scholarly journals Short-term Dynamics after Single- and Three-piece Acrylic Intraocular Lens Implantation: A Swept-source Anterior Segment Optical Coherence Tomography Study

2018 ◽  
Vol 8 (1) ◽  
Author(s):  
Tatsuhiko Sato ◽  
Shunsuke Shibata ◽  
Motoaki Yoshida ◽  
Ken Hayashi
2021 ◽  
Vol 8 ◽  
Author(s):  
Zixuan Xiao ◽  
Geng Wang ◽  
Miaoru Zhen ◽  
Zifeng Zhao

Purpose: To investigate the stability of intraocular lens (IOLs) with different haptics by swept-source anterior-segment optical coherence tomography (AS-OCT).Methods: Sixty-eight eyes from 55 patients received the implantation of Rayner 920H (Closed C-loop Group), Zeiss 509M (Plate Group) or Lenstec SOFTEC HD (C-loop Group) IOLs. The tilt and decentration of IOLs were evaluated using AS-OCT at least 1 month postoperatively.Results: Mean decentration and tilt of IOLs were 0.18 ± 0.12 mm (range 0.02 to 0.59 mm) and 5.63 ± 1.65° (range 2.2 to 9.6°) respectively. Decentration was significantly smaller in the plate haptic group (0.12 ± 0.06 mm) as compared to the C-loop group (0.22 ± 0.13 mm, P = 0.02). The tilt of IOL was also significantly smaller in the plate haptic group (4.96 ± 0.89°) as compared to the C-loop group (6.28 ± 1.83°, P = 0.01). There was marginal difference between the Closed C-loop group (5.52 ± 1.74°) and C-loop group (6.28 ± 1.83°, P = 0.07).Conclusions: The Plate-haptic IOLs should have better stability for the decentration and tilt than the C-loop design IOLs.


2021 ◽  
Vol 10 (19) ◽  
pp. 4384
Author(s):  
Tadahiro Mitsukawa ◽  
Yumi Suzuki ◽  
Yosuke Momota ◽  
Shun Suzuki ◽  
Masakazu Yamada

In this paper, we assessed the short-term effects of 0.01% atropine eye drops on anterior segment parameters by performing ocular biometry using a swept-source anterior segment optical coherence tomography system (AS-OCT). We recruited 17 healthy volunteers (10 men and 7 women aged 24–35 years) with no history of eye disease. Participants without accommodative demand demonstrated significant mydriasis 1 h after the atropine instillation (4.58 ± 0.77 to 5.41 ± 0.83 mm). Pupil diameters with a 5 diopter (D) accommodative stimulus at 1 h (4.70 ± 1.13 mm) and 24 h (4.05 ± 1.06 mm) after atropine instillation were significantly larger than those at baseline (3.71 ± 0.84 mm). Barring pupil diameter, no other biometric parameters significantly changed at any point in time after atropine instillation without accommodative demand. However, with an accommodative stimulus, anterior chamber depth (ACD) at 1 h and posterior curvature of the lens at 1 and 24 h were both significantly larger than those before atropine instillation. Using AS-OCT, we detected a slight decrease in the accommodation response of ocular biometric components evoked by 0.01% atropine instillation. Morphologically, our measurements suggested a change in the ACD and horizontal radius of the lens’ posterior surface curvatures due to the subtle reduction of accommodation.


Sign in / Sign up

Export Citation Format

Share Document