P645 An empiric model for three-dimensional reconstruction of coronary vessels from X-ray angiography

2003 ◽  
Vol 24 (5) ◽  
pp. 114
Author(s):  
O RODRIGUEZLEOR
2019 ◽  
Author(s):  
Naoki Sunaguchi ◽  
Daisuke Shimao ◽  
Shu Ichihara ◽  
Kensaku Mori ◽  
Tetsuya Yuasa ◽  
...  

2016 ◽  
Vol 49 (2) ◽  
pp. 544-555 ◽  
Author(s):  
Nicola Viganò ◽  
Laura Nervo ◽  
Lorenzo Valzania ◽  
Gaurav Singh ◽  
Michael Preuss ◽  
...  

Three-dimensional X-ray orientation microscopy based on X-ray full-field imaging techniques such as diffraction contrast tomography is a challenging task when it comes to materials displaying non-negligible intragranular orientation spread and/or intricate grain microstructures as a result of plastic deformation and deformation twinning. As shown in this article, the optimization of the experimental conditions and a number of modifications of the data analysis routines enable detection and three-dimensional reconstruction of twin lamellae down to micrometre thickness, as well as more accurate three-dimensional reconstruction of grains displaying intragranular orientation spreads of up to a few degrees. The reconstruction of spatially resolved orientation maps becomes possible through the use of a recently introduced six-dimensional reconstruction framework, which has been further extended in order to enable simultaneous reconstruction of parent and twin orientations and to account for the finite impulse response of the X-ray imaging detector. The simultaneous reconstruction of disjoint orientation domains requires appropriate scaling of the scattering intensities based on structure and Lorentz factors and yields three-dimensional reconstructions with comparable density values for all the grains. This in turn enables the use of a global intensity-guided assembly procedure and avoids problems related to the single-grain thresholding procedure used previously. Last but not least, carrying out a systematic search over the list of known twin variants (forward modelling) for each of the indexed parent grains, it is possible to identify additional twins which have been left undetected at the previous stage of grain indexing based on diffraction spot peak positions. The enhanced procedure has been tested on a 1% deformed specimen made from a Ti–4% Al alloy and the result has been cross-validated against a two-dimensional electron backscatter diffraction orientation map acquired on one of the lateral sample surfaces.


2021 ◽  
Vol 2021 ◽  
pp. 1-4
Author(s):  
Yuanyuan Shi ◽  
Si Chen ◽  
Xue Chen ◽  
Pan Xue

Aim. To study the diagnostic effect of hip fracture in the elderly. In this paper, a total of 100 elderly patients with hip fracture from January 2020 to May 2021 were selected for X-ray and CT examination after admission. The operation was taken as the final criteria for determining hip fracture type, and the diagnosis of hip fracture by CT three-dimensional reconstruction was analyzed and studied. The results showed that the diagnostic rate of CT 3D reconstruction for various types of hip fracture in the elderly was higher than that of CT plain scan and X-ray ( P < 0.05 ). For the diagnosis of intra-articular small bone fragments, the rate of missed diagnosis was 2% (2/100) with CT 3D reconstruction, 10% (10/100) with conventional CT scan, and 20% (20/100) with X-ray. The rate of misdiagnosis was 5.0% (5/100) with CT 3D reconstruction. Routine CT scan was 15% (15/100), X-ray was 30% (30/100), and CT 3D reconstruction was significantly lower than other examinations ( P < 0.05 ). Conclusion. CT 3D reconstruction has high accuracy in the diagnosis of various types of hip fractures in the elderly.


Sign in / Sign up

Export Citation Format

Share Document