Savings with upgraded performance through improved activated sludge denitrification in the combined activated sludge–biofilter system of the Southpest Wastewater Treatment Plant

2008 ◽  
Vol 57 (8) ◽  
pp. 1287-1293 ◽  
Author(s):  
A. Jobbágy ◽  
G. M. Tardy ◽  
Gy. Palkó ◽  
A. Benáková ◽  
O. Krhutková ◽  
...  

The purpose of the experiments was to increase the rate of activated sludge denitrification in the combined biological treatment system of the Southpest Wastewater Treatment Plant in order to gain savings in cost and energy and improve process efficiency. Initial profile measurements revealed excess denitrification capacity of the preclarified wastewater. As a consequence, flow of nitrification filter effluent recirculated to the anoxic activated sludge basins was increased from 23,000 m3 d−1 to 42,288 m3 d−1 at an average preclarified influent flow of 64,843 m3 d−1, Both simulation studies and microbiological investigations suggested that activated sludge nitrification, achieved despite the low SRT (2–3 days), was initiated by the backseeding from the nitrification filters and facilitated by the decreased oxygen demand of the influent organics used for denitrification. With the improved activated sludge denitrification, methanol demand could be decreased to about half of the initial value. With the increased efficiency of the activated sludge pre-denitrification, plant effluent COD levels decreased from 40–70 mg l−1 to < 30–45 mg l−1 due to the decreased likelihood of methanol overdosing in the denitrification filter

2012 ◽  
Vol 7 (1) ◽  
Author(s):  
S. S. Fatima ◽  
S. Jamal Khan

In this study, the performance of wastewater treatment plant located at sector I-9 Islamabad, Pakistan, was evaluated. This full scale domestic wastewater treatment plant is based on conventional activated sludge process. The parameters which were monitored regularly included total suspended solids (TSS), mixed liquor suspended solids (MLSS), mixed liquor volatile suspended solids (MLVSS), biological oxygen demand (BOD), and chemical oxygen demand (COD). It was found that the biological degradation efficiency of the plant was below the desired levels in terms of COD and BOD. Also the plant operators were not maintaining consistent sludge retention time (SRT). Abrupt discharge of MLSS through the Surplus Activated sludge (SAS) pump was the main reason for the low MLSS in the aeration tank and consequently low treatment performance. In this study the SRT was optimized based on desired MLSS concentration between 3,000–3,500 mg/L and required performance in terms of BOD, COD and TSS. This study revealed that SRT is a very important operational parameter and its knowledge and correct implementation by the plant operators should be mandatory.


2012 ◽  
Vol 7 (1) ◽  
Author(s):  
Jaroslav Pollert ◽  
Ing. Dana Pavlíčková ◽  
Ing. Vladimír Todt

The Prague's wastewater treatment plant includes mechanical and secondary biological treatment with an upgrade of the activated sludge process to partial nitrification and gentrification and gas facility. The plant's capacity (population equivalent) is 1.43 million, the hydraulic is 7.0 m3/s (during rains it is 8.2 m3/s). The main aim is to increase efficiency of sludge removal from the secondary clarifiers after necessary reconstruction. A 3D multiphase mathematical model was used to study possible efficiency improvement while 12 different scenarios (+ the present state) were simulated and compared. Simulation of the clarifiers brings new knowledge of their behaviour. The study has resulted in an optimised design of the secondary clarifiers to be used within reconstruction.


2003 ◽  
Vol 47 (12) ◽  
pp. 285-292 ◽  
Author(s):  
C.-K. Chen ◽  
S.-L. Lo

This study combines a two-phase biological treatment system of activated sludge/contact aeration process by adding biological contact filters into the rear sector of the activated sludge aeration tank of the slaughterhouse wastewater treatment plant. This system keeps the advantages of complete mixing of substrates and microorganisms and flexible operation of the activated sludge process, and increased biological phase, less sludge, process stability and good settleability of sludge of the contact aeration process. This system could avoid the defects of sludge bulking, increased sludge production and difficult operation of the activated sludge process, and system clogging and rigid operation of the contact aeration process. Because suspended microorganisms are flowing into the contact aeration system, which then degrade or suspend within the biological contact filters after being adsorbed by the fixed biological film, on which partial bio-solids will act as seeding microorganisms. Suspended microorganisms and the dropped biological film will settled in the secondary settling tank, then reflux into the activated sludge aeration tank. The partial dropped biological film will decompose in the activated sludge aeration tank to achieve the function of decreasing sludge. Large specific gravity and good settling ability of biofilm sludge will provide better effluent quality. It has been proven through a practical experiment at a slaughterhouse wastewater treatment plant in Taiwan, that the activated sludge process effluent COD value of 150-200 mg/L and SS value of 80-100 mg/L were decreased to around 40 mg/L and 22 mg/L, respectively, after changing its system to the two-phase biological treatment system of activated sludge/contact aeration process.


2016 ◽  
Vol 75 (6) ◽  
pp. 1261-1269 ◽  
Author(s):  
Fardin Abiri ◽  
Narges Fallah ◽  
Babak Bonakdarpour

In the present study the feasibility of the use of a bacterial batch sequential anaerobic–aerobic process, in which activated sludge was used in both parts of the process, for pretreatment of wastewater generated by a textile dyeing factory has been considered. Activated sludge used in the process was obtained from a municipal wastewater treatment plant and adapted to real dyeing wastewater using either an anaerobic-only or an anaerobic–aerobic process over a period of 90 days. The use of activated sludge adapted using the anaerobic–aerobic process resulted in a higher overall decolorization efficiency compared to that achieved with activated sludge adapted using the anaerobic-only cycles. Anaerobic and aerobic periods of around 34 and 22 hours respectively resulted in an effluent with chemical oxygen demand (COD) and color content which met the standards for discharge into the centralized wastewater treatment plant of the industrial estate in which the dyeing factory was situated. Neutralization of the real dyeing wastewater and addition of carbon source to it, both of which results in significant increase in the cost of the bacterial treatment process, was not found to be necessary to achieve the required discharge standards.


Renewable freshwater is a vital resource for life. Today, economic development goes hand in hand with the increase in consumption and the emergence of problems of availability or quality. The wastewater is treated in a wastewater treatment plant (Step) was late to reduce emissions and improve the protection of ecosystem quality. This study is the objective of ' exploring the cleansing station performance. The results show that the station ' Hociema by low load activated sludge allows eliminates bout 30 % to 70% for BOD5 . Nevertheless, the chemical oxygen demand is eliminated between 56% and 73% , and the COD/BOD5 ratio shows the biodegradable nature of the effluents that can be treated by a biological system, ie activated sludge treatment. from the city of Hoceima performing


1990 ◽  
Vol 22 (7-8) ◽  
pp. 131-138
Author(s):  
Ahmed Fadel

Many of Egypt's cities have existing treatment plants under operation that have been constructed before 1970. Almost all of these treatment plants now need rehabilitation and upgrading to extend their services for a longer period. One of these plants is the Beni Suef City Wastewater Treatment Plant. The Beni Suef WWTP was constructed in 1956. It has primary treatment followed by secondary treatment employing intermediate rate trickling filters. The BOD, COD, and SS concentration levels are relatively high. They are approximately 800, 1100, and 600 mg/litre, respectively. The Beni Suef city required the determination of the level of work needed for the rehabilitation and upgrading of the existing 200 l/s plant and to extend its capacity to 440 l/s at year 2000 A description of the existing units, their deficiencies and operation problems, and the required rehabilitation are presented and discussed in this paper. Major problems facing the upgrading were the lack of space for expansion and the shortage of funds. It was, therefore, necessary to study several alternative solutions and methods of treatment. The choice of alternatives was from one of the following schemes: a) changing the filter medium, its mode of operation and increasing the number of units, b) changing the trickling filter to high rate and combining it with the activated sludge process, for operation by one of several possible combinations such as: trickling filter-solids contact, roughing filter-activated sludge, and trickling filter-activated sludge process, c) dividing the flow into two parts, the first part to be treated using the existing system and the second part to be treated by activated sludge process, and d) expanding the existing system by increasing the numbers of the different process units. The selection of the alternative was based on technical, operational and economic evaluations. The different alternatives were compared on the basis of system costs, shock load handling, treatment plant operation and predicted effluent quality. The flow schemes for the alternatives are presented. The methodology of selecting the best alternative is discussed. From the study it was concluded that the first alternative is the most reliable from the point of view of costs, handling shock load, and operation.


1992 ◽  
Vol 25 (4-5) ◽  
pp. 203-209 ◽  
Author(s):  
R. Kayser ◽  
G. Stobbe ◽  
M. Werner

At Wolfsburg for a load of 100,000 p.e., the step-feed activated sludge process for nitrogen removal is successfully in operation. Due to the high denitrification potential (BOD:TKN = 5:1) the effluent total nitrogen content can be kept below 10 mg l−1 N; furthermore by some enhanced biological phosphate removal about 80% phosphorus may be removed without any chemicals.


1997 ◽  
Vol 36 (2-3) ◽  
pp. 1-8 ◽  
Author(s):  
P. Grau ◽  
B. P. Da-Rin

An unusually severe case of toxicity accompanied by activated sludge filamentous bulking was observed at the wastewater treatment plant Sao Paulo-Barueri. Treatment efficiency of the plant, operated without major problems for more than five years before, was significantly hindered for almost six months. Occurrence of toxic shocks was confirmed partly directly but mostly indirectly by inhibition of nitrification and biological phenomena related to toxicity. Several measures adopted, including the recycled activated sludge chlorination, are described in the paper.


1998 ◽  
Vol 37 (12) ◽  
pp. 141-148 ◽  
Author(s):  
B. K. Lee ◽  
S. W. Sung ◽  
H. D. Chun ◽  
J. K. Koo

The objective of this study is to develop an automatic control system for dissolved oxygen (DO) and pH of the activated sludge process in a coke wastewater treatment plant. A discrete type autotuned proportional-integral (PI) controller using an auto-regressive exogenous (ARX) model as a process model was developed to maintain the DO concentration in aerators by controlling the speed of surface aerators. Also a nonlinear pH controller using the titration curve was used to control the pH of influent wastewater. This control system was tested in a pilot scale plant. During this pilot plant experiment, there was small deviation of pH and the electric power consumption of surface aerators was reduced up to 70% with respect to the full operation when the DO set point was 2 mg/l. For real plant operation with this system, the discrete PI controller showed good tracking for set point change. The electricity saving was more than 40% of the electricity consumption when considering surface aerators. As a result of maintaining the DO constantly at the set point by the automatic control system, the fluctuation of effluent quality was decreased and overall improvement of the effluent water quality was achieved.