Variable-parameter feedforward control for centrifuge shaking table based on nonlinear frequency characteristic model

2021 ◽  
Vol 161 ◽  
pp. 108011
Author(s):  
Junting Lu ◽  
Haibo Xie ◽  
Liang Hu ◽  
Huayong Yang ◽  
Yunmin Chen
2011 ◽  
Vol 199-200 ◽  
pp. 1397-1404
Author(s):  
Zhen Bao Li ◽  
Zhen Yun Tang ◽  
Jin Bao Ji ◽  
Xiao Liang Li ◽  
Da Xing Zhou ◽  
...  

This paper presents the defects existing in shaking table control including the overshoot of displacement under low-middle frequency input using three variable parameter controls, the narrow bandwidth resulting from the performance of servo-valve and low accuracy of seismic wave reproduction because of specimen and table interaction. The effects of these factors on the stability and control accuracy of shaking table are discussed, and then the reasons of these problems existing are analyzed. The aim of this paper is to improve the stability and control accuracy of shaking table, thus, some corresponding strategies for compensation control are proposed. And a series of shaking table tests with one-story frame and two-story frame for verifying the validity of compensation control algorithm are performed.


2019 ◽  
Vol 28 (2S) ◽  
pp. 915-924 ◽  
Author(s):  
Kristie A. Spencer ◽  
Mallory Dawson

Purpose This preliminary study examined whether speech profiles exist for adults with hereditary ataxia based on 2 competing frameworks: a pattern of instability/inflexibility or a pattern of differential subsystem involvement. Method Four dysarthria experts rated the speech samples of 8 adults with dysarthria from hereditary ataxia using visual analog scales and presence/severity rating scales of speech characteristics. Speaking tasks included diadochokinetics, sustained phonation, and a monologue. Results Speech profiles aligned with the instability/inflexibility framework, with the pattern of instability being the most common. Speech profiles did not emerge for the majority of speakers using the differential subsystem framework. Conclusions The findings extend previous research on pure ataxic dysarthria and suggest a possible framework for understanding the speech heterogeneity associated with the ataxias. The predominance of the instability profile is consistent with the notion of impaired feedforward control in speakers with cerebellar disruption.


2019 ◽  
Vol 62 (5) ◽  
pp. 1486-1505
Author(s):  
Joshua M. Alexander

PurposeFrequency lowering in hearing aids can cause listeners to perceive [s] as [ʃ]. The S-SH Confusion Test, which consists of 66 minimal word pairs spoken by 6 female talkers, was designed to help clinicians and researchers document these negative side effects. This study's purpose was to use this new test to evaluate the hypothesis that these confusions will increase to the extent that low frequencies are altered.MethodTwenty-one listeners with normal hearing were each tested on 7 conditions. Three were control conditions that were low-pass filtered at 3.3, 5.0, and 9.1 kHz. Four conditions were processed with nonlinear frequency compression (NFC): 2 had a 3.3-kHz maximum audible output frequency (MAOF), with a start frequency (SF) of 1.6 or 2.2 kHz; 2 had a 5.0-kHz MAOF, with an SF of 1.6 or 4.0 kHz. Listeners' responses were analyzed using concepts from signal detection theory. Response times were also collected as a measure of cognitive processing.ResultsOverall, [s] for [ʃ] confusions were minimal. As predicted, [ʃ] for [s] confusions increased for NFC conditions with a lower versus higher MAOF and with a lower versus higher SF. Response times for trials with correct [s] responses were shortest for the 9.1-kHz control and increased for the 5.0- and 3.3-kHz controls. NFC response times were also significantly longer as MAOF and SF decreased. The NFC condition with the highest MAOF and SF had statistically shorter response times than its control condition, indicating that, under some circumstances, NFC may ease cognitive processing.ConclusionsLarge differences in the S-SH Confusion Test across frequency-lowering conditions show that it can be used to document a major negative side effect associated with frequency lowering. Smaller but significant differences in response times for correct [s] trials indicate that NFC can help or hinder cognitive processing, depending on its settings.


TAPPI Journal ◽  
2018 ◽  
Vol 17 (05) ◽  
pp. 261-269
Author(s):  
Wei Ren ◽  
Brennan Dubord ◽  
Jason Johnson ◽  
Bruce Allison

Tight control of raw green liquor total titratable alkali (TTA) may be considered an important first step towards improving the overall economic performance of the causticizing process. Dissolving tank control is made difficult by the fact that the unknown smelt flow is highly variable and subject to runoff. High TTA variability negatively impacts operational costs through increased scaling in the dissolver and transfer lines, increased deadload in the liquor cycle, under- and over-liming, increased energy consumption, and increased maintenance. Current practice is to use feedback control to regulate the TTA to a target value through manipulation of weak wash flow while simultaneously keeping dissolver density within acceptable limits. Unfortunately, the amount of variability reduction that can be achieved by feedback control alone is fundamentally limited by the process dynamics. One way to improve upon the situation would be to measure the smelt flow and use it as a feedforward control variable. Direct measurement of smelt flow is not yet possible. The use of an indirect measurement, the dissolver vent stack temperature, is investigated in this paper as a surrogate feedforward variable for dissolving tank TTA control. Mill trials indicate that significant variability reduction in the raw green liquor TTA is possible and that the control improvements carry through to the downstream processes.


Sign in / Sign up

Export Citation Format

Share Document