scholarly journals Effects of a low-strength magnetic field on the characteristics of activated sludge for membrane fouling mitigation

RSC Advances ◽  
2019 ◽  
Vol 9 (16) ◽  
pp. 9180-9186 ◽  
Author(s):  
Ren Zhijun ◽  
Wang Pengfei ◽  
Tian Jiayu ◽  
Zhang Zhiliu

This study aims to investigate the performance of a low-strength magnetic field in membrane bioreactors (MBRs) for membrane fouling mitigation and its effects on sludge characteristics and microbial community.

Membranes ◽  
2020 ◽  
Vol 10 (10) ◽  
pp. 282
Author(s):  
Huining Zhang ◽  
Xin Yuan ◽  
Hanqing Wang ◽  
Shuoqi Ma ◽  
Bixiao Ji

The performance of pollutant removals, tetracycline (TC) and norfloxacin (NOR) removals, membrane fouling mitigation and the microbial community of three Anoxic/Oxic membrane bioreactors (AO-MBRs), including a moving bed biofilm MBR (MBRa), a fixed biofilm MBR (MBRb) and an AO-MBR (MBRc) for control, were compared in treating antibiotic-containing synthetic mariculture wastewater. The results showed that MBRb had the best effect on antibiotic removal and membrane fouling mitigation compared to the other two bioreactors. The maximum removal rate of TC reached 91.65% and the maximum removal rate of NOR reached 45.46% in MBRb. The addition of antibiotics had little effect on the removal of chemical oxygen demand (COD) and ammonia nitrogen (NH4+-N)—both maintained more than 90% removal rate during the entire operation. High-throughput sequencing demonstrated that TC and NOR resulted in a significant decrease in the microbial diversity and the microbial richness MBRs. Flavobacteriia, Firmicutes and Azoarcus, regarded as drug-resistant bacteria, might play a crucial part in the removal of antibiotics. In addition, the dynamics of microbial community had a great change, which included the accumulation of resistant microorganisms and the gradual reduction or disappearance of other microorganisms under antibiotic pressure. The research provides an insight into the antibiotic-containing mariculture wastewater treatment and has certain reference value.


Membranes ◽  
2020 ◽  
Vol 10 (9) ◽  
pp. 231
Author(s):  
Yi Ding ◽  
Zhansheng Guo ◽  
Zhenlin Liang ◽  
Xuguang Hou ◽  
Zhipeng Li ◽  
...  

In this study, the characteristics of activated sludge flocs were investigated and their effects on the evolution of membrane fouling were considered in the anaerobic membrane bioreactors (AnMBR), which were operated at 25 and 35 °C for municipal wastewater treatment. It was found that the membrane fouling rate of the AnMBR at 25 °C was more severe than that at 35 °C. The membrane fouling trends were not consistent with the change in the concentration of soluble microbial product (SMP). The larger amount of SMP in the AnMBR at 35 °C did not induce more severe membrane fouling than that in the AnMBR at 25 °C. However, the polysaccharide and protein concentration of extracellular polymeric substance (EPS) was higher in the AnMBR at 25 °C in comparison with that in the AnMBR at 35 °C, and the protein/polysaccharide ratio of the EPS in the AnMBR at 25 °C was higher in contrast to that in the AnMBR at 35 °C. Meanwhile, the fouling tendencies measured for the AnMBRs could be related to the characteristics of loosely bound EPS and tightly bound EPS. The analysis of the activated sludge flocs characteristics indicated that a smaller sludge particle size and more fine flocs were observed at the AnMBR with 25 °C. Therefore, the membrane fouling potential in the AnMBR could be explained by the characteristics of activated sludge flocs.


2008 ◽  
Vol 58 (10) ◽  
pp. 1925-1931 ◽  
Author(s):  
Z. Huang ◽  
S. L. Ong ◽  
H. Y. Ng

Two 6-L submerged anaerobic membrane bioreactors (SAMBR) with SRT of 30 and 60 d (denoted as R30 and R60, respectively) were set up and operated for five months, with a mixture of glucose as substrate. Feasibility of SAMBR was studied for treatment of low-strength wastewater. First two months were identified as acclimation stage. A COD removal efficiency was achieved stably at around 99% and biogas productions were maintained at 0.023 and 0.028 L CH4/gMLVSS∙d for R30 and R60, respectively. Even though R60 contained higher MLVSS concentration, no significant difference of treatment performances between both reactors was found due to the low organic loading rate and high purification function of membrane. In the investigation of membrane fouling, less irreversible fouling was observed for R30 compared to R60. High non-flocculent concentration of R60 would be responsible for membrane internal pore blocking and deteriorated effluent quality.


2006 ◽  
Vol 51 (1) ◽  
pp. 95-103 ◽  
Author(s):  
Fangang Meng ◽  
Hanmin Zhang ◽  
Fenglin Yang ◽  
Shoutong Zhang ◽  
Yansong Li ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document