scholarly journals Macular vessel density, branching complexity and foveal avascular zone size in normal tension glaucoma

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Kelvin K. W. Cheng ◽  
Beatrice L. Tan ◽  
Lyndsay Brown ◽  
Calum Gray ◽  
Eleonora Bianchi ◽  
...  

AbstractThe aim of this study was to investigate the relationship between glaucoma severity and perifoveal vessel density (pfVD), branching complexity, and foveal avascular zone (FAZ) size in normal tension glaucoma (NTG). 31 patients with NTG washed out of glaucoma medications were subjected to tests including; intraocular pressure measurement; standard automated perimetry; optical coherence tomography (OCT) measurement of macular ganglion cell complex (mGCC), inner macular thickness (IMT) and circumpapillary retinal nerve fibre layer (cpRNFL); and OCT angiography measurement of pfVD, FAZ perimeter and multispectral fractal dimensions (MSFD). Eyes with more severe glaucoma had significantly thinner mGCC and cpRNFL and lower pfVD. MD decreased by 0.4 dB (95% CI 0.1 to 0.6 dB, P = 0.007) for every 1% decrease in pfVD. Lower MSFD was observed in eyes with lower pfVD and in patients with systemic hypertension. Multivariable analysis, accounting for age and OCTA quality, found lower pfVD remained significantly associated with thinner IMT, thinner mGCC and worse MD but not with MSFD. pfVD was reduced in NTG and was diminished in eyes with worse MD. Macular vessel branching complexity was not related to severity of visual field loss but was lower in patients with systemic hypertension.

2017 ◽  
Vol 2017 ◽  
pp. 1-7 ◽  
Author(s):  
Maja Zivkovic ◽  
Volkan Dayanir ◽  
Tolga Kocaturk ◽  
Marko Zlatanovic ◽  
Gordana Zlatanovic ◽  
...  

Aim. To measure diameter of foveal avascular zone (FAZ), FAZ area, and vessel density using Optical Coherence Tomography Angiography (OCT-A) in patients with normal tension glaucoma (NTG) and to establish the possible role of OCT-A in diagnosis and follow-up of patients with NTG. Methods. Twenty-one eyes of 21 patients with NTG and 30 eyes of 30 healthy subjects underwent complete ophthalmic examination as well as OCT-A on ZEISS AngioPlex. 3×3 macula scans were used to measure vertical, horizontal, and maximum diameter of FAZ by two graders. Mean values and interobserver variability were analyzed. Image J was used for analysis of FAZ area and vessel density. Results. Mean vertical diameter (t=5.58, p<0.001), horizontal diameter (t=3.59, p<0.001), maximum diameter (t=5.94, p<0.001), and FAZ area (t=5.76, p<0.001) were statistically significantly enlarged in the NTG group compared to those in the control group. Vessel density (t=-5.80, p<0.001) was statistically significantly decreased in the NTG group compared to that in the control group. Conclusion. OCT-A could have an important role in the future in diagnosis of patients with NTG. In patients with NTG, there is larger FAZ area, while the vessel density is reduced in comparison to the control group.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Kangcheng Liu ◽  
Huizhuo Xu ◽  
Haibo Jiang ◽  
Hua Wang ◽  
Pingbao Wang ◽  
...  

Abstract This study analyzed the optical coherence tomography angiography (OCTA) macular parameters in primary angle-closure glaucoma (PACG) patients after acute primary angle closure (APAC) episodes. Thirty-three patients with 33 APAC eyes and 33 primary angle closure suspect (PACS) eyes and 33 age-matched normal subjects (controls) were enrolled. Macular vessel density (VD) in central, inner, outer and full regions and foveal avascular zone (FAZ) parameters (area, perimeter and circularity index) were compared between APAC, PACS, and control eyes. For resolved APAC eyes, the VD in each macular region was significantly lower than that in control eyes, with less central and inner macular VD than PACS eyes. The central macular VD was significantly lower in PACS eyes than in controls. There was no difference in FAZ area and perimeter between APAC, PACS, and control eyes. FAZ circularity was highest in control eyes, followed by PACS eyes, and lowest in APAC eyes. The AUC, sensitivity and specificity of FAZ circularity were 0.944, 93.9% and 84.8%, respectively, in APAC eyes and 0.881, 84.8% and 81.8%, respectively, in PACS eyes. Therefore, FAZ circularity had the best discrimination capability for detecting both APAC and PACS eyes. Macular assessment with OCTA could provide an accurate early-stage diagnostic tool for PACG.


