scholarly journals A novel, fast, high sensitivity biosensor for supporting therapeutic decisions and onset actions for chest pain cases

RSC Advances ◽  
2019 ◽  
Vol 9 (35) ◽  
pp. 20463-20471 ◽  
Author(s):  
Sheta M. Sheta ◽  
Said M. El-Sheikh ◽  
Mokhles M. Abd-Elzaher ◽  
Mosaad L. Ghanem ◽  
Salem R. Salem

A novel organic nano linker (NL) and manganese metal–organic framework (Mn–MOF) were synthesized and fully characterized. A promising cardiac troponin-I potentiometric biosensor based on Mn–MOF could be used for early myocardial infarction diagnosis.

2019 ◽  
Vol 65 (11) ◽  
pp. 1426-1436 ◽  
Author(s):  
Jasper Boeddinghaus ◽  
Raphael Twerenbold ◽  
Thomas Nestelberger ◽  
Luca Koechlin ◽  
Desiree Wussler ◽  
...  

Abstract BACKGROUND We aimed to validate the clinical performance of the high-sensitivity cardiac troponin I [VITROS® Immunodiagnostic Products hs Troponin I (hs-cTnI-VITROS)] assay. METHODS We enrolled patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction (AMI). Final diagnoses were centrally adjudicated by 2 independent cardiologists considering all clinical information, including cardiac imaging: first, using serial hs-cTnT-Elecsys (primary analysis) and, second, using hs-cTnI-Architect (secondary analysis) measurements in addition to the clinically used (hs)-cTn. hs-cTnI-VITROS was measured at presentation and at 1 h in a blinded fashion. The primary objective was direct comparison of diagnostic accuracy as quantified by the area under the ROC curve (AUC) of hs-cTnI-VITROS vs hs-cTnT-Elecsys and hs-cTnI-Architect, and in a subgroup also hs-cTnI-Centaur and hs-cTnI-Access. Secondary objectives included the derivation and validation of an hs-cTnI-VITROS-0/1-h algorithm. RESULTS AMI was the adjudicated final diagnosis in 158 of 1231 (13%) patients. At presentation, the AUC for hs-cTnI-VITROS was 0.95 (95% CI, 0.93–0.96); for hs-cTnT-Elecsys, 0.94 (95% CI, 0.92–0.95); and for hs-cTnI-Architect, 0.92 (95% CI, 0.90–0.94). AUCs for hs-cTnI-Centaur and hs-cTnI-Access were 0.95 (95% CI, 0.94–0.97). Applying the derived hs-cTnI-VITROS-0/1-h algorithm (derivation cohort n = 519) to the validation cohort (n = 520), 53% of patients were ruled out [sensitivity, 100% (95% CI, 94.1–100)] and 14% of patients were ruled in [specificity, 95.6% (95% CI, 93.4–97.2)]. Patients ruled out by the 0/1-h algorithm had a survival rate of 99.8% at 30 days. Findings were confirmed in the secondary analyses using the adjudication including serial measurements of hs-cTnI-Architect. CONCLUSIONS The hs-cTnI-VITROS assay has at least comparable diagnostic accuracy with the currently best validated hs-cTnT and hs-cTnI assays. ClinicalTrials.gov Identifier NCT00470587.


2018 ◽  
Vol 39 (suppl_1) ◽  
Author(s):  
M Rubini Gimenez ◽  
P Badertscher ◽  
R Twerenbold ◽  
J Boeddinghaus ◽  
T Nestelberger ◽  
...  

2020 ◽  
Vol 75 (10) ◽  
pp. 1111-1124 ◽  
Author(s):  
Jasper Boeddinghaus ◽  
Thomas Nestelberger ◽  
Luca Koechlin ◽  
Desiree Wussler ◽  
Pedro Lopez-Ayala ◽  
...  