Independent component analysis classification of laser induced breakdown spectroscopy spectra

2013 ◽  
Vol 86 ◽  
pp. 31-41 ◽  
Author(s):  
Olivier Forni ◽  
Sylvestre Maurice ◽  
Olivier Gasnault ◽  
Roger C. Wiens ◽  
Agnès Cousin ◽  
...  
2019 ◽  
Vol 74 (1) ◽  
pp. 42-54 ◽  
Author(s):  
Daniel Diaz ◽  
Alejandro Molina ◽  
David W. Hahn

Laser-induced breakdown spectroscopy (LIBS) and principal component analysis (PCA) were applied to the classification of LIBS spectra from gold ores prepared as pressed pellets from pulverized bulk samples. For each sample, 5000 single-shot LIBS spectra were obtained. Although the gold concentrations in the samples were as high as 7.7 µg/g, Au emission lines were not observed in most single-shot LIBS spectra, rendering the application of the usual ensemble-averaging approach for spectral processing to be infeasible. Instead, a PCA approach was utilized to analyze the collection of single-shot LIBS spectra. Two spectral ranges of 21 nm and 0.15 nm wide were considered, and LIBS variables (i.e., wavelengths) reduced to no more than three principal components. Single-shot spectra containing Au emission lines (positive spectra) were discriminated by PCA from those without the spectral feature (negative spectra) in a spectral range of less than 1 nm wide around the Au(I) 267.59 nm emission line. Assuming a discrete gold distribution at very low concentration, LIBS sampling of gold particles seemed unlikely; therefore, positive spectra were considered as data outliers. Detection of data outliers was possible using two PCA statistical parameters, i.e., sample residual and Mahalanobis distance. Results from such a classification were compared with a standard database created with positive spectra identified with a filtering algorithm that rejected spectra with an Au intensity below the smallest detectable analytical LIBS signal (i.e., below the LIBS limit of detection). The PCA approach successfully identified 100% of the data outliers when compared with the standard database. False identifications in the multivariate approach were attributed to variations in shot-to-shot intensity and the presence of interfering emission lines.


Molecules ◽  
2021 ◽  
Vol 26 (5) ◽  
pp. 1241
Author(s):  
Nikolaos Gyftokostas ◽  
Eleni Nanou ◽  
Dimitrios Stefas ◽  
Vasileios Kokkinos ◽  
Christos Bouras ◽  
...  

In the present work, the emission and the absorption spectra of numerous Greek olive oil samples and mixtures of them, obtained by two spectroscopic techniques, namely Laser-Induced Breakdown Spectroscopy (LIBS) and Absorption Spectroscopy, and aided by machine learning algorithms, were employed for the discrimination/classification of olive oils regarding their geographical origin. Both emission and absorption spectra were initially preprocessed by means of Principal Component Analysis (PCA) and were subsequently used for the construction of predictive models, employing Linear Discriminant Analysis (LDA) and Support Vector Machines (SVM). All data analysis methodologies were validated by both “k-fold” cross-validation and external validation methods. In all cases, very high classification accuracies were found, up to 100%. The present results demonstrate the advantages of machine learning implementation for improving the capabilities of these spectroscopic techniques as tools for efficient olive oil quality monitoring and control.


2021 ◽  
Author(s):  
Victor Nozais ◽  
Philippe Boutinaud ◽  
Violaine Verrecchia ◽  
Marie-Fateye Gueye ◽  
Pierre-Yves Hervé ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document