femoral neck anteversion
Recently Published Documents


TOTAL DOCUMENTS

69
(FIVE YEARS 12)

H-INDEX

16
(FIVE YEARS 0)

2021 ◽  
pp. 1-15
Author(s):  
Tomoharu Mochizuki ◽  
Takashi Sato ◽  
Ryota Katsumi

BACKGROUND: The association between the toe angle and bony rotational factors is critical to explain issues related to the onset and progression of knee osteoarthritis (OA). OBJECTIVE: The study aimed to clarify the association between the toe angle and each of the femoral and tibial transvers direction relative to gait direction, rotational knee alignment, and bony torsional deformity for the subjects with knee OA. METHODS: This study evaluated 58 knees in 24 healthy elderly (72 ± 5 years) and 34 varus knee OA (72 ± 6 years). A three-dimensional (3D) assessment system was used on 3D models and biplanar long-leg radiographs with the toe angle reflecting gait direction, applying a 3D-to-2D image registration technique. The main parameters on the transverse plane were: (1) toe angle, (2) transverse direction of the femur and tibia relative to the gait direction, (3) femoral neck anteversion, (4) condylar twist angle, (5) tibial torsion, and (6) rotational knee alignment. RESULTS: The alignment parameters, except for the tibial transverse direction, were different between healthy and osteoarthritic knees. In knee OA, the femoral neck anteversion - femoral transverse direction (p = 0.001), femoral transverse direction - tibial transverse direction (p < 0.001), and tibial transverse direction - toe angle (p < 0.001) were associated. CONCLUSIONS: The osteoarthritic knees showed that the femoral neck anteversion was associated with the femoral transverse direction, which determined the tibial transverse direction by adjusting the rotational knee alignment, leading to the toe angle.


2021 ◽  
Vol 86 ◽  
pp. 144-149
Author(s):  
Jessie Mackay ◽  
Pam Thomason ◽  
Morgan Sangeux ◽  
Elyse Passmore ◽  
Kate Francis ◽  
...  

2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Zhencun Cai ◽  
Chengzhe Piao ◽  
Tianyu Zhang ◽  
Lianyong Li ◽  
Liangbi Xiang

Abstract Background Accurate femoral neck anteversion angle (FNA) measurement is of great significance in the diagnosis and treatment of developmental dysplasia of the hip (DDH) in children. The FNA measurement still remains a controversy. We aimed to verify the accuracy of our CT method by 3D printing technology and to evaluate its clinical value. Methods Sixty-eight children with unilateral DDH were enrolled, and their FNA was measured using 2D-CT and 3D-CT, respectively, by three observers. This procedure was repeated 3 months later. The above measurement outcomes were then compared with the results in the 3D-printed femur (3D-PF) model. The FNA in the 3D-PF model was measured by three observers (two radiologists and one orthopedist; all were professors) collectively through electronic angle instrument. Results The primary measurement of FNA at the affected hips by 2D-CT was 44.0 ± 6.1, 49.5 ± 8.9, and 52.8 ± 7.9°, respectively. On the 3D-CT, it was 47.6 ± 5.4, 49.3 ± 6.8, and 48.6 ± 6.2°. Three months later, the FNA on 2D-CT was 49.3 ± 10.5, 42.8 ± 7.4, and 45.1 ± 9.3°, and it was 48.0 ± 6.5, 48.9 ± 7.2, and 49.0 ± 5.7° on 3D-CT, respectively. The FNA in the 3D-PF model at the affected and unaffected hips was 48.5 ± 6.6 and 36.9 ± 13.1°. There were significant differences between 2D-CT and 3D-PF measurements, but no significant difference was found between 3D-CT and 3D-PF measurements. The results by 2D-CT showed significant differences among groups and between the groups. However, the results by 3D-CT had no significant differences among groups or between the groups. Conclusion The results of our study showed that 3D-CT is a more precise, and reproducible method for FNA measurement in DDH. The FNA at the affected hips is 11.6° larger than the unaffected in DDH children aged 3–8 years.


2021 ◽  
Author(s):  
Zhencun Cai ◽  
Chengzhe Piao ◽  
Tianyu Zhang ◽  
Lianyong Li ◽  
Liangbi Xiang

Abstract Background: Accurate femoral neck anteversion angle (FNA) measurement is of great significance in the diagnosis and treatment of developmental dysplasia of the hip (DDH) in children. The FNA measurement still remains a controversy. We aimed to verify the accuracy of our CT method by 3D printing technology , and to evaluate its clinical value. Methods: Sixty-eight children with unilateral DDH were enrolled, and their FNA was measured using 2D-CT and 3D-CT, respectively, by three observers. This procedure was repeated 3 months later. The above measurement outcomes were then compared with the results in the 3D-printed femur (3D-PF) model. The FNA in the 3D-PF model was measured by three observers collectively through electronic angle instrument. Results: The primary measurement of FNA at the affected hips by 2D-CT was 44.0±6.1, 49.5±8.9 and 52.8±7.9 degrees, respectively. On the 3D-CT, it was 47.6±5.4, 49.3±6.8 and 48.6±6.2 degrees. Three months later, the FNA on 2D-CT was 49.3±10.5, 42.8±7.4 and 45.1±9.3 degrees, and it was 48.0±6.5, 48.9±7.2 and 49.0±5.7 degrees on 3D-CT, respectively. The FNA in the 3D-PF model at the affected and unaffected hips was 48.5±6.6 and 36.9±13.1 degrees. There were significant differences between 2D-CT and 3D-PF measurements, but no significant difference was found between 3D-CT and 3D-PF measurements. The results by 2D-CT showed significant differences among groups and between the groups. However, the results by 3D-CT had no significant differences among groups or between the groups. Conclusion: The results of our study showed that 3D-CT is a more precise, and reproducible method for FNA measurement in DDH. The FNA at the affected hips is 11.6 degree larger than the unaffected in DDH children aged 3-8 years.


