A sensitive ferricyanide-mediated biochemical oxygen demand assay for analysis of wastewater treatment plant influents and treated effluents

2013 ◽  
Vol 47 (2) ◽  
pp. 841-849 ◽  
Author(s):  
Mark A. Jordan ◽  
David T. Welsh ◽  
Richard John ◽  
Kylie Catterall ◽  
Peter R. Teasdale
2020 ◽  
Vol 4 (1) ◽  
pp. 1
Author(s):  
Rudy Roxana Ayala Daza ◽  
Palmir Ponte Viera ◽  
Jhonny Valverde Flores

The objective of this research was to reduce the organic and biological load of tributaries of the Ancón Wastewater Treatment Plant using microanobubbles of air and graphene. A preliminary sample of the affluent (3L) was taken, which had an initial concentration of Biochemical Oxygen Demand (BOD5) of 410 mg/L, Chemical Oxygen Demand (COD) of 483 mg/L, Thermotolerant Coliforms of 44,000 NMP/100mL and turbidity of 63.33 NTU. The experimental part was carried out with 03 samples of 20 liters with 03 repetitions with a treatment time of 20, 40 and 60 minutes applying air nanobubbles and 6, 12 and 18 grams of graphene respectively. The results of the treated samples were: 87 mg/L representing 78.8% reduction in Biochemical Oxygen Demand (BOD5), 114 mg/L representing 76.4% reduction in Chemical Oxygen Demand (COD), 2,900 NMP/100mL that represents 93.41% reduction of Thermotolerant Coliforms and 12.4 NTU that represents 80.11% reduction of turbidity.


2018 ◽  
Vol 14 (27) ◽  
pp. 193
Author(s):  
Kamal Ait Ouhamchich ◽  
Abdelkrim Arioua ◽  
Mustapha Lbayny ◽  
Ismail Karaoui ◽  
Khalid El Habbari ◽  
...  

The wastewater purification is a complicated and costlier operation if it not well chosen. Contrariwise, it could be simple and cheaper if the treatment system respect the environmental conditions and under international standards. To purify its wastewater, Boujaâd City chose to use the natural lagooning system. To verify the ability of this system, our study focuses on assessing the performances of this system to purify Boujaad city wastewater. For this reason, this study is based on the physicochemical monitoring of raw and purified water, both spatially and temporally, to detect and determine the percentage of pollution abatement in this wastewater treatment plant. According to the results, the quality of wastewater treatment plant rejection is conforming to the national and international standards. Here, the biochemical oxygen demand (BOD), chemical oxygen demand (COD), and suspended solids (SS) parameters reached 69%, 66%, and 86% respectively. The results obtained show that the purification operation in Boujaad wastewater treatment plant was adequate.


2008 ◽  
Vol 57 (8) ◽  
pp. 1287-1293 ◽  
Author(s):  
A. Jobbágy ◽  
G. M. Tardy ◽  
Gy. Palkó ◽  
A. Benáková ◽  
O. Krhutková ◽  
...  

The purpose of the experiments was to increase the rate of activated sludge denitrification in the combined biological treatment system of the Southpest Wastewater Treatment Plant in order to gain savings in cost and energy and improve process efficiency. Initial profile measurements revealed excess denitrification capacity of the preclarified wastewater. As a consequence, flow of nitrification filter effluent recirculated to the anoxic activated sludge basins was increased from 23,000 m3 d−1 to 42,288 m3 d−1 at an average preclarified influent flow of 64,843 m3 d−1, Both simulation studies and microbiological investigations suggested that activated sludge nitrification, achieved despite the low SRT (2–3 days), was initiated by the backseeding from the nitrification filters and facilitated by the decreased oxygen demand of the influent organics used for denitrification. With the improved activated sludge denitrification, methanol demand could be decreased to about half of the initial value. With the increased efficiency of the activated sludge pre-denitrification, plant effluent COD levels decreased from 40–70 mg l−1 to < 30–45 mg l−1 due to the decreased likelihood of methanol overdosing in the denitrification filter


2012 ◽  
Vol 7 (1) ◽  
Author(s):  
S. S. Fatima ◽  
S. Jamal Khan

In this study, the performance of wastewater treatment plant located at sector I-9 Islamabad, Pakistan, was evaluated. This full scale domestic wastewater treatment plant is based on conventional activated sludge process. The parameters which were monitored regularly included total suspended solids (TSS), mixed liquor suspended solids (MLSS), mixed liquor volatile suspended solids (MLVSS), biological oxygen demand (BOD), and chemical oxygen demand (COD). It was found that the biological degradation efficiency of the plant was below the desired levels in terms of COD and BOD. Also the plant operators were not maintaining consistent sludge retention time (SRT). Abrupt discharge of MLSS through the Surplus Activated sludge (SAS) pump was the main reason for the low MLSS in the aeration tank and consequently low treatment performance. In this study the SRT was optimized based on desired MLSS concentration between 3,000–3,500 mg/L and required performance in terms of BOD, COD and TSS. This study revealed that SRT is a very important operational parameter and its knowledge and correct implementation by the plant operators should be mandatory.


2021 ◽  
Vol 221 ◽  
pp. 31-40
Author(s):  
A.S. Mubarak ◽  
Parvaneh Esmaili ◽  
Z.S. Ameen ◽  
R.A. Abdulkadir ◽  
M.S. Gaya ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document