CHAPTER 13. Bacterial Adhesion and Interaction with Biomaterial Surfaces

Author(s):  
Li-Chong Xu ◽  
Christopher A. Siedlecki
1993 ◽  
Vol 16 (11) ◽  
pp. 755-764 ◽  
Author(s):  
A.G. Gristina ◽  
G. Giridhar ◽  
B.L Gabriel ◽  
P.T. Naylor ◽  
Q.N. Myrvik

Biomaterials are being used with increasing frequency for tissue substitution. Complex devices such as total joint replacement and the total artificial heart represent combinations of polymers and metal alloys for system and organ replacement. The major barrier to the extended use of these devices is bacterial adhesion to biomaterials, which causes biomaterial-centered infection, and the lack of successful tissue integration or compatibility with biomaterial surfaces. Adhesion-mediated infections are extremely resistant to antibiotics and host defenses and frequently persist until the biomaterial or foreign body is removed. The pathogenesis of adhesive infections is related, in part, to preferential colonization of “inert” substrata whose surfaces are not integrated with healthy tissues composed of living cells and intact extracellular polymers. Tissue integration is an interesting parallel to microbial adhesion and is a desired phenomenon for the biocompatibility of certain implants and biomaterials. Tissue integration requires a form of eukaryocytic adhesion or compatibility with possible chemical integration to an implant surface. Many of the fundamental principles of interfacial science apply to both microbial adhesion and to tissue integration and are general to and independent of the substratum materials involved. Interactions of biomaterials with bacteria and tissue cells are directed not only by specific receptors and outer membrane molecules on the cell surface, but also by the atomic geometry and electronic state of the biomaterial surface. An understanding of these mechanisms is important to all fields of medicine and is derived from and relevant to studies in microbiology, biochemistry, and physics. Modifications of biomaterial surfaces at an atomic level will allow the programming of cell-to-substratum events, thereby diminishing infection by enhancing tissue compatibility or integration, or by directly inhibiting bacterial adhesion.


Author(s):  
T.F. Moriarty ◽  
A.H.C. Poulsson ◽  
E.T.J. Rochford ◽  
R.G. Richards

2007 ◽  
Vol 73 (8) ◽  
pp. 2653-2660 ◽  
Author(s):  
Rainer Müller ◽  
Gerhard Gröger ◽  
Karl-Anton Hiller ◽  
Gottfried Schmalz ◽  
Stefan Ruhl

ABSTRACT For quantification of bacterial adherence to biomaterial surfaces or to other surfaces prone to biofouling, there is a need for methods that allow a comparative analysis of small material specimens. A new method for quantification of surface-attached biotinylated bacteria was established by in situ detection with fluorescence-labeled avidin-D. This method was evaluated utilizing a silicon wafer model system to monitor the influences of surface wettability and roughness on bacterial adhesion. Furthermore, the effects of protein preadsorption from serum, saliva, human serum albumin, and fibronectin were investigated. Streptococcus gordonii, Streptococcus mitis, and Staphylococcus aureus were chosen as model organisms because of their differing adhesion properties and their clinical relevance. To verify the results obtained by this new technique, scanning electron microscopy and agar replica plating were employed. Oxidized and poly(ethylene glycol)-modified silicon wafers were found to be more resistant to bacterial adhesion than wafers coated with hydrocarbon and fluorocarbon moieties. Roughening of the chemically modified surfaces resulted in an overall increase in bacterial attachment. Preadsorption of proteins affected bacterial adherence but did not fully abolish the influence of the original surface chemistry. However, in certain instances, mostly with saliva or serum, masking of the underlying surface chemistry became evident. The new bacterial overlay method allowed a reliable quantification of surface-attached bacteria and could hence be employed for measuring bacterial adherence on material specimens in a variety of applications.


2009 ◽  
Vol 117 (4) ◽  
pp. 419-426 ◽  
Author(s):  
Li Mei ◽  
Henk J. Busscher ◽  
Henny C. van der Mei ◽  
Yangxi Chen ◽  
Joop de Vries ◽  
...  

Author(s):  
T.F. Moriarty ◽  
A.H.C. Poulsson ◽  
E.T.J. Rochford ◽  
R.G. Richards

2014 ◽  
Vol 2014 ◽  
pp. 1-6 ◽  
Author(s):  
Monica Thukkaram ◽  
Soundarya Sitaram ◽  
Sathish kumar Kannaiyan ◽  
Guruprakash Subbiahdoss

Biofilm growth on the implant surface is the number one cause of the failure of the implants. Biofilms on implant surfaces are hard to eliminate by antibiotics due to the protection offered by the exopolymeric substances that embed the organisms in a matrix, impenetrable for most antibiotics and immune cells. Application of metals in nanoscale is considered to resolve biofilm formation. Here we studied the effect of iron-oxide nanoparticles over biofilm formation on different biomaterial surfaces and pluronic coated surfaces. Bacterial adhesion for 30 min showed significant reduction in bacterial adhesion on pluronic coated surfaces compared to other surfaces. Subsequently, bacteria were allowed to grow for 24 h in the presence of different concentrations of iron-oxide nanoparticles. A significant reduction in biofilm growth was observed in the presence of the highest concentration of iron-oxide nanoparticles on pluronic coated surfaces compared to other surfaces. Therefore, combination of polymer brush coating and iron-oxide nanoparticles could show a significant reduction in biofilm formation.


Sign in / Sign up

Export Citation Format

Share Document