scholarly journals Increased femoral neck cancellous bone and connectivity in coxarthrosis (hip osteoarthritis)

Bone ◽  
2003 ◽  
Vol 32 (1) ◽  
pp. 86-95 ◽  
Author(s):  
G.R Jordan ◽  
N Loveridge ◽  
K.L Bell ◽  
J Power ◽  
G.R Dickson ◽  
...  
2021 ◽  
pp. 112070002110130
Author(s):  
Leigh-Anne Tu ◽  
Douglas S Weinberg ◽  
Raymond W Liu

Background: While the influences of acetabular dysplasia and overcoverage on hip arthritis have been studied, the impact of femoral neck-shaft angle on hip arthritis is much more poorly understood. The purpose of this study is to determine if a relationship exists between neck shaft angle and the development of osteoarthritis, a better understanding of which would be useful to surgeons planning osteotomies about the hip. Methods: 533 cadaveric femora and acetabulae (1066 total) from the Hamann-Todd Osteological Collection (Cleveland, OH) were acquired. We measured true neck shaft angle using an AP photograph with the femoral neck parallel to the table. Femoral head volume to acetabular volume ratio, representing femoral head coverage, as well as femoral version were utilised. Correlation between neck shaft angle, femoral version, femoral head coverage and osteoarthritis were evaluated with multiple regression analysis. Results: The mean age and standard deviation was 56 ± 10 years. There were 64 females (12%) and 469 males. There were 380 Caucasians (71%) and 153 African-Americans. Mean femoral version was 11° ± 12° and mean true neck shaft angle was 127.7° ± 5.9° There was a strong correlation between age and arthritis (standardised beta 0.488, p < 0.001). There was a significant correlation between increasing true neck shaft angle and decreasing hip arthritis (standardised beta -0.024, p = 0.038). In the femoral head overcoverage subset, increasing true neck shaft angle was still significantly associated with decreasing hip arthritis (standardised beta −0.088, p = 0.018), although this relationship was not significant with femoral head undercoverage subset. Conclusions: With sufficient acetabular coverage, a relative increase in femoral neck shaft angle within the physiologic range is associated with decreased hip osteoarthritis. Clinical relevance: An understanding of the relationship between femoral neck shaft angle and hip osteoarthritis could be useful for surgeons planning pelvic or proximal femur osteotomies in children.


2012 ◽  
Vol 37 (1) ◽  
pp. 21-26 ◽  
Author(s):  
Marija Djuric ◽  
Slavisa Zagorac ◽  
Petar Milovanovic ◽  
Danijela Djonic ◽  
Slobodan Nikolic ◽  
...  

Bone ◽  
2018 ◽  
Vol 110 ◽  
pp. 326-334 ◽  
Author(s):  
Andreas Lodberg ◽  
Marco Eijken ◽  
Bram C.J. van der Eerden ◽  
Mette Wendelboe Okkels ◽  
Jesper Skovhus Thomsen ◽  
...  

2020 ◽  
Vol 9 (10) ◽  
pp. 205846012096491
Author(s):  
Mats Geijer ◽  
Sverrir Kiernan ◽  
Martin Sundberg ◽  
Gunnar Flivik

Background Restoration of a correct biomechanical situation after total hip arthroplasty is important. Purpose To evaluate proximal femoral symmetry of acetabular and femoral offset and femoral neck anteversion pre- and postoperatively in hip arthroplasty by semi-automated 3D-CT and to validate the software measurements by inter- and intraobserver agreement calculations. Material and Methods In low-dose CT on 71 patients before and after unilateral total hip arthroplasty, two observers used a digital 3D templating software to measure acetabular offset, true and functional femoral offset, and femoral neck anteversion. Observer agreements were calculated using intraclass correlation. Hip measurements were compared in each patient and between pre- and postoperative measurements. Results Preoperatively, acetabular offset (2.4 mm), true (2.2 mm), and functional global offset (2.7 mm) were significantly larger on the osteoarthritic side without side-to-side differences for true and functional femoral offset or femoral neck anteversion. Postoperatively, acetabular offset was significantly smaller on the operated side (2.1 mm) with a concomitantly increased true (2.5 mm) and functional femoral offset (1.5 mm), resulting in symmetric true and functional global offsets. There were no differences in postoperative femoral neck anteversion. Inter- and intraobserver agreements were near-perfect, ranging between 0.92 and 0.98 with narrow confidence intervals (0.77–0.98 to 0.94–0.99). Conclusion Acetabular and concomitantly global offset are generally increased in hip osteoarthritis. Postoperative acetabular offset was reduced, and femoral offset increased to maintain global offset. 3D measurements were reproducible with near-perfect observer agreements. 3D data sets should be used for pre- and postoperative measurements in hip arthroplasty.


Sign in / Sign up

Export Citation Format

Share Document