3D Non-Destructive Identification of Fossil Fish from the Late Cretaceous of Alberta, Canada using Synchrotron Micro Computed Tomography

2021 ◽  
Vol 29 (2) ◽  
pp. 26-31
Author(s):  
Don Brinkman ◽  
Lisa L. Van Loon ◽  
Neil R. Banerjee

2020 ◽  
Vol 26 (S2) ◽  
pp. 1252-1254
Author(s):  
Lisa Van Loon ◽  
Neil Banerjee ◽  
Don Brinkman

2015 ◽  
Vol 73 (3) ◽  
Author(s):  
Jaafar Abdullah ◽  
Abibullah Samsudin ◽  
Nor Laili Omar ◽  
Hafizza Abdul Manan

Determining the fineness of gold jewelleries remains one of the most challenging tasks in gold trading. The existing technology of gold testing is inadequate, allowing gold counterfeiting worldwide. The most popular non-destructive method for analysis of gold jewelleries is X-ray fluorescence technique. However, the technique is limited to surface only and it is also greatly influenced by matrix effects. In this paper, dual-energy X-ray micro-computed tomography method was proposed to assay gold jewelleries. Experimental results demonstrated that grey values of reconstructed tomographic images in combination with advanced image analysis procedures could be used to detect fake jewelleries. Due to the uniqueness of X-ray absorption, the technique was also capable of identifying different materials in gold jewelleries. Further analysis on sectioned-earrings samples using X-ray diffraction techniques and visual observation confirmed all tomographic findings.  


2019 ◽  
Vol 34 (9) ◽  
pp. 2111-2117 ◽  
Author(s):  
Klemens Trieb ◽  
Jonathan Glinz ◽  
Michael Reiter ◽  
Johann Kastner ◽  
Sascha Senck

2020 ◽  
Vol 27 (4) ◽  
pp. 1015-1022 ◽  
Author(s):  
Ana Prates Soares ◽  
Uwe Blunck ◽  
Kerstin Bitter ◽  
Sebastian Paris ◽  
Alexander Rack ◽  
...  

Bonding of resin composite fillings, for example following root-canal treatment, is a challenge because remaining gaps grow and lead to failure. Here, phase-contrast-enhanced micro-computed tomography (PCE-CT) is used to explore methods of non-destructive quantification of the problem, so that countermeasures can be devised. Five human central incisors with damaged crowns were root-filled followed by restoration with a dental post. Thereafter, the crowns were rebuilt with a resin composite that was bonded conventionally to the tooth with a dental adhesive system (Futurabond U). Each sample was imaged by PCE-CT in a synchrotron facility (ID19, European Synchrotron Radiation Facility) with a pixel size of 650 nm. The reconstructed datasets from each sample were segmented and analysed in a semi-automated manner using ImageJ. PCE-CT at sub-micrometre resolution provided images with an impressive increased contrast and detail when compared with laboratory micro-computed tomography. The interface between the dental adhesive and the tooth was often strongly disrupted by the presence of large debonded gaps (on average 34% ± 15% on all surfaces). The thickness of the gaps spanned 2 µm to 16 µm. There was a large variability in the distribution of gaps within the bonding area in each sample, with some regions around the canal exhibiting up to 100% discontinuity. Although only several micrometres thick, the extensive wide gaps may serve as gateways to biofilm leakage, leading to failure of the restorations. They can also act as stress-raising `cracks' that are likely to expand over time in response to cyclic mechanical loading as a consequence of mastication. The observations here show how PCE-CT can be used as a non-destructive quantitative tool for understanding and improving the performance of clinically used bonded dental restorations.


Sign in / Sign up

Export Citation Format

Share Document