One-step electrodeposition of a nickel cobalt sulfide nanosheet film as a highly sensitive nonenzymatic glucose sensor

2016 ◽  
Vol 4 (47) ◽  
pp. 7540-7544 ◽  
Author(s):  
Xiaoqin Cao ◽  
Kunyang Wang ◽  
Gu Du ◽  
Abdullah M. Asiri ◽  
Yongjun Ma ◽  
...  

An electrodeposited nickel cobalt sulfide nanosheet film acts as a nonenzymatic glucose sensor with wide linear response range of 0.001–3 mM, low detection limit of 0.12 μM, high sensitivity of 3291.5 μA mM−1 cm−2, as well as good selectivity and long-term stability.

2020 ◽  
Vol 20 (12) ◽  
pp. 7333-7341
Author(s):  
Feng Chen ◽  
Jing-Hao Li ◽  
Yu-Chen Chi ◽  
Zhen-Hua Dan ◽  
Feng-Xiang Qin

A unique nanostructured electrocatalyst based on Palladium (Pd) nanosponge architecture is synthesized by one-step dealloying of the amorphous alloy precursor with low Pd concentration. The sponge-like nanostructure with hollow interiors enables sufficient contact between reactants andboth the interior and exterior surfaces. The results of cyclic voltammetry reveal that the as-prepared Pd nanosponge exhibits high sensitivity of 32 μA mM−1 cm−2 in a wide linear range (1–18 mM), and long-term stability toward glucose electro-oxidation. The Pd nanosponge also manifests detection limit as low as 2.0 μM (S/N = 3) and high selectivity for glucose sensing. The enhanced catalytic activity of the Pd nanosponge is attributed to the bimetallic synergistic effect and the large active surface area of the high-uniformity porous structure. The facile synthesis of the cost-effective Pd nanosponge with superior electrocatalytic performance makes it hold great potentials for biosensor and other catalysis applications.


2016 ◽  
Vol 163 (5) ◽  
pp. D175-D178 ◽  
Author(s):  
Vu Hong Vinh Quy ◽  
Bong-Ki Min ◽  
Jae-Hong Kim ◽  
Hyunsoo Kim ◽  
John Anthuvan Rajesh ◽  
...  

2014 ◽  
Vol 2014 ◽  
pp. 1-5 ◽  
Author(s):  
Xiaoxu Ji ◽  
Aihua Wang ◽  
Qinghuai Zhao

Copper oxide (CuO) films directly grown on Ti substrate have been successfully prepared via a hydrothermal method and used to construct an amperometric nonenzymatic glucose sensor. XRD and SEM were used to characterize the samples. The electrochemical performances of the electrode for detection of glucose were investigated by cyclic voltammetry and chronoamperometry. The CuO films based glucose sensors exhibit enhanced electrocatalytic properties which show very high sensitivity (726.9 μA mM−1 cm−2), low detection limit (2 μM), and fast response (2 s). In addition, reproducibility and long-term stability have been observed. Low cost, convenience, and biocompatibility make the CuO films directly grown on Ti substrate electrodes a promising platform for amperometric nonenzymatic glucose sensor.


2018 ◽  
Vol 259 ◽  
pp. 617-625 ◽  
Author(s):  
Shusheng Xu ◽  
Chen Su ◽  
Tao Wang ◽  
Yujie Ma ◽  
Jun Hu ◽  
...  

2017 ◽  
Vol 46 (30) ◽  
pp. 9918-9924 ◽  
Author(s):  
Yinlin Tong ◽  
Jiaying Xu ◽  
Hong Jiang ◽  
Feng Gao ◽  
Qingyi Lu

Novel core–shell Cu@polymer nanocomposites were synthesized through a one-step self-activated route and developed as nonenzymatic glucose sensor.


2020 ◽  
Vol 10 (23) ◽  
pp. 8419
Author(s):  
Adriana Remes ◽  
Florica Manea ◽  
Sorina Motoc (m. Ilies) ◽  
Anamaria Baciu ◽  
Elisabeta I. Szerb ◽  
...  

A novel electrochemical glucose sensor was developed, based on a multiwall carbon nanotubes (MWCNTs)-copper-1,3,5-benzenetricarboxylic acid (CuBTC)-epoxy composite electrode, named MWCNT-CuBTC. The electrode nanocomposite was prepared by a two-roll mill procedure and characterized morphostructurally by scanning electron microscopy (SEM). The CuBTC formed defined crystals with a wide size distribution, which were well dispersed and embedded in the MWCNTs. Its electrical conductivity was determined by four-point probe contact (DC) conductivity measurements. The electroactive surface area, determined using cyclic voltammetry (CV), was found to be 6.9 times higher than the geometrical one. The results of the electrochemical measurements using CV, linear sweep voltammetry (LSV), differential pulse voltammetry (DPV), chronoamperometry (CA) and multiple pulse amperometry (MPA) showed that the MWCNT-CuBTC composite electrode displayed high electrocatalytic activity toward the oxidation of glucose and, as a consequence, very high sensitivity. The best sensitivity of 14,949 µAmM−1cm−1 was reached using MPA at the potential value of 0.6 V/SCE, which was much higher in comparison with other copper-based electrodes reported in the literature. The good analytical performance, low cost and simple preparation method make this novel electrode material promising for the development of an effective glucose sensor.


NANO ◽  
2019 ◽  
Vol 14 (04) ◽  
pp. 1950045
Author(s):  
Fang Sun ◽  
Lehong Xing ◽  
Xihui Yang ◽  
Hailiang Huang ◽  
Lina Ning

In this study, CuO films with hollow cubic cages were prepared by a facile two-step procedure consisting of electrodeposition synthesis and subsequent direct calcination. First, Cu2O nanocubes were fabricated on ITO substrate through a simple electrodeposition procedure. Then, Cu2O nanocubes were converted to CuO hollow cubic cages without obvious morphological change through direct calcination. The obtained CuO cubic cages serving as active materials illustrated a favorable performance for nonenzymatic glucose sensing with high sensitivity of [Formula: see text]A[Formula: see text]mM[Formula: see text][Formula: see text]cm[Formula: see text] at a low applied potential of 0.50[Formula: see text]V, fast-response time (less than 3[Formula: see text]s), low detection limit of 1.0[Formula: see text][Formula: see text]M and wide linear range up from 2.0[Formula: see text][Formula: see text]M to 1.0[Formula: see text]mM ([Formula: see text]). Moreover, the good selectivity of the CuO cubic cages-based nonenzymatic glucose sensor against electroactive compounds such as ascorbic acid, uric acid and dopamine were also demonstrated. These good features indicate that the as-prepared CuO cubic cages can be used as promising electrode materials, which have a great potential in the development of sensitive and selective nonenzymatic glucose sensors.


2018 ◽  
Vol 42 (14) ◽  
pp. 11944-11953 ◽  
Author(s):  
Xinping Zeng ◽  
Yazhou Zhang ◽  
Xiling Du ◽  
Yanfei Li ◽  
Wenwei Tang

The PTFE/GOx/AuNPs/PANI/MWCNTs/GCE glucose sensor possesses wide linear range, low detection limit, high sensitivity, which can measure the glucose in human serum and holds application potential.


Sign in / Sign up

Export Citation Format

Share Document