Factors Associated With Hearing Aid Wear Time in a Subset of U.S. Military Veterans: Tinnitus, the Presence of One or More Neurologic Conditions, and Unaided Speech Intelligibility Index

2021 ◽  
pp. 1-6
Author(s):  
Nicholas P. Giuliani

Purpose A retrospective analysis was conducted to explore how tinnitus, one or more neurologic conditions, unaided speech intelligibility index, and other comorbidities impact the average number of hours hearing aids are worn each day by U.S. Military Veterans. Method Medical records and a hearing aid database were queried to obtain information regarding active medical problems and average daily hearing aid wear time. Multiple linear regression was used to explore these relationships for 215 male Veterans whose records were available from 2009 to 2020. To be analyzed, Veterans must have possessed their hearing aid(s) for at least 3 consecutive months. Results An active problem of subjective tinnitus was associated with increased hearing aid wear time (positive association) and one or more active neurologic conditions were associated with decreased hearing aid wear time (negative association). A high unaided speech intelligibility index (greater access to speech sounds without hearing aids) was also associated with decreased hearing aid wear time (negative association). Conclusions There are many complex audiologic and medical concerns that may affect hearing aid wear time in U.S. Military Veterans. Therefore, the information from this study should be expanded on prospectively by further exploring these associations, and their severity, on hearing aid wear time. The information from this and future studies may lead to clinical recommendations with the goal of increasing daily hearing aid use in this and other populations.

2020 ◽  
Vol 31 (05) ◽  
pp. 354-362
Author(s):  
Paula Folkeard ◽  
Marlene Bagatto ◽  
Susan Scollie

Abstract Background Hearing aid prescriptive methods are a commonly recommended component of evidence-based preferred practice guidelines and are often implemented in the hearing aid programming software. Previous studies evaluating hearing aid manufacturers' software-derived fittings to prescriptions have shown significant deviations from targets. However, few such studies examined the accuracy of software-derived fittings for the Desired Sensation Level (DSL) v5.0 prescription. Purpose The purpose of this study was to evaluate the accuracy of software-derived fittings to the DSL v5.0 prescription, across a range of hearing aid brands, audiograms, and test levels. Research Design This study is a prospective chart review with simulated cases. Data Collection and Analysis A set of software-derived fittings were created for a six-month-old test case, across audiograms ranging from mild to profound. The aided output from each fitting was verified in the test box at 55-, 65-, 75-, and 90-dB SPL, and compared with DSL v5.0 child targets. The deviations from target across frequencies 250-6000 Hz were calculated, together with the root-mean-square error (RMSE) from target. The aided Speech Intelligibility Index (SII) values generated for the speech passages at 55- and 65-dB SPL were compared with published norms. Study Sample Thirteen behind-the-ear style hearing aids from eight manufacturers were tested. Results The amount of deviation per frequency was dependent on the test level and degree of hearing loss. Most software-derived fittings for mild-to-moderately severe hearing losses fell within ± 5 dB of the target for most frequencies. RMSE results revealed more than 84% of those hearing aid fittings for the mild-to-moderate hearing losses were within 5 dB at all test levels. Fittings for severe to profound hearing losses had the greatest deviation from target and RMSE. Aided SII values for the mild-to-moderate audiograms fell within the normative range for DSL pediatric fittings, although they fell within the lower portion of the distribution. For more severe losses, SII values for some hearing aids fell below the normative range. Conclusions In this study, use of the software-derived manufacturers' fittings based on the DSL v5.0 pediatric targets set most hearing aids within a clinically acceptable range around the prescribed target, particularly for mild-to-moderate hearing losses. However, it is likely that clinician adjustment based on verification of hearing aid output would be required to optimize the fit to target, maximize aided SII, and ensure appropriate audibility across all degrees of hearing loss.


2018 ◽  
Vol 27 (4) ◽  
pp. 581-593 ◽  
Author(s):  
Lisa Brody ◽  
Yu-Hsiang Wu ◽  
Elizabeth Stangl

Purpose The aim of this study was to compare the benefit of self-adjusted personal sound amplification products (PSAPs) to audiologist-fitted hearing aids based on speech recognition, listening effort, and sound quality in ecologically relevant test conditions to estimate real-world effectiveness. Method Twenty-five older adults with bilateral mild-to-moