Simultaneous Determination of Multiple (Fluoro)quinolone Antibiotics in Food Samples by a One-Step Fluorescence Polarization Immunoassay

2013 ◽  
Vol 61 (39) ◽  
pp. 9347-9355 ◽  
Author(s):  
Tiejun Mi ◽  
Zhanhui Wang ◽  
Sergei A. Eremin ◽  
Jianzhong Shen ◽  
Suxia Zhang
2005 ◽  
Vol 2 (3) ◽  
pp. 227 ◽  
Author(s):  
Sergei A. Eremin ◽  
Dietmar Knopp ◽  
Reinhard Niessner ◽  
Ji Youn Hong ◽  
Song-Ja Park ◽  
...  

Environmental Context.Benzene, toluene, ethylbenzene, and xylenes (BTEX) are used as solvents in paints and coatings and are constituents of petroleum products. BTEX can contaminate air, water or soil and is toxic; benzene, in particular, is a recognized human carcinogen. Most existing methods for detecting BTEX are time-consuming, complicated and very expensive for routine screening. A rapid immunoassay of BTEX is presented that greatly simplifies environmental monitoring of water contamination. Abstract.For the rapid screening of BTEX (benzene, toluene, ethylbenzene, xylenes), a fluorescence polarization immunoassay (FPIA) was developed using the fluorescence polarization analyzer Abbott TDx. Several fluorescence-labelled tracers were synthesized by binding ethylenediamine fluorescein thiocarbamyl (EDF) to various substituted phenylcarboxylic acids. The binding of 27 tracers with two antisera that can be considered as class-specific for BTEX was investigated to select optimal tracer–antibody pairs. Significant differences were found in binding, titer, sensitivity, and assay kinetics. A best pair of anti-BTEX antiserum and EDF-labelled p-tolylacetic acid tracer was selected for FPIA. To simplify the method, an immunocomplex single reagent was prepared to detect BTEX by a one-step FPIA. One-step FPIA is a rapid homogeneous type of immunoassay that has only one pipetting step, does not need separation of free and bound analyte and can be performed at room temperature. The within-run coefficient of variation was ranged between 3.4% and 5.7%. Furthermore, if the measurement can be done at constant temperature, standards for every assay run are unnecessary. Cross-reactivity studies of petroleum compounds and a BTEX mixture indicated that p-xylene was most reactive with a limit of detection (LOD) of 0.22 µg mL−1 in 50 µL of sample. The LOD for toluene and benzene was 2.1 and 11 µg mL−1 respectively. The immunocomplex single reagent has proven to be significantly more stable than the corresponding solutions of antibody and tracer.


2014 ◽  
Vol 6 (11) ◽  
pp. 3849-3857 ◽  
Author(s):  
Tiejun Mi ◽  
Xiao Liang ◽  
Long Ding ◽  
Suxia Zhang ◽  
Sergei A. Eremin ◽  
...  

Rapid determination of orbifloxacin residue in milk by an optimized fluorescence polarization immunoassay based on a heterogeneous fluorescent tracer.


2005 ◽  
Vol 49 (8) ◽  
pp. 3569-3571 ◽  
Author(s):  
GholamAli Khoschsorur ◽  
Franz Fruehwirth ◽  
Sieglinde Zelzer

ABSTRACT A simple, specific method is presented for simultaneous determination of voriconazole and itraconazole and its metabolite, hydroxyitraconazole, in human serum using one-step liquid-liquid extraction and high-performance liquid chromatography. Linearity tests ranged from 0.1 to 8.0 μg/ml; the minimum detectable concentration was 0.03 μg/ml.


2018 ◽  
Vol 250 ◽  
pp. 7-13 ◽  
Author(s):  
Wesley Pereira da Silva ◽  
Luiz Henrique de Oliveira ◽  
André Luiz dos Santos ◽  
Valdir Souza Ferreira ◽  
Magno Aparecido Gonçalves Trindade

Sign in / Sign up

Export Citation Format

Share Document