Development of a high-performance liquid chromatographic–electrospray mass spectrometric assay for the specific and sensitive quantification of the novel immunosuppressive macrolide 40-O-(2-hydroxyethyl)rapamycin

Author(s):  
Ignacio Segarra ◽  
Timothy R Brazelton ◽  
Natalya Guterman ◽  
Bernard Hausen ◽  
Wolfgang Jacobsen ◽  
...  
INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (07) ◽  
pp. 32-37
Author(s):  
Vijaya Lakshmi Marella ◽  
Chaitanya S. N ◽  

A selective and sensitive reverse phase High Performance Liquid Chromatographic method has been developed and validated for the estimation of lornoxicam in bulk, pharmaceutical dosage forms and in dissolution samples. The analysis was performed isocratically on an Inertsil column (250* 4.6 mm, 5 µm) using a mass spectrometric compatible mobile phase of 10 mM ammonium acetate: acetonitrile (50:50 V/V) at a flow rate of 1 mL/min.The detection wavelength was 290 nm. The retention time was found to be 4.573 min for lornoxicam. The linearity of the method has been satisfied with Beer Lambert’s law in the concentration range of 5-25 µg/mL with a correlation coefficient of 0.9988. The mean recoveries assessed for lornoxicam were in the range of 100.39-101.86 %, indicating good accuracy of the method. The limit of detection and limit of quantification were found to be 0.03 and 0.11 µg/mL, respectively. The developed method has been statistically validated in accordance with ICH guidelines and found to be mass spectrometric compatible, simple, precise, and accurate with the prescribed values. Thus, the proposed method was successfully applied for the estimation of lornoxicam in routine quality control analysis of bulk, formulations and in dissolution samples.


1982 ◽  
Vol 65 (6) ◽  
pp. 1388-1394 ◽  
Author(s):  
Roger C Snyder ◽  
William C Brumley ◽  
Charles V Breder ◽  
Thomas Fazio

Abstract The confirmation of 2,4- and 2,6-toluenediamine (TDA) in aqueous extracts from boil-in-bags and retortable pouches is described. The extracts were initially analyzed by a high performance liquid chromatographic procedure and any apparent 2,4- and/or 2,6-TDA were quantitated. The liquid chromatographic effluent corresponding to any apparent 2,4- or 2,6-TDA was collected. TDA was then partitioned into ethyl acetate and reacted with trifluoroacetic anhydride (TFAA). The TDA-TFAA derivative formed was confirmed by gas-liquid chromatography (GLC) using a 1.2 m × 0.32 cm nickel column packed with 6% OV-17 on Superpak-20M. Results obtained from analyzing extracts of several retortable pouches and boil-in-bags showed levels of TDA migration ranging from <0.1 to 2.2 ppb (μg/L). Additional confirmation of the TDA-TFAA derivative from retortable pouches by multiple ion detection GC/mass spectrometry is also described.


Sign in / Sign up

Export Citation Format

Share Document