2012 ◽  
Vol 4 (2) ◽  
pp. 236-241
Author(s):  
S Ganekal

Objective: To compare the macular ganglion cell complex (GCC) with peripapillary retinal fiber layer (RNFL) thickness map in glaucoma suspects and patients. Subjects and methods: Forty participants (20 glaucoma suspects and 20 glaucoma patients) were enrolled. Macular GCC and RNFL thickness maps were performed in both eyes of each participant in the same visit. The sensitivity and specificity of a color code less than 5% (red or yellow) for glaucoma diagnosis were calculated. Standard Automated Perimetry was performed with the Octopus 3.1.1 Dynamic 24-2 program. Statistics: The statistical analysis was performed with the SPSS 10.1 (SPSS Inc. Chicago, IL, EUA). Results were expressed as mean ± standard deviation and a p value of 0.05 or less was considered significant. Results: Provide absolute numbers of these findings with their units of measurement. There was a statistically significant difference in average RNFL thickness (p=0.004), superior RNFL thickness (p=0.006), inferior RNFL thickness (p=0.0005) and average GCC (p=0.03) between the suspects and glaucoma patients. There was no difference in optic disc area (p=0.35) and vertical cup/disc ratio (p=0.234) in both groups. While 38% eyes had an abnormal GCC and 13% had an abnormal RNFL thickness in the glaucoma suspect group, 98% had an abnormal GCC and 90% had an abnormal RNFL thickness in the glaucoma group.Conclusion: The ability to diagnose glaucoma with macular GCC thickness is comparable to that with peripapillary RNFL thickness. Macular GCC thickness measurements may be a good alternative or a complementary measurement to RNFL thickness assessment in the clinical evaluation of glaucoma.DOI: http://dx.doi.org/10.3126/nepjoph.v4i2.6538 Nepal J Ophthalmol 2012; 4 (2): 236-241 


2019 ◽  
Vol 30 (6) ◽  
pp. 1418-1423 ◽  
Author(s):  
Claudio Furino ◽  
Grazia Montrone ◽  
Maria Vittoria Cicinelli ◽  
Stefania Balestra ◽  
Maria Oliva Grassi ◽  
...  

Purpose: To investigate a subset of diabetic patients without diabetic retinopathy with optical coherence tomography angiography, assessing the differences in macular perfusion between diseased eyes and healthy controls. Methods: Monocentric cross-sectional study, including 86 eyes from 43 diabetic patients with no clinical signs of diabetic retinopathy and 78 eyes from 39 controls. Patients underwent 3.0 × 3.0 mm and 4.5 × 4.5 mm swept-source optical coherence tomography angiography. Vessel density (%), foveal avascular zone area (mm2), and avascular density (%) were provided for the superficial capillary plexus and the deep capillary plexus. Results: The foveal avascular zone area at the superficial capillary plexus was larger in the study group compared to controls, irrespective of the area of the slab considered. A meaningful difference was found in the vessel density at the deep capillary plexus of the 3.0 × 3.0 mm slab (p = 0.03). Almost all the variables considered in the study showed a significant within-subject effect. Age significantly correlated with vessel density of superficial capillary plexus on 4.5 × 4.5 mm in both control and diabetic eyes. Conclusion: Diabetic patients with subclinical diabetic retinopathy feature a larger foveal avascular zone at the superficial capillary plexus compared with controls, as well as relative reduction of the vessel density at the deep capillary plexus. These findings might serve as the basis for screening between normal and diabetic subjects.