Author(s):  
Hrvoje Mokrovic ◽  
Simona Komen ◽  
Leo Gulan ◽  
Gordan Gulan

Abstract Purpose The goal of total hip endoprosthesis is to achieve painless and functional hip for long term. Accurate reconstruction of hip anatomy largely depends on the implant design. In order to select an implant in correspondence with the native hip, the proximal femoral morphology has been in focus of many studies in the past years. The purpose of this study is to analyze proximal femoral geometry in the Croatian population by radiographic evaluation. Methods We conducted a retrospective study analyzing conventional radiographies of the hip, obtained within the last four years from the database of Clinic for Orthopaedic Surgery Lovran. The number of studied patients was 300,168 women and 132 men. The proximal femoral geometric parameters assessed were as follows: femoral head diameter, femoral neck length, neck-shaft angle, angle of femoral neck anteversion, and lateral femoral offset. The results obtained were compared between genders and with results of other studies. Results Proximal femoral anatomy differed in femoral head diameter and lateral femoral offset between males and females in our group of patients, while femoral neck length, femoral neck shaft angle, and femoral neck anteversion have shown similar values in both genders. Our study also showed specificity of the Croatian population in almost all parameters of proximal femoral anatomy, in comparison with other ethnic groups. Conclusion Our results support the observation on high diversity in the morphology of the proximal femur and the specificity of the proximal femoral anatomy of the Croatian population.


2020 ◽  
Vol 9 (10) ◽  
pp. 205846012096491
Author(s):  
Mats Geijer ◽  
Sverrir Kiernan ◽  
Martin Sundberg ◽  
Gunnar Flivik

Background Restoration of a correct biomechanical situation after total hip arthroplasty is important. Purpose To evaluate proximal femoral symmetry of acetabular and femoral offset and femoral neck anteversion pre- and postoperatively in hip arthroplasty by semi-automated 3D-CT and to validate the software measurements by inter- and intraobserver agreement calculations. Material and Methods In low-dose CT on 71 patients before and after unilateral total hip arthroplasty, two observers used a digital 3D templating software to measure acetabular offset, true and functional femoral offset, and femoral neck anteversion. Observer agreements were calculated using intraclass correlation. Hip measurements were compared in each patient and between pre- and postoperative measurements. Results Preoperatively, acetabular offset (2.4 mm), true (2.2 mm), and functional global offset (2.7 mm) were significantly larger on the osteoarthritic side without side-to-side differences for true and functional femoral offset or femoral neck anteversion. Postoperatively, acetabular offset was significantly smaller on the operated side (2.1 mm) with a concomitantly increased true (2.5 mm) and functional femoral offset (1.5 mm), resulting in symmetric true and functional global offsets. There were no differences in postoperative femoral neck anteversion. Inter- and intraobserver agreements were near-perfect, ranging between 0.92 and 0.98 with narrow confidence intervals (0.77–0.98 to 0.94–0.99). Conclusion Acetabular and concomitantly global offset are generally increased in hip osteoarthritis. Postoperative acetabular offset was reduced, and femoral offset increased to maintain global offset. 3D measurements were reproducible with near-perfect observer agreements. 3D data sets should be used for pre- and postoperative measurements in hip arthroplasty.


2020 ◽  
Vol 2020 ◽  
pp. 1-5
Author(s):  
Yosuke Iwamoto ◽  
Hiroaki Kijima ◽  
Hiroshi Tazawa ◽  
Natsuo Konishi ◽  
Hitoshi Kubota ◽  
...  

Background. Because the tapered wedge-shaped type cementless stem has a small anteroposterior width and a low occupation rate in the medullary space, postoperative rotational instability and stem subsidence due to inadequate proximal fixation are concerns. The purpose of this study was to clarify the relationship between the rotational instability of the tapered wedge-shaped type cementless stem and femoral canal shape. Methods. A total of 61 primary total hip arthroplasties with the tapered wedge-shaped type cementless stem Accolade® TMZF (11 males, 50 females; mean age 60 years) from January 2012 to June 2015 who underwent computed tomography before surgery and within 4 weeks and 1 year after surgery were evaluated. The preoperative femoral neck anteversion angle, preoperative femoral canal flair index, the degree of postoperative stem subsidence within 1 year after operation, and the degree of rotational change in the stem setting angle within 1 year after operation were investigated. Results. The mean preoperative femoral neck anteversion angle was 32.2° ± 17.8° (0°–69°), and the mean preoperative canal flair index was 3.68 ± 0.58 (2.44–5.55). There were no stem subsidence cases within 1 year after operation. The mean degree of rotational change in the stem from immediately to 1 year after surgery was −0.4° ± 1.7° (−3°–3°). There was no significant correlation between the canal flair index and the rotational change in the stem. In addition, the mean difference between the preoperative femoral neck anteversion angle and the stem rotational angle immediately after surgery was only 1.3° ± 5.3° (−29°–15°). Conclusions. In all cases, including stove-pipe cases, the degree of rotational change in the Accolade® TMZF stem from immediately to 1 year after surgery was within 3°. In other words, regardless of femoral canal shape, the tapered wedge-shaped type cementless stem has little initial rotational instability.


2020 ◽  
Author(s):  
Christine M. Harper ◽  
Adam D. Sylvester ◽  
Robert K. McAfee ◽  
Siobhán B. Cooke