A broadband optical pH sensor using upconversion luminescence

Author(s):  
Suresh K ◽  
Aseefhali Bankapur ◽  
C. Santhosh ◽  
Harishkumar Madhyastha ◽  
K Sakai ◽  
...  

Determination of the pH value of a medium without the usage of less photostable and toxic dye molecules or the dye incorporated particles still remains a challenging task. Here, we...

Coatings ◽  
2022 ◽  
Vol 12 (1) ◽  
pp. 88
Author(s):  
Eka Safitri ◽  
Zatul Omaira ◽  
Nazaruddin Nazaruddin ◽  
Irfan Mustafa ◽  
Sitti Saleha ◽  
...  

Considering the significance of its demand around the world, the accurate determination of fish freshness with a simple and rapid procedure has become an interesting issue for the fishing industry. Hence, we aimed to fabricate a new optical pH sensor based on a polyelectrolyte (PEC) membrane of pectin–chitosan and the active material chromoionophore ETH 5294. A trial-and-error investigation of the polymer compositions revealed that the optimum ratio of pectin to chitosan was 3:7. With an optimum wavelength region (λ) at 610 nm, the constructed sensor was capable of stable responses after 5 min exposure to phosphate-buffered solution. Furthermore, the obtained sensor achieved optimum sensitivity when the PBS concentration was 0.1 M, while the relative standard deviation values ranged from 2.07 to 2.34%, suggesting good reproducibility. Further investigation revealed that the sensor experienced decreased absorbance of 16.67–18.68% after 25 days of storage. Employing the optimum conditions stated previously, the sensor was tested to monitor fish freshness in samples that were stored at 4 °C and ambient temperature. The results suggested that the newly fabricated optical sensor could measure pH changes on fish skin after 25 h storage at room temperature (pH 6.37, 8.91 and 11.02, respectively) and 4 °C (pH 6.8, 7.31 and 7.92, respectively).


F1000Research ◽  
2021 ◽  
Vol 10 ◽  
pp. 422
Author(s):  
Nazaruddin Nazaruddin ◽  
Nurul Afifah ◽  
Muhammad Bahi ◽  
Susilawati Susilawati ◽  
Nor Diyana Md. Sani ◽  
...  

A simple optical pH sensor using the active compound anthocyanin (ACN), derived Ruellia tuberosa L. flower immobilized in a pectin membrane matrix, was been fabricated and employed to monitor the freshness of tilapia fish at room temperature and 4oC storage. The optimum pectin weight and ACN concentrations were 0.1% and 0.025 mg/L. The sensor showed good sensitivity at 0.03 M phosphate buffer solution. The sensor’s reproducibility was evaluated using 10 replicate sensors where a standard deviation of 0.045 or relative standard deviation of 9.15 was achieved. The sensor displayed an excellent response after 10 minutes of exposure, possessing a response stability for 10 consecutive days. The decrease in pH value of the Tilapia fish from 7.3 to 5 was observed in a 48 hour test, which can be used as the parameter when monitoring fish freshness.


Polymers ◽  
2019 ◽  
Vol 11 (4) ◽  
pp. 715 ◽  
Author(s):  
Tomasz Czaja ◽  
Kamil Wójcik ◽  
Maria Grzeszczuk ◽  
Roman Szostak

An easy-to-prepare pH sensor based on electrochemically obtained polypyrrole doped with methyl orange ions is described. It enables the determination of a pH value in the 3–13 range for volumes below 1 µL. In a wide pH range, resonance and pre-resonance methyl orange Raman spectra, excited with the 514.5 nm line of an Ar+ laser, changed noticeably in function of H+ concentration. Two types of measurements were performed. In the first case, Raman spectra of the analyzed solutions were collected for samples placed on the sensor surface using a confocal microscope equipped with a 10x objective. Next, measurements were conducted for the same samples without the sensor. On the basis of these spectra, partial least-squares models were elaborated and validated. Relative standard errors of prediction for calibration, validation, and test samples were found to be in the 3.7%–3.9% range. An analogous model build using spectra registered without the sensor was characterized by slightly worse parameters.


F1000Research ◽  
2021 ◽  
Vol 10 ◽  
pp. 422
Author(s):  
Nazaruddin Nazaruddin ◽  
Nurul Afifah ◽  
Muhammad Bahi ◽  
Susilawati Susilawati ◽  
Nor Diyana Md. Sani ◽  
...  

A simple optical pH sensor using the active compound anthocyanin (ACN), derived Ruellia tuberosa L. flower immobilized in a pectin membrane matrix, was been fabricated and employed to monitor the freshness of tilapia fish at room temperature and 4oC storage. The quantitative pH values were measured based on the UV-Vis spectroscopy absorbance. The optimum pectin weight and ACN concentrations were 0.1% and 0.025 mg/L. The sensor showed good sensitivity at 0.03 M phosphate buffer solution. The sensor’s reproducibility was evaluated using 10 replicate sensors where a standard deviation of 0.045 or relative standard deviation of 9.15 was achieved. The sensor displayed an excellent response after 10 minutes of exposure, possessing a response stability for 10 consecutive days. The decrease in pH value of the Tilapia fish from 7.3 to 5 was observed in a 48 hour test, which can be used as the parameter when monitoring fish freshness. Overall, this reported optical pH sensor has a novelty as it could be used to monitor the rigor mortis phase of fish meat, which is useful in food industry.


RSC Advances ◽  
2014 ◽  
Vol 4 (99) ◽  
pp. 55897-55899 ◽  
Author(s):  
Song Wang ◽  
Jing Feng ◽  
Shuyan Song ◽  
Hongjie Zhang

Sign in / Sign up

Export Citation Format

Share Document