Voltage mapping to guide pacemaker placement in patients with CHD

2019 ◽  
Vol 29 (10) ◽  
pp. 1313-1316
Author(s):  
Soham Dasgupta ◽  
Peter Fischbach ◽  
Robert Whitehill

AbstractTransvenous pacemaker implantation for sinus node dysfunction in patients with Fontan palliation presents the difficulty of finding suitable pacing tissue and the potential of causing vascular obstruction in a low-flow circuit. We describe a patient who underwent electro-anatomic voltage mapping to guide a transvenous single chamber lead within her Fontan baffle. This highlights the use of advanced mapping technologies for pacemaker implantation in complex cyanotic heart disease.

2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
T Kondo ◽  
M Kimura ◽  
M Nakayama ◽  
O Matsuda

Abstract Background Although sinus node dysfunction (SND) coexists with atrial fibrillation (AF) in some cases, SND in patients with Non-paroxysmal AF (Non-PAF) could not be estimated in conventional electrophysiological study. Atrial low voltage zone (LVZ), which may be surrogate for atrial fibrosis, is although reported to present in patients with Non-PAF, the association between SND and right atrial LVZ (RA-LVZ) has not been fully evaluated. The aim of the present study was to assess the relationship between SND and RA-LVZ in patients with Non-PAF. Method Eighty-six Non-PAF patients underwent high density voltage mapping of right atrium (RA) during AF before ablation procedure. We defined LVZ as that with electrogram amplitude <0.1 mV in order to delineate strongly damaged area in RA. We evaluated the surface are of the RA-LVZ in Non-PAF patients with and without SND. Results Twenty-seven of 86 patients (31.4%) presented with SND after AF termination. There were no significant differences between patients with and without SND in variables such as age, sex, AF duration, left atrial diameter, and left ventricular ejection fraction. The mean value of RA-LVZ of all the patients was 12.1±11.4%, and RA-LVZ was significantly larger in patients with SND than in those without SND (22.8±14.6 vs 7.2±4.2%; P<0.001). In multivariate logistic regression analysis for the incidence of subsequent pacemaker implantation (PMI), only RA-LVZ was a significant predictor of subsequent PMI (odd ratio 1.306; 95% confidence interval 1.159 - 1.473; P<0.001). Receiving-operating characteristic curve for PMI following ablation procedure indicated cut-off value 10.5% for RA-LVZ with 85.2% sensitivity and 88.1% specificity (area under curve = 0.924, P<0.001). Kaplan-Meier analysis of the incidence of PMI after AF termination showed that freedom from pacemaker implantation was significantly better in patients with RA-LVA <10.5% than in those with RA-LVZ ≥10.5% (log-rank test; P<0.001). Conclusions Broad RA-LVZ measured during AF was strongly associated with SND and PMI after AF termination in patients with Non-PAF. Evaluation of RA-LVZ during AF could be a potential target in predicting SND requiring PMI in patients with Non-PAF.


EP Europace ◽  
2016 ◽  
Vol 19 (7) ◽  
pp. 1220-1226 ◽  
Author(s):  
Roman Brenner ◽  
Peter Ammann ◽  
See-Il Yoon ◽  
Stefan Christen ◽  
Jens Hellermann ◽  
...  

2018 ◽  
Vol 71 (11) ◽  
pp. A623
Author(s):  
Jerry Michael ◽  
Barbara Burkhardt ◽  
William Scott ◽  
Ilana Zeltser ◽  
Franz Gerald Greil ◽  
...  

2019 ◽  
Author(s):  
Qi Xue ◽  
Hai Zou ◽  
Lihong Wang ◽  
Hong Shao ◽  
Yuan Ma

Abstract Background: Patients implanted with pacemakers frequently develop atrial fibrillation. Pacemaker-detected atrial high-rate episodes or AHREs, where one AHRE is defined as ≥ 160beats/min lasting ≥ 5 minutes, may identify patients at increased risk for stroke and death. In this study, we sought to observe whether patients with sinus node dysfunction or atria-ventricular block are more likely to develop AHREs. Methods: A total of 103 patients (age 69.4±13.5 years,58% female) with DDD/DDDR pacemakers were enrolled for the study. These pacemakers were equipped with features that enabled the detection and storage of information such as the dates, durations and sequential episodes of AHRE. Patients were followed up for 2 years and the time of the first occurrence of AHRE was determined at follow-up visit. Other data such as age, gender, structural heart disease, concomitant non-cardiac diseases, the cumulative percentage of atrial pacing (Cum% AP) and ventricular pacing (Cum% VP) were also collected. Results: Atrial fibrillation developed frequently after the dual-chamber pacemaker implantation. AHRE occurred more often in patients with sinus node disease (SND) than those with atrioventricular block (AVB) (OR, 2.553; 95%CI, 1.122-5.814;P=0.045). Conclusions: AHRE developed frequently after dual-chamber pacemaker implantation. Patients with SND are more likely to develop AF compared to the patients with AVB.


EP Europace ◽  
2005 ◽  
Vol 7 (Supplement_1) ◽  
pp. 174-174
Author(s):  
K.J. Ko ◽  
H.E. Lim ◽  
H.N. Pak ◽  
H.S. Lee ◽  
J.H. Jin ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document