Determination of Serum Fibrosis Indexes in Patients with Capsular Contracture after Augmentation with Smooth Silicone Gel Implants

2008 ◽  
Vol 2008 ◽  
pp. 195-196
Author(s):  
R.L. Ruberg
2006 ◽  
Vol 118 (1) ◽  
pp. 224-229 ◽  
Author(s):  
Lukas Prantl ◽  
Peter Angele ◽  
Stefan Schreml ◽  
Dietmar Ulrich ◽  
Nina P??ppl ◽  
...  

2019 ◽  
Vol 6 (2) ◽  
pp. 43 ◽  
Author(s):  
Harold J. Brandon ◽  
Larry S. Nichter ◽  
Dwight D. Back

The IDEAL IMPLANT® Structured Breast Implant is a dual lumen saline-filled implant with capsular contracture and deflation/rupture rates much lower than single-lumen silicone gel-filled implants. To better understand the implant’s mechanical properties and to provide a potential explanation for these eight-year clinical results, a novel approach to compressive load testing was employed. Multi-dimensional strains and tangent moduli, metrics describing the shape stability of the total implant, were derived from the experimental load and platen spacing data. The IDEAL IMPLANT was found to have projection, diametric, and areal strains that were generally less than silicone gel implants, and tangent moduli that were generally greater than silicone gel implants. Despite having a relatively inviscid saline fill, the IDEAL IMPLANT was found to be more shape stable compared to gel implants, which implies potentially less interaction with the capsule wall when the implant is subjected to compressive loads. Under compressive loads, the shape stability of a higher cross-link density, cohesive gel implant was unexpectedly found to be similar to or the same as a gel implant. In localized diametric compression testing, the IDEAL IMPLANT was found to have a palpability similar to a gel implant, but softer than a cohesive gel implant.


2002 ◽  
Vol 10 (5) ◽  
pp. 223-236 ◽  
Author(s):  
Walter Peters

The present review traces the evolution of breast implants over the past 50 years. During the early years (from 1951 to 1962), a number of different sponges were used for breast augmentation. The first of these was Ivalon, a polyvinyl alcohol sponge. Other sponges were introduced subsequently, including Etheron (a poly-ether sponge popularized by Dr Paule Regnault in Montreal) and Polystan (fabric tapes that were wound into a ball). Subsequently, polyethylene strips enclosed in a fabric or polyethylene casing were also used for breast augmentation. All of these materials had similar outcomes. Although the initial results were encouraging, within one year of augmentation, breasts became very firm and lost over 25% of their volume. This was due to capsular contracture, a process that would lead to the collapse of the sponge and would continue to plague plastic surgeons and their patients for the next 50 years. In 1963, Cronin and Gerow introduced the silicone gel ‘natural feel’ implant, which revolutionized breast augmentation surgery. Approximately 10 companies have manufactured many types of silicone gel breast implants over the years. They obtained their raw materials for gels and shells from a similar number of other companies that entered and left the market at intervals. Many of the suppliers and manufactures changed their names and ownership over the years, and most of the companies no longer exist. No formal process of United States Food and Drug Administration premarket testing was in effect until 1988. There have been three generations of gel implants and a number of other lesser variations. First-generation implants (1963 to 1972) had a thick gel and a thick wall. They have generally remained intact over the years. Second-generation implants (1973 to the mid-1980s) had a thin gel and a thin wall. They have tended to disrupt over time. Third-generation implants (mid-1980s to 1992) had a thick wall and a thick gel. Except for those made by Surgitek, these implants remain intact. The breast implant business was competitive and companies introduced changes such as softer gels; barrier low-bleed shells; greater or lesser shell thickness; surface texturing; different sizes, contours and shapes; and multiple lumens in search of better aesthetics. Ultimately, more than 240 styles and 8300 models of silicone gel breast implants were manufactured in the United States alone. Inflatable breast implants were introduced in Toulons, France in 1965 (the Simaplast implant). There have been three main eras of inflatable implants: seamed, high-temperature vulcanized and room temperature vulcanized implants. In 1973, spontaneous deflation rates of 76% to 88% over three years were reported for many types of inflatable implants. Because of this, most plastic surgeons abandoned their use. From 1963 until the moratorium on gel implants (January 6, 1992), about 95% of all breast implants inserted were silicone gel filled. Only 5% were saline filled. Since the moratorium, this ratio has been reversed and 95% of all implants have been saline-filled, with only 5% being gel filled. Polyurethane-coated (PU) silicone gel implants were introduced in 1968. Over the next 20 years, they were shown to reduce the prevalence of capsular contracture to 2% to 3%. Other forms of surface texturing (Biocell, Siltex, multistructured implant) also appear to reduce capsular contracture with gel implants, but the reduction has been much less dramatic than that seen with PU implants. Contoured (anatomical) shaping appears to have advantages in some patients with gel implants. No such advantage has been seen for texturing or shaping with saline-filled implants. The story of gel implants has culminated in the largest class action lawsuit in medical history, with US$4.2 billion being awarded to women with silicone gel implants. During the past decade, there has been a tremendous amount of research on the reaction of a woman's body to gel implants. A plethora of studies have demonstrated that silicone gel implants are not associated with the development of any medical diseases. Silicone gel-filled implants have therefore been approved for use under Health Canada's Special Access Program. Silicone gel-filled implants may now be used in certain patients in whom they would provide advantages over saline implants. Silicone gel implants have not been approved for unrestricted general use. The evolution of breast implants occupies the past half century. It has been a stormy course, with many exciting advances and many bitter disappointments. The universe of breast implants is large and the variation among the implants is substantial. The purpose of the present review is to trace the evolution of breast implants over the past 50 years.


