Biotransformation of Current-Use Progestin Dienogest and Drospirenone in Laboratory-Scale Activated Sludge Systems Forms High-Yield Products with Altered Endocrine Activity

Author(s):  
Haoqi Nina Zhao ◽  
Zhenyu Tian ◽  
Kelly E. Kim ◽  
Rui Wang ◽  
Kenji Lam ◽  
...  
2002 ◽  
Vol 46 (1-2) ◽  
pp. 19-27 ◽  
Author(s):  
K. Kaewpipat ◽  
C.P.L. Grady

As a first step in understanding nonlinear dynamics in activated sludge systems, two laboratory-scale sequencing batch reactors were operated under identical conditions and changes in their microbial communities were followed through microscopic examination, macroscopic observation, and denaturing gradient gel electrophoresis (DGGE) of PCR-amplified 16S rRNA gene segments from the prokaryotic community. Two experiments were performed. The first used activated sludge from a local wastewater treatment plant to start the replicate reactors. The second used the biomass from the first experiment as a source by intermixing the two and equally redistributing the biomass into the two replicate reactors. For both experiments, the two reactors behaved fairly similarly and had similar microbial communities for a period of 60 days following start-up. Beyond that, the microbial communities in the two reactors in the first experiment diverged in composition, while those in the second experiment remained fairly similar. This suggests that the degree of change occurring in replicate reactors depends upon the severity of perturbation to which they are exposed. The DGGE data showed that the bacterial communities in both experiments were highly dynamic, even though the system performance of the replicate reactors were very similar, suggesting that dynamics within the prokaryotic community is not necessarily reflected in system performance. Moreover, a significant finding from this study is that replicate activated sludge systems are not identical, although they can be very similar if started appropriately.


1989 ◽  
Vol 21 (4-5) ◽  
pp. 29-41 ◽  
Author(s):  
D. M. D. Gabb ◽  
G. A. Ekama ◽  
D. Jenkins ◽  
G. v. R. Marais

Bulking in activated sludge systems due to proliferation of Sphaerotilus natans is very common in laboratory-scale but rare in full-scale systems. From two laboratory-scale studies it is concluded that a cause for proliferation was attached growth of S.natans on the walls of the feed lines and reactor surfaces continuously seeding the mixed liquor. It is suggested that S.natans bulking in laboratory-scale systems is common compared to full-scale systems because the surface area/volume ratio of the former is orders of magnitude higher than that of the latter so that the potential for seeding from attached growths in laboratory-scale plants is correspondingly higher. It would appear that in laboratory-scale activated sludge systems regular cleaning of the feed lines and daily scrubbing of the reactor and other wetted surfaces will eliminate S.natans bulking due to seeding of the mixed liquor from these surfaces.


1977 ◽  
Vol 12 (1) ◽  
pp. 191-212
Author(s):  
B. Volesky ◽  
Q. Samak ◽  
P. Waller

Abstract Review of the available results appearing in the recent literature is presented focusing particularly upon the effects of metallic ions such as Cr, Cu, Zn, Cd, Hg, V, Zn, Ni and Co. Some original data involving the effects of Na are presented and discussed. Development of parameters used in evaluating the influence of toxic or inhibitory species on the mixed microbial population of an activated sludge system is of crucial importance and different techniques employed such as BOD-COD-TOC-removal rates, Oxygen Uptake Rate, and others are discussed, showing relative inadequacy of currently applied assays. From the data available, certain trends can be discerned. There is a definite threshold concentration for each metallic ion, depending on the organic load of the feed. In the order of increasing toxicity to activated sludge systems reflected in lower BOD removals the following metals have been listed as inhibiting factors at concentrations starting from 1 ppm applied on a continuous basis: hexavalent chromium, cobalt, zinc, cadmium, trivalent chromium, copper and nickel. Metals in combination have not been reported to exhibit any significantly different effects as compared to those observed with individually introduced metallic ions. Tolerance of some activated sludge systems to shock loadings by various inorganic ions and metals is reviewed. The conclusions are of particular importance for estimating the performance of biox systems handling industrial effluents which are likely to contain toxic components of inorganic or metallic nature.


