New hydrophilicity scale derived from high-performance liquid chromatography peptide retention data: correlation of predicted surface residues with antigenicity and x-ray-derived accessible sites

Biochemistry ◽  
1986 ◽  
Vol 25 (19) ◽  
pp. 5425-5432 ◽  
Author(s):  
J. M. R. Parker ◽  
D. Guo ◽  
R. S. Hodges
2021 ◽  
pp. 67-75

Eight historical textile objects belonging to the 16th-20th centuries in the collection of the Topkapi Palace Museum in Istanbul were analyzed with the purpose of reaching improved conservation and restoration methods. The historical textiles underwent dyestuff analysis by High Performance Liquid Chromatography, morphological and elemental analysis by Scanning Electron Microscope with energy Dispersive X-ray Spectroscopy, CIEL*a*b color measurement as well as technical analysis by optical microscopy.


2021 ◽  
Vol 4 (02) ◽  
pp. 5-24
Author(s):  
Fatemeh Pourbahman ◽  
Mohsen Zeeb ◽  
Amirhossein Monzavi ◽  
Zahra Khodadadi ◽  
Seyed Saied Homami

A nanohybrid material termed graphene oxide/metal-organic framework-74/Fe3O4/polytyramine (GO/MOF-74/Fe3O4­/PTy) was fabricated and applied in magnetic dispersive micro-solid phase extraction (MD-µ-SPE) coupled with high performance liquid chromatography (HPLC) for simultaneous determination of fluoroquinolones compounds including, ofloxacin, ciprofloxacin, lomefloxacin, enrofloxacin and sperfloxacin in egg samples. The GO/MOF-74/Fe3O4/PTy nanocomposite was fabricated through an in situ synthesis of MOF-74 in the presence of magnetic GO and followed with an oxidative polymerization of tyramine using horsedish peroxide (HRP) enzyme. The modifier agents improved the merits of the nanoporous sorbent. Extraction protocols based on GO/MOF nanocomposites have various benefit such as, the high stability, the tunable porosity, the fast mast transfer and reasonable enrichment factor. The fabricated material was characterized via energy dispersive x-ray analysis (EDX), the scanning electron microscopy (SEM), Fourier-transform infrared spectroscopy (FT-IR), and the x-ray diffraction (XRD). The calibration curves revealed linearity (0.992 ≤ r2 ≤ 0.997) in the ranges of 1.0-475.0, 0.5-350.0, 0.5-350.0, 0.5-375.0 and 1.5-300.0 ng mL-1 with limit of detections (LODs, S/N=3) of 0.3, 0.1, 0.2, 0.1 and 0.4 ng mL-1 for ofloxacin, ciprofloxacin, lomefloxacin, enrofloxacin and sperfloxacin, respectively. The intra-assay (≤7.7%, n = 9) and inter-assay (≤7.0%, n = 9) precisions along with accuracy less than 9.0% were obtained.


Sign in / Sign up

Export Citation Format

Share Document