant noise reduction at low frequencies (125Hz).


2017 ◽  
Vol 1 (7) ◽  
pp. 1502-1515 ◽  
Author(s):  
Weilong Zhang ◽  
Lin Lu

Building-integrated photovoltaics (BIPV) have become a promising technology due to the urgent demand for sustainable energy supplies.


Author(s):  
Zhiqiang Zhai

Natural ventilation is one of the primary strategies for buildings in hot and mild climatic regions to reduce building cooling energy requirement. This paper uses a building energy simulation program and a computational fluid dynamics program to investigate the influence of building scales on building cooling energy consumption with and without natural ventilation. The study examines the energy performance of buildings with different L/W and H/W ratios in both Miami, FL and Los Angeles, CA. The simulation results show the varying trends of natural ventilation potential with increased building scale ratio of L/W and H/W. The comparison of the predicted energy consumptions for twenty buildings discloses the most energy-efficient building scales for rectangular-shape buildings in both hot and mild climates with and without natural ventilation. The study indicates that natural ventilation is more effective in mild climates than in hot climates, which may save cooling energy by 50% and vent fan energy by 70%. The paper analyzes the most suitable seasons for natural ventilation in Miami and Los Angeles. Further simulations indicate that extra cooling benefits associated with more natural ventilation cannot compensate additional heat gains through larger windows.


Sign in / Sign up

Export Citation Format

Share Document