1991 ◽  
Vol 24 (7) ◽  
pp. 59-64 ◽  
Author(s):  
R. W. Szetela

Steady-state models are presented to describe the wastewater treatment process in two activated sludge systems. One of these makes use of a single complete-mix reactor; the other one involves two complete-mix reactors arranged in series. The in-series system is equivalent to what is known as the “two-phase” activated sludge, a concept which is now being launched throughout Poland in conjunction with the PROMLECZ technology under implementation. Analysis of the mathematical models has revealed the following: (1) treatment efficiency, excess sludge production, energy consumption, and the degree of sludge stabilization are identical in the two systems; (2) there exists a technological equivalence of “two-phase” sludge with “single-phase” sludge; (3) the “two-phase” system has no technological advantage over the “single-phase” system.


1989 ◽  
Vol 21 (6-7) ◽  
pp. 609-619 ◽  
Author(s):  
Y.-J. Shao ◽  
David Jenkins

Laboratory and pilot plant experiments on anoxic selector activated sludge systems were conducted on two wastewaters in some cases supplemented with nitrate, acetate or glucose. To prevent bulking sufficient anoxic selector detention time and nitrate levels must be available to reduce selector effluent soluble COD to below 100 mg/l and to reduce readily metabolizable organic matter to virtually zero (< 1 mg/l). Soluble COD/NO3-N removal stoichiometry is in the range 6.0-6.7. Selector systems have elevated soluble substrate removal and denitrification rates compared to CSTR systems. These rates are not affected greatly by temperature (20-25°C) for CSTR sludges but are for selector sludges. Upon exhaustion of nitrate in a selector soluble COD leaks out of the activated sludge in significant amounts. Thiothrix sp. and type 021N denitrify only to NO2 and at much slower rates than Zoogloearamigera does to N2. A sequencing batch system provides an optimistic estimate of the SVI that can be obtained by an anoxic selector system.


1994 ◽  
Vol 30 (11) ◽  
pp. 255-261 ◽  
Author(s):  
Barth F. Smets ◽  
Timothy G. Ellis ◽  
Stephanie Brau ◽  
Richard W. Sanders ◽  
C. P. Leslie Grady

This study quantified the kinetic differences in microbial communities isolated from completely mixed activated sludge (CMAS) systems that were operated either with or without an aerobic selector preceding the main reactor. A new respirometric method was employed that allowed the determination of biodegradation kinetics from single oxygen consumption curves, thereby minimizing physiological changes to the examined communities during the assay. Results indicated that increased values for Ks and μmax for acetate, phenol, and 4-chlorophenol degradation were measured in the CMAS system operated with a selector. The biomass yields on acetate, phenol, and 4-chlorophenol were very similar in both systems. These findings indicate that the operation of CMAS systems with aerobic selectors may result in the selection for degrading populations with higher Ks and μmax values for both biogenic and xenobiotic organic compounds, and that substrate storage in the selector only partially contributes to increased substrate removal rates.


1993 ◽  
Vol 28 (10) ◽  
pp. 309-316
Author(s):  
Bilsen Beler Baykal

Small activated sludge systems operate in transient states under intermittent and variable flows. Simulations for such a treatment plant in a summer house site operating on a seasonal basis is investigated for system performance and viability using the five component inert soluble substrate generation model. The results have revealed that the viability drops to zero within the first month after the cessation of the feed for intermittently loaded systems that are fed during the summer months, while it never reaches that value for systems operating all year round with reduced flows off season. Restartup is compulsory for the intermittent loadings while the system adapts itself in a stepwise manner for the year round operation. Other factors being comparable, conventional operation with shorter sludge ages may be preferable since viability of the sludge is higher and the effluent COD is comparable.


Sign in / Sign up

Export Citation Format

Share Document