tomography method
Recently Published Documents


TOTAL DOCUMENTS

357
(FIVE YEARS 107)

H-INDEX

25
(FIVE YEARS 4)

2022 ◽  
Author(s):  
Shinya Iwasaki ◽  
Lester Lembke-Jene ◽  
Kana Nagashima ◽  
Helge Arz ◽  
Naomi Harada ◽  
...  

Abstract Southern Ocean deep-water circulation plays an important role in the global carbon cycle. On geological time-scales, upwelling along the Chilean continental margin likely contributed to the deglacial atmospheric carbon dioxide rise, but little quantitative evidence exists of carbon storage. Here, we use a new X-ray Micro-Computer-Tomography method to assess foraminiferal test dissolution as proxy for paleo-carbonate ion concentrations ([CO32−]). Our subantarctic Southeast Pacific sediment core depth transect shows significant deep-water [CO32−] variations during the Last Glacial Maximum and Deglaciation (10 – 22 ka BP). We provide evidence for an increase in [CO32−] during the early deglacial period (15-19 ka BP), followed by a ca. 40 µmol kg−1 reduction in Lower Circumpolar Deepwater (CDW). This decreased Pacific to Atlantic export of low-carbon CDW contributed to significantly lowered carbon storage within the Southern Ocean, highlighting the importance of a dynamic Pacific–Southern Ocean deep-water reconfiguration for shaping late-glacial oceanic carbon storage, and subsequent deglacial oceanic-atmospheric CO2 transfer.


2021 ◽  
Vol 13 (3) ◽  
pp. 219-225
Author(s):  
Haocai Huang ◽  
Xinyi Xie ◽  
Shijie Xu ◽  
Yong Guo ◽  
Shuo Liu ◽  
...  

2021 ◽  
Vol 6 (24) ◽  
pp. 152-160
Author(s):  
Siti Syukriah Khamdan ◽  
Tajul Ariffin Musa ◽  
Suhaila M. Buhari

This paper presents the detection of the equatorial plasma bubbles (EPB) using the Global Positioning System (GPS) ionospheric tomography method over Peninsular Malaysia. This paper aims to investigate the capability of the GPS ionospheric tomography method in detecting the variations of the EPB over the study area. In doing so, a previous case study during post-sunset 5th April 2011 has been selected as a reference for the detection of the EPBs over the study area. It has been observed that at least three structures of the EPBs have been captured based on the rate of change total electron content (TEC) index (ROTI) from 12 UT until 19 UT. Therefore, the three-dimensional ionospheric profiles have been reconstructed over Peninsular Malaysia using the tomography method during the study period in order to capture the signature of the EPBs. In this study, the detection of the EPBs using the tomography method is based on the rate of change of electron density (ROTNe). The results from three-dimensional ionospheric tomography show only two structures of EPBs are detected during the study period. It has been observed that the ROTNe depleted up to ~-12x109el/cm. Overall, the results in this study show that the GPS ionospheric tomography capable to be utilized in detecting the variations of EPBs in support of ionospheric studies and monitoring in the Malaysian region.


2021 ◽  
Vol 95 (12) ◽  
Author(s):  
Wenyuan Zhang ◽  
Shubi Zhang ◽  
Guobin Chang ◽  
Nan Ding ◽  
Xiaoming Wang
Keyword(s):  
The Real ◽  

Sensors ◽  
2021 ◽  
Vol 21 (22) ◽  
pp. 7448
Author(s):  
Shijie Xu ◽  
Zhao Xue ◽  
Xinyi Xie ◽  
Haocai Huang ◽  
Guangming Li

Continuous sensing of water parameters is of great importance to fluid dynamic progress study in oceans, coastal areas and inland waters. The acoustic tomography technique can perform water temperature field measurements horizontally and vertically using sound wave travel information. The layer-averaged water temperature can also be measured with the acoustic tomography method. However, investigations focusing on the stratified mechanism, which consists of stratification form and its influence on inversion error, are seldom performed. In this study, an acoustic tomography experiment was carried out in a reservoir along two vertical slices to observe the layer-averaged water temperature. Specifically, multi-path sound travel information is identified through ray tracing using high-precision topography data obtained via a ship-mounted ADCP during the experiment. Vertical slices between sound stations are divided into different layers to study layer division inversion methods in different preset types. The inversion method is used to calculate the average water temperature and inversion temperature error of every layer. Different layer methods are studied with a comparison of results. The layer division principle studied in this paper can be used for layer-averaged water temperature sensing with multi-path sound transmission information.


