scholarly journals Pulse arrival time as a surrogate of blood pressure

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Eoin Finnegan ◽  
Shaun Davidson ◽  
Mirae Harford ◽  
João Jorge ◽  
Peter Watkinson ◽  
...  

AbstractVarious models have been proposed for the estimation of blood pressure (BP) from pulse transit time (PTT). PTT is defined as the time delay of the pressure wave, produced by left ventricular contraction, measured between a proximal and a distal site along the arterial tree. Most researchers, when they measure the time difference between the peak of the R-wave in the electrocardiogram signal (corresponding to left ventricular depolarisation) and a fiducial point in the photoplethysmogram waveform (as measured by a pulse oximeter attached to the fingertip), describe this erroneously as the PTT. In fact, this is the pulse arrival time (PAT), which includes not only PTT, but also the time delay between the electrical depolarisation of the heart’s left ventricle and the opening of the aortic valve, known as pre-ejection period (PEP). PEP has been suggested to present a significant limitation to BP estimation using PAT. This work investigates the impact of PEP on PAT, leading to a discussion on the best models for BP estimation using PAT or PTT. We conducted a clinical study involving 30 healthy volunteers (53.3% female, 30.9 ± 9.35 years old, with a body mass index of 22.7 ± 3.2 kg/m$$^{2}$$ 2 ). Each session lasted on average 27.9 ± 0.6 min and BP was varied by an infusion of phenylephrine (a medication that causes venous and arterial vasoconstriction). We introduced new processing steps for the analysis of PAT and PEP signals. Various population-based models (Poon, Gesche and Fung) and a posteriori models (inverse linear, inverse squared and logarithm) for estimation of BP from PTT or PAT were evaluated. Across the cohort, PEP was found to increase by 5.5 ms ± 4.5 ms from its baseline value. Variations in PTT were significantly larger in amplitude, − 16.8 ms ± 7.5 ms. We suggest, therefore, that for infusions of phenylephrine, the contribution of PEP on PAT can be neglected. All population-based models produced large BP estimation errors, suggesting that they are insufficient for modelling the complex pathways relating changes in PTT or PAT to changes in BP. Although PAT is inversely correlated with systolic blood pressure (SBP), the gradient of this relationship varies significantly from individual to individual, from − 2946 to − 470.64 mmHg/s in our dataset. For the a posteriori inverse squared model, the root mean squared errors (RMSE) for systolic and diastolic blood pressure (DBP) estimation from PAT were 5.49 mmHg and 3.82 mmHg, respectively. The RMSEs for SBP and DBP estimation by PTT were 4.51 mmHg and 3.53 mmHg, respectively. These models take into account individual calibration curves required for accurate blood pressure estimation. The best performing population-based model (Poon) reported error values around double that of the a posteriori inverse squared model, and so the use of population-based models is not justified.

2016 ◽  
Vol 6 (1) ◽  
Author(s):  
Stephanie L.-O. Martin ◽  
Andrew M. Carek ◽  
Chang-Sei Kim ◽  
Hazar Ashouri ◽  
Omer T. Inan ◽  
...  

Abstract Pulse transit time (PTT) is being widely pursued for cuff-less blood pressure (BP) monitoring. Most efforts have employed the time delay between ECG and finger photoplethysmography (PPG) waveforms as a convenient surrogate of PTT. However, these conventional pulse arrival time (PAT) measurements include the pre-ejection period (PEP) and the time delay through small, muscular arteries and may thus be an unreliable marker of BP. We assessed a bathroom weighing scale-like system for convenient measurement of ballistocardiography and foot PPG waveforms – and thus PTT through larger, more elastic arteries – in terms of its ability to improve tracking of BP in individual subjects. We measured “scale PTT”, conventional PAT, and cuff BP in humans during interventions that increased BP but changed PEP and smooth muscle contraction differently. Scale PTT tracked the diastolic BP changes well, with correlation coefficient of −0.80 ± 0.02 (mean ± SE) and root-mean-squared-error of 7.6 ± 0.5 mmHg after a best-case calibration. Conventional PAT was significantly inferior in tracking these changes, with correlation coefficient of −0.60 ± 0.04 and root-mean-squared-error of 14.6 ± 1.5 mmHg (p < 0.05). Scale PTT also tracked the systolic BP changes better than conventional PAT but not to an acceptable level. With further development, scale PTT may permit reliable, convenient measurement of BP.


2019 ◽  
Vol 127 (4) ◽  
pp. 1050-1057
Author(s):  
Katelyn N. Wood ◽  
Danielle K. Greaves ◽  
Richard L. Hughson

We tested the hypothesis that acute changes in arterial blood pressure (BP) when astronauts moved between supine and standing posture before and after spaceflight can be tracked by beat-to-beat changes in pulse arrival time (PAT). Nine male crewmembers (45 ± 7 yr of age; mean mission length: 165 ± 13 days) participated in a standardized supine-to-sit-to-stand test (5 min-30 s-3 min) before flight and 1 day following return to Earth with continuous monitoring of ECG and finger arterial BP. PAT was determined from the R-wave of the ECG to the foot of the BP waveform. On average, modest cardiovascular deconditioning was detected by ~10 beats/min increase in heart rate in supine and standing posture after spaceflight ( P < 0.05). When looking across the full data collection period, the r2 values between inverse of PAT (1/PAT) and systolic (SBP) and diastolic BP (DBP) varied considerably between individuals (SBP preflight 0.142 ± 0.186, postflight 0.262 ± 0.243). Individual variability was consistent during periods of transition (SBP preflight 0.284 ± 0.324, postflight 0.297 ± 0.269); however, when SBP dropped >20 mmHg, r2 was significant in 5 of 5 preflight tests and 5 of 7 postflight tests. The standard error of the estimate based on a simple linear model during both pre- and postflight testing was 9–11 mmHg for SBP and 6–7 mmHg for DBP. Overall, the results support the hypothesis that PAT tracked dynamic changes in BP. PAT as a noninvasive, nonintrusive surrogate for changes in BP could be developed as an indicator of risk for syncope on return from spaceflight or other Earth-based applications. NEW & NOTEWORTHY Astronauts returning to Earth’s gravity are at increased risk of low blood pressure on standing. Arterial pulse arrival time tracked the decrease in arterial blood pressure on moving from supine to upright posture. Nonintrusive technology providing indicators sensitive to acute changes in blood pressure could act as an early warning system to identify risk for hypotension that place astronauts, or people on Earth, at risk of impaired cognitive performance, fainting, and falls.