2012 ◽  
Vol 130 (4) ◽  
pp. 793-800 ◽  
Author(s):  
Hunter R. Moyer ◽  
Bahair H. Ghazi ◽  
Albert Losken

2019 ◽  
Vol 1 (2) ◽  
Author(s):  
Franck Duteille ◽  
Pierre Perrot ◽  
Marie-Hélène Bacheley ◽  
Erin Bell ◽  
Sharon Stewart

Abstract Background Although silicone breast implants have been available for over 60 years, their safety and efficacy continue to be assessed via long-term clinical and vigilance studies. Complications often associated with breast implant surgery include but are not limited to capsular contracture and rupture. Objective The authors investigate and evaluate the safety and performance of Eurosilicone’s (Eurosilicone S.A.S, Apt Cedex, France) Cristalline Paragel breast implants at least 10 years postimplantation. Methods Nine hundred and ninety-five of Eurosilicone’s textured mammary implants were implanted in 526 women undergoing primary (423 patients) and revision surgery (103 patients) at 17 centers throughout France. Complications were recorded at 3 months and annually thereafter for 10 years. Descriptive statistics were used and the Kaplan-Meier method was utilized to analyze key complications. Results Seventy-four women (98 implants) experienced capsular contracture across all cohorts. The Kaplan-Meier 10-year cumulative risk of capsular contracture (Baker Grade III/IV) per implant was 11.5% in the primary augmentation cohort and 25.2% in the primary reconstruction cohort. Sixteen implant ruptures were observed by surgeon examination giving a Kaplan-Meier risk of 3.8% per patient and 3.5% per implant. Surgical re-intervention (explantation/exchange) was reported 80 times resulting in a Kaplan-Meier cumulative risk of 13.3% and 31.6% for primary augmentation and primary reconstruction, respectively, per patient. Local complication rates including infection and seroma were low with risk rates of 0.6% and 0.2% by subject. Conclusions This multicenter clinical study demonstrates the long-term safety and efficacy profile through 10 years for Eurosilicone round and anatomical silicone gel breast implants. Level of Evidence: 3


2019 ◽  
Vol 40 (5) ◽  
pp. 499-512 ◽  
Author(s):  
Frank Lista ◽  
Ryan E Austin ◽  
Maryam Saheb-Al-Zamani ◽  
Jamil Ahmad

Abstract Background Previous studies have reported decreased rates of capsular contracture associated with the use of textured surface breast implants placed in the subglandular plane during breast augmentation. However, since the publication of these studies, our understanding of the pathophysiology of capsular contracture, as well as the surgical techniques utilized to minimize bacterial contamination of the implant, have advanced considerably. Objectives The purpose of this study was to re-evaluate the relation between implant surface texturization and capsular contracture rates for breast implants placed in the subglandular plane during primary breast augmentation. Methods Retrospective chart review was performed of all primary subglandular breast augmentation procedures involving the use of either smooth or textured round silicone gel implants, with or without simultaneous mastopexy. The primary outcome measures included clinically significant capsular contracture (Baker grade III/IV) and revision surgery for capsular contracture. Results Between 2010 and 2017, 526 patients underwent primary subglandular breast augmentation with either smooth (n = 212) or textured (n = 314) round silicone gel implants; 248 patients underwent breast augmentation, whereas 278 underwent breast augmentation-mastopexy. Average follow-up was 756 days in the textured group and 461 days in the smooth group. Five cases of capsular contracture were observed in the textured group, and 7 cases of capsular contracture were observed in the smooth group (P = 0.20). Conclusions Smooth surface implants placed in the subglandular plane were not at a significantly increased risk of capsular contracture compared with textured surface implants. We suggest that adherence to a surgical technique focused on minimizing bacterial contamination of the implant is of greater clinical significance than implant surface characteristics when discussing capsular contracture. Level of Evidence: 4


1995 ◽  
Vol 76 (3_suppl) ◽  
pp. 1323-1330 ◽  
Author(s):  
Rebecca Cogwell Anderson ◽  
David L. Larson

Media coverage tends to focus on sensational aspects. Especially prominent are controversial items related to public health and well-being. This research examined the response by breast-reconstruction and breast-augmentation patients to extensive media coverage regarding silicone gel-filled implants. Results of our survey suggested that media coverage influenced these women. Common concerns expressed by respondents included autoimmune disease, capsular contracture, leakage, increased risk of cancer, and anxiety. All respondents used consultation with their physicians as a primary means of coping with anxiety. Anxiety over media coverage Jed to some hesitancy concerning use of implants by surveyed patients. Patients who experienced difficulty with their reconstruction noted more anxiety associated with media coverage


Sign in / Sign up

Export Citation Format

Share Document