2021 ◽  
Vol 2103 (1) ◽  
pp. 012024
Author(s):  
A A Sharafutdinova ◽  
A O Andreev ◽  
Y A Nefedyev ◽  
R Hudec ◽  
N Y Demina

Abstract The work is focused on the analysis of modern observations of meteoroids included in the data bank formed by both professional researchers and amateur astronomers. Based on the modern physical theory of meteoroids (PTM), a new method for analyzing measurements developed, which provides the accuracy comparable with the results of radar observations. Due to the fact that the accuracy of the new method for analyzing meteoroids observations has increased significantly, it became possible to process observations of the Perseid and Leonid showers over a period of 120 years. The use of PTM made it possible for the first time to explain the distribution of meteor echo signals observed at an altitude of 2 MHz, at which the upper part of this distribution refers to an altitude of 140 km. In the process of work, a database of orbital characteristics of meteoroids was created. A method has been developed for modeling the probability of hitting a certain area of a meteor particle with a mass greater than a certain specified value and determining the density of a meteor shower from radio observations as well as a new “tomography” method for calculating the density distribution of sporadic meteors in the sky using radar observations of meteors at the same station with a goniometer. The method allows calculating the density of a meteor shower on the celestial sphere with an angular resolution of 2°. The use of these methods served as a proof that the distribution density of meteoroid showers on the celestial sphere has two planes of symmetry: the first coincides with the plane of the ecliptic, passing through the poles of the Earth, the other one is perpendicular to the plane of the ecliptic.


Water ◽  
2021 ◽  
Vol 13 (21) ◽  
pp. 2981
Author(s):  
Tomisław Gołębiowski ◽  
Bogdan Piwakowski ◽  
Michał Ćwiklik ◽  
Antoni Bojarski

The paper presents the results of geophysical measurements that were carried out in the vicinity of the water dam/water reservoir supplying the city of Bielsko-Biala with drinking water. The measurements were performed in order to non-invasively detect faults, fractured zones and areas filled with breccia, which may be, at the same time, a preferential path of groundwater flow. The aforementioned factors influence the stability of the dam. The general identification of the examined media was realized by the electrical resistivity tomography method. The ERT surveys were supplemented by capacitively-coupled resistivity. The electrical methods allowed them to recognize geological settings, indicate possible fault locations, and point out the fault plane as a path of water flow. The ground penetrating radar method detected fractured and filled water areas and underground water paths in the dam’s forefield as a result of the method’s very high resolution. The high resolution seismic reflection method provided a clear and high resolution image of the relatively deep geological structure and verified a location and the run of the faults. In general, the complex geophysical-geological interpretation enabled classification of the unconsolidated/fractured zones associated with faults as a place where the erosion process is the most intense and can bring danger on the dam. Finally, it was confirmed that the area should be the subject of geophysical monitoring.


Author(s):  
CHANGLE LI ◽  
ZEQUN LI ◽  
XUEHE ZHANG ◽  
GANGFENG LIU ◽  
JIE ZHAO

Traditional manual puncture surgery has low positioning accuracy and poor stability. Moreover, the computed tomography method can cause strong radiation damage. Therefore, this study intends to establish a robotic system in puncture surgery, which is based on optical registration to improve safety, accuracy, and efficiency. As the accuracy of surgical space calibration influences the accuracy of the surgical system, this study proposes an improved automatic calibration algorithm for linear rotation. The algorithm can reduce error caused by manual calibration and system noise. Recalibration is not required provided that the pose of the digital reference frame is unchanged, thereby improving accuracy and efficiency. The proposed algorithm is experimentally verified to prove its effectiveness. Results show that the average errors of position and posture are 0.25[Formula: see text]mm and 0.2∘, respectively. The accuracy of calibration fully meets the needs of surgery.


Sign in / Sign up

Export Citation Format

Share Document