The effect of using transverse fins on a double pass flow solar air heater using wire mesh as an absorber

Solar Energy ◽  
2011 ◽  
Vol 85 (7) ◽  
pp. 1479-1487 ◽  
Author(s):  
M.F. El-khawajah ◽  
L.B.Y. Aldabbagh ◽  
F. Egelioglu
2020 ◽  
Vol 12 (9) ◽  
pp. 3619
Author(s):  
Afaq Jasim Mahmood

In this study, an experimental outdoor investigation of the thermal efficiency and outlet air temperature was conducted on an unglazed, double-pass, solar air heater with a perforated absorber plate and packing wire mesh layers as a supplemental absorbent area. This was done to observe their effects on the thermal performance of the solar air heater. The double-pass collector was constructed with a bed height of 0.05 m, and a collection area of 1.5 m2. The height of the upper channel was fixed at 0.015 m to improve the thermal efficiency, and the outlet temperature at air flow rates between 0.003 and 0.018 kg/s. The collector was mounted with a slope of 42° facing south, to maximize the intensity of solar irradiance during winter. The effects of the air flow rate, ambient temperature, inlet temperature, outlet temperature, and solar intensity were experimentally investigated. The results showed that thermal efficiency could be improved by increasing the air flow rate, where the highest thermal efficiency achieved was 86% at 0.018 kg/s. However, the temperature difference was increased to a maximum value of 38.6 °C, when the air flow rate was decreased to 0.003 kg/s. Furthermore, the results demonstrated a significant improvement in the thermal efficiency and outlet temperature; and when compared with previous research, the experimental results and the predictions for the outlet temperature using the theoretical model agreed.


2021 ◽  
Vol 39 (1A) ◽  
pp. 79-88
Author(s):  
Jalal M. Jalil ◽  
Shrooq J. Ali

This study describes an experimental investigation of the thermal efficiency of stainless steel mesh and steel wool as a porous medium in the lower channel of a double pass solar air heater. An experimental setup was planned and developed. Various types of porous media with high thermal conductivity and with different porosities have been tested. The effects of the porosity of wire mesh, the thermal conductivity of porous media, mass flow rate, and the intensity of radiation have been studied. Experimental results show that thermal efficiency with using porous media is greater than without using porous media. When used steel wool as a porous medium, the thermal efficiency reached 79.82 percent while it can be achieved 76.  The percent by using stainless mesh as porous material. The reduction in porosity increasing thermal efficiency. The thermal efficiency of multi-pass solar air collector when used steel wool as porous media is 6, 12.6 and31.7percent higher than without porous media at porosity 98.75, 97.5, and 96.25percent. While it can increase 8.1 and 28.5 percent at porosity 97.875 and 95.75 percent when using stainless steel as porous media.


2015 ◽  
Vol 138 (1) ◽  
Author(s):  
Satyender Singh ◽  
Prashant Dhiman

The present work intended to investigate thermal and thermohydraulic efficiencies of two different models of recyclic double pass packed bed solar air heaters experimentally. Model-I consists of single air pass through two glass covers as well as double air pass caused due to recycle of the air exiting from the packed bed duct formed between the absorber plate and the glass cover through another duct integrated between the absorber and back plates to inlet of the packed bed duct. On the other hand, model-II consists of only double air pass originated due to recycle operation constituted between the similar solar air heater elements as that of model-I. Twelve numbers of wire mesh screens to form 95% bed porosity were used. Both solar air heater models were tested under the range of packed bed Reynolds number from 300 to 1500 for air mass flow rate and recycle ratio of 0.01 kg/s to 0.025 kg/s and 0.3 to 1.8, respectively. Results revealed that thermal performance of model-I is found to be 15% higher than that of model-II. The optimum value of the recycle ratio for model-I and model-II are obtained as 0.9 and 1.2, respectively, at a mass flow rate of 0.025 kg/s that yields the best thermohydraulic efficiency of 77% and 67%, respectively. Moreover, optimum solution for recycle ratio and air mass flow rate during off sun shine hours are also obtained and presented in the current work.


2016 ◽  
Vol 20 (1) ◽  
pp. 175-183 ◽  
Author(s):  
Gnanadurai Sugantharaj ◽  
Kumar Vijay ◽  
Kalidasa Kulundaivel

Solar air heating is a technology in which the solar energy from the sun is captured by an absorbing medium and used to heat the air flowing through the heater. In this study, thermal performance of a double pass solar air heater has been investigated experimentally at different conditions. The experiments were conducted with different inclinations of the collector, with and without wire mesh vertically fixed at the second pass in transverse direction and with different mass flow rates. The effect of air mass flow rate, wire mesh pitch and collector inclination on temperature rise and thermal efficiency have been studied. Results show that efficiency increases with mass flow rate. For the same mass flow rate, the thermal efficiency increases with the decrease in the wire mesh pitch. The maximum daily average efficiency of air heater was 79.8% at 0.025 kg/s mass flow rate, 10 cm wire mesh gap and 9? collector inclination facing south. The highest collector efficiency was observed in solar air heaters with 10 cm wire mesh gap.


2018 ◽  
Author(s):  
D.V.N. Lakshmi ◽  
Palanisamy Muthukumar ◽  
Dr.Apurba Layek ◽  
Abhimanyu Kumar Singh ◽  
Sushoban Das

Sign in / Sign up

Export Citation Format

Share Document