Author(s):  
Barbara Cvenkel ◽  
Maja Sustar ◽  
Darko Perovšek

Abstract Purpose To investigate the value of pattern electroretinography (PERG) and photopic negative response (PhNR) in monitoring glaucoma compared to standard clinical tests (standard automated perimetry (SAP) and clinical optic disc assessment) and structural measurements using spectral-domain OCT. Methods A prospective study included 32 subjects (32 eyes) with ocular hypertension, suspect or early glaucoma monitored for progression with clinical examination, SAP, PERG, PhNR and OCT for at least 4 years. Progression was defined clinically by the documented change of the optic disc and/or significant visual field progression (EyeSuite™ trend analysis). One eye per patient was included in the analysis. Results During the follow-up, 13 eyes (40.6%) showed progression, whereas 19 remained stable. In the progressing group, all parameters showed significant worsening over time, except for the PhNR, whereas in the stable group only the OCT parameters showed a significant decrease at the last visit. The trend of change over time using linear regression was steepest for the OCT parameters. At baseline, only the ganglion cell complex (GCC) and peripapillary retinal nerve fibre (pRNFL) thicknesses significantly discriminated between the stable and progressing eyes with the area under the ROC curve of 0.72 and 0.71, respectively. The inter-session variability for the first two visits in the stable group was lower for OCT (% limits of agreement within ± 17.4% of the mean for pRNFL and ± 3.6% for the GCC thicknesses) than for ERG measures (within ± 35.9% of the mean for PERG N95 and ± 59.9% for PhNR). The coefficient of variation for repeated measurements in the stable group was 11.9% for PERG N95 and 23.6% for the PhNR, while it was considerably lower for all OCT measures (5.6% for pRNFL and 1.7% for GCC thicknesses). Conclusions Although PERG and PhNR are sensitive for early detection of glaucomatous damage, they have limited usefulness in monitoring glaucoma progression in clinical practice, mainly due to high inter-session variability. On the contrary, OCT measures show low inter-session variability and might have a predicting value for early discrimination of progressing cases.


2022 ◽  
pp. 112067212110734
Author(s):  
Susan M. O'Shea ◽  
Veronica M. O’Dwyer ◽  
Grainne Scanlon

Purpose To establish normative data on the size, shape and vascular profile of the foveal avascular zone (FAZ) in a young, healthy, Irish population, using the Cirrus 5000 HD-OCT. Certain diseases may alter FAZ appearance. Normative databases provide normal baseline values for comparison, thus improving diagnostic ability. Methods One hundred and fifty-four subjects aged 18–35 years old were recruited. Superficial FAZ area, diameter, circularity, ganglion cell layer, central macular thickness (CMT), vascular perfusion and density were measured using the Cirrus 5000. Axial length was measured with the IOL Master and blood pressure was measured using the Omron sphygmomanometer. Results Mean FAZ area was 0.22 ± 0.07 mm2, mean CMT was 263.08 ± 18.73μm. Both were larger in females than males (p = 0.022, p = 0.000). Mean vessel density and perfusion central were 14.11 ± 2.77 mm/mm2 and 24.70 ± 4.96% respectively. Both were lower in females (p = 0.010, p = 0.019). Vessel density and perfusion inner correlated positively with minimum ganglion cell layer plus inner plexiform layer (GCL + IPL) thickness (p = 0.001, p = 0.019). CMT correlated positively with vessel density and perfusion central (p = 0.000 for both) and negatively with FAZ area (p = 0.000). Conclusions This study provides normative data for FAZ appearance and vascularity for the first time in a young, healthy, Irish population, using the Cirrus 5000 HD-OCT. Establishing machine and population specific normative data, particularly in relation to vessel density and perfusion is paramount to the early identification of ocular disease using Optical Coherence Tomography Angiography.


Sign in / Sign up

Export Citation Format

Share Document