scholarly journals Analysis of Individual Positron Emission Tomography Activation Maps by Detection of High Signal-to-Noise-Ratio Pixel Clusters

1993 ◽  
Vol 13 (3) ◽  
pp. 425-437 ◽  
Author(s):  
Jean-Baptiste Poline ◽  
Bernard M. Mazoyer

We present a new method for the analysis of individual brain positron emission tomography (PET) activation maps that looks for activated areas of a certain size rather than pixels with maximum values. High signal-to-noise-ratio pixel clusters (HSC) are identified and their sizes are statistically tested with respect to a Monte-Carlo–derived distribution of cluster sizes in pure noise images. From multiple HSC size tests, a strategy is proposed for control of the overall type I error. The sensitivity and specificity of this method have been assessed using realistic Monte Carlo simulations of brain activation maps. When compared with the γ2 statistic of the local maxima distribution, the proposed method showed enhanced sensitivity, particularly for signals of low magnitude and/or large size. Its potential for the individual analysis of PET activation studies is presented in two sets of subjects who underwent two cognitive protocols. Although it can be viewed as an alternative to the classical stereotactic averaging approach, this new method is intended to be a first step toward the analysis of single-subject PET activation studies.

Nanophotonics ◽  
2020 ◽  
Vol 9 (10) ◽  
pp. 3443-3450 ◽  
Author(s):  
Wei-Nan Liu ◽  
Rui Chen ◽  
Wei-Yi Shi ◽  
Ke-Bo Zeng ◽  
Fu-Li Zhao ◽  
...  

AbstractSelective transmission or filtering always responds to either frequency or incident angle, so as hardly to maximize signal-to-noise ratio in communication, detection and sensing. Here, we propose compact meta-filters of narrow-frequency sharp-angular transmission peak along with broad omnidirectional reflection sidebands, in all-dielectric cascaded subwavelength meta-gratings. The inherent collective resonance of waveguide-array modes and thin film approximation of meta-grating are employed as the design strategy. A unity transmission peak, locating at the incident angle of 44.4° and the center wavelength of 1550 nm, is demonstrated in a silicon meta-filter consisting of two-layer silicon rectangular meta-grating. These findings provide possibilities in cascaded meta-gratings spectroscopic design and alternative utilities for high signal-to-noise ratio applications in focus-free spatial filtering and anti-noise systems in telecommunications.


Sign in / Sign up

Export Citation Format

Share Document