Clinical impact of MRI vs computed tomography in the diagnostic work-up of colon cancer patients

2017 ◽  
Vol 72 ◽  
pp. S54 ◽  
Author(s):  
M. Lahaye ◽  
D. Lambregts ◽  
E. Nerad ◽  
F. Bakers ◽  
G. Beets ◽  
...  
2014 ◽  
Vol 87 (3) ◽  
pp. 138-142 ◽  
Author(s):  
Jimmy Tiong ◽  
Andrew Gray ◽  
Christopher Jackson ◽  
Mark Thompson-Fawcett ◽  
Michael Schultz

1996 ◽  
Vol 36 (6) ◽  
pp. 347-348 ◽  
Author(s):  
Philippe Demaerel ◽  
Ignace Boelaert ◽  
Guy Wilms ◽  
Albert L. Baert

2018 ◽  
Vol 22 (7) ◽  
pp. 1-114 ◽  
Author(s):  
Paula Ghaneh ◽  
Robert Hanson ◽  
Andrew Titman ◽  
Gill Lancaster ◽  
Catrin Plumpton ◽  
...  

Background Pancreatic cancer diagnosis and staging can be difficult in 10–20% of patients. Positron emission tomography (PET)/computed tomography (CT) adds precise anatomical localisation to functional data. The use of PET/CT may add further value to the diagnosis and staging of pancreatic cancer. Objective To determine the incremental diagnostic accuracy and impact of PET/CT in addition to standard diagnostic work-up in patients with suspected pancreatic cancer. Design A multicentre prospective diagnostic accuracy and clinical value study of PET/CT in suspected pancreatic malignancy. Participants Patients with suspected pancreatic malignancy. Interventions All patients to undergo PET/CT following standard diagnostic work-up. Main outcome measures The primary outcome was the incremental diagnostic value of PET/CT in addition to standard diagnostic work-up with multidetector computed tomography (MDCT). Secondary outcomes were (1) changes in patients’ diagnosis, staging and management as a result of PET/CT; (2) changes in the costs and effectiveness of patient management as a result of PET/CT; (3) the incremental diagnostic value of PET/CT in chronic pancreatitis; (4) the identification of groups of patients who would benefit most from PET/CT; and (5) the incremental diagnostic value of PET/CT in other pancreatic tumours. Results Between 2011 and 2013, 589 patients with suspected pancreatic cancer underwent MDCT and PET/CT, with 550 patients having complete data and in-range PET/CT. Sensitivity and specificity for the diagnosis of pancreatic cancer were 88.5% and 70.6%, respectively, for MDCT and 92.7% and 75.8%, respectively, for PET/CT. The maximum standardised uptake value (SUVmax.) for a pancreatic cancer diagnosis was 7.5. PET/CT demonstrated a significant improvement in relative sensitivity (p = 0.01) and specificity (p = 0.023) compared with MDCT. Incremental likelihood ratios demonstrated that PET/CT significantly improved diagnostic accuracy in all scenarios (p < 0.0002). PET/CT correctly changed the staging of pancreatic cancer in 56 patients (p = 0.001). PET/CT influenced management in 250 (45%) patients. PET/CT stopped resection in 58 (20%) patients who were due to have surgery. The benefit of PET/CT was limited in patients with chronic pancreatitis or other pancreatic tumours. PET/CT was associated with a gain in quality-adjusted life-years of 0.0157 (95% confidence interval –0.0101 to 0.0430). In the base-case model PET/CT was seen to dominate MDCT alone and is thus highly likely to be cost-effective for the UK NHS. PET/CT was seen to be most cost-effective for the subgroup of patients with suspected pancreatic cancer who were thought to be resectable. Conclusion PET/CT provided a significant incremental diagnostic benefit in the diagnosis of pancreatic cancer and significantly influenced the staging and management of patients. PET/CT had limited utility in chronic pancreatitis and other pancreatic tumours. PET/CT is likely to be cost-effective at current reimbursement rates for PET/CT to the UK NHS. This was not a randomised controlled trial and therefore we do not have any information from patients who would have undergone MDCT only for comparison. In addition, there were issues in estimating costs for PET/CT. Future work should evaluate the role of PET/CT in intraductal papillary mucinous neoplasm and prognosis and response to therapy in patients with pancreatic cancer. Study registration Current Controlled Trials ISRCTN73852054 and UKCRN 8166. Funding The National Institute for Health Research Health Technology Assessment programme.


2018 ◽  
Vol 25 (7) ◽  
pp. 1986-1991 ◽  
Author(s):  
Joris van den Broek ◽  
Remy Geenen ◽  
Luc Heijnen ◽  
Carolien Kobus ◽  
Hermien Schreurs

PEDIATRICS ◽  
1982 ◽  
Vol 69 (4) ◽  
pp. 472-475
Author(s):  
Karen S. Rheuban ◽  
Nancy Ayres ◽  
J. Gordon Still ◽  
Bennett Alford

The pulmonary artery sling is a vascular anomaly that produces severe respiratory disease in infancy. The differential diagnosis is lengthy, and the diagnostic work-up frequently includes such invasive maneuvers as bronchography, bronchoscopy, and cardiac catheterization. In this paper the use of a new noninvasive diagnostic tool, computed tomography, to aid in the diagnosis of this form of vascular ring, is discussed and a review of salient features of this cardiovascular malformation is presented.


Author(s):  
Carlos Miguel Chiesa-Estomba ◽  
Maria Soriano-Reixach ◽  
Ekhiñe Larruscain-Sarasola ◽  
Jon Alexander Sistiaga-Suarez ◽  
Jose Angel González-García ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document