scholarly journals Performances Assessment of Wastewater Treatment Plant in Boujaâd City, Khouribga Province, Morocco

2018 ◽  
Vol 14 (27) ◽  
pp. 193
Author(s):  
Kamal Ait Ouhamchich ◽  
Abdelkrim Arioua ◽  
Mustapha Lbayny ◽  
Ismail Karaoui ◽  
Khalid El Habbari ◽  
...  

The wastewater purification is a complicated and costlier operation if it not well chosen. Contrariwise, it could be simple and cheaper if the treatment system respect the environmental conditions and under international standards. To purify its wastewater, Boujaâd City chose to use the natural lagooning system. To verify the ability of this system, our study focuses on assessing the performances of this system to purify Boujaad city wastewater. For this reason, this study is based on the physicochemical monitoring of raw and purified water, both spatially and temporally, to detect and determine the percentage of pollution abatement in this wastewater treatment plant. According to the results, the quality of wastewater treatment plant rejection is conforming to the national and international standards. Here, the biochemical oxygen demand (BOD), chemical oxygen demand (COD), and suspended solids (SS) parameters reached 69%, 66%, and 86% respectively. The results obtained show that the purification operation in Boujaad wastewater treatment plant was adequate.

2012 ◽  
Vol 7 (1) ◽  
Author(s):  
S. S. Fatima ◽  
S. Jamal Khan

In this study, the performance of wastewater treatment plant located at sector I-9 Islamabad, Pakistan, was evaluated. This full scale domestic wastewater treatment plant is based on conventional activated sludge process. The parameters which were monitored regularly included total suspended solids (TSS), mixed liquor suspended solids (MLSS), mixed liquor volatile suspended solids (MLVSS), biological oxygen demand (BOD), and chemical oxygen demand (COD). It was found that the biological degradation efficiency of the plant was below the desired levels in terms of COD and BOD. Also the plant operators were not maintaining consistent sludge retention time (SRT). Abrupt discharge of MLSS through the Surplus Activated sludge (SAS) pump was the main reason for the low MLSS in the aeration tank and consequently low treatment performance. In this study the SRT was optimized based on desired MLSS concentration between 3,000–3,500 mg/L and required performance in terms of BOD, COD and TSS. This study revealed that SRT is a very important operational parameter and its knowledge and correct implementation by the plant operators should be mandatory.


Author(s):  
Tomáš Vítěz ◽  
Jana Ševčíková ◽  
Petra Oppeltová

This paper is focused on primary, secondary, and total efficiency evaluation of the wastewater treatment process for chosen small wastewater treatment plant (WWTP) located near the Moravian Karst. Eight wastewater samples were taken during one year in three sampling profiles of WWTP: biochemical oxygen demand (BOD), chemical oxygen demand (COD), suspended solids (SS), pH, ammonia nitrogen (N-NH4), nitrite nitrogen (N-NO2), nitrate nitrogen (N-NO3), inorganic nitrogen (Ninorg), total phosphorus (Ptotal). Treatment efficiency by reduction was calculated for all laboratory analyzed indicators and average values were determined for the whole period. Calculated treatment efficiency of indicators BOD, COD and suspended solids was compared with the permissible minimum treatment efficiency of discharged waste water by Government Regulation No. 61/2003 Coll., for the WWTP from 500 to 2 000 PE. Permissible minimum treatment efficiency is not legislatively determined for the primary and secondary level. The results of the work will be used especially to compare results with other similar works.Analyzed values ​​of parameters BOD, COD, suspended solids, N-NH4 at the outflow from wastewater treatment plant were compared with the permissible maximum values at the outflow of the WWTP which the municipality has an obligation to respect according to the decision issued by the District Environment Authority.


2005 ◽  
Vol 51 (11) ◽  
pp. 159-166
Author(s):  
E. Ubay-Cokgor ◽  
C.W. Randall ◽  
D. Orhon

In this paper, the performance of the Tyson Foods wastewater treatment plant with an average flow rate of 6500 m3/d was evaluated before and after upgrading of the treatment system for nitrogen removal. This study was also covered with an additional recommendation of BIOWINTM BNR program simulation after the modification period to achieve an additional nutrient removal. The results clearly show that the upgrading was very successful for improved nitrogen removal, with a 57% decrease on the total nitrogen discharge. There also were slight reductions in the discharged loads of biological oxygen demand, total suspended solids, ammonium and total phosphorus with denitrification, even though the effluent flow was higher during operation of the nitrogen removal configuration.


2021 ◽  
Vol 6 (2) ◽  
pp. 361-370
Author(s):  
Asma Khelassi- Sefaoui ◽  
Abderrahmane Khechekhouche ◽  
Manel Zaoui-Djelloul Daouadji ◽  
Hamza Idrici

Wastewater treatment is a process used in several countries, particularly in Algeria. A study on Earth for one month was carried out at the sewage plant of the Sebdou textile complex, Tlemcen, north-west of Algeria. Regular samples gave average values at the outlet such that the water temperature is 22 ° C, the ph 7.43, the biochemical oxygen demand BOD5 is 36.5 mg / l, the chemical oxygen demand COD vary between 100 and 200 mg / l at the exit of the WWTP mg / l and finally suspended solids SS is of the order of 36.2 mg / l. All these values conform with the standards and therefore the treatment plant operates within Algerian standards.


Processes ◽  
2022 ◽  
Vol 10 (1) ◽  
pp. 85
Author(s):  
Barbara Wodecka ◽  
Jakub Drewnowski ◽  
Anita Białek ◽  
Ewa Łazuka ◽  
Joanna Szulżyk-Cieplak

One of the important factors determining the biochemical processes in bioreactors is the quality of the wastewater inflow to the wastewater treatment plant (WWTP). Information on the quality of wastewater, sufficiently in advance, makes it possible to properly select bioreactor settings to obtain optimal process conditions. This paper presents the use of classification models to predict the variability of wastewater quality at the inflow to wastewater treatment plants, the values of which depend only on the amount of inflowing wastewater. The methodology of an expert system to predict selected indicators of wastewater quality at the inflow to the treatment plant (biochemical oxygen demand, chemical oxygen demand, total suspended solids, and ammonium nitrogen) on the example of a selected WWTP—Sitkówka Nowiny, was presented. In the considered system concept, a division of the values of measured wastewater quality indices into lower (reduced values of indicators in relation to average), average (typical and most common values), and upper (increased values) were adopted. On the basis of the calculations performed, it was found that the values of the selected wastewater quality indicators can be identified with sufficient accuracy by means of the determined statistical models based on the support vector machines and boosted trees methods.


Sign in / Sign up

Export Citation Format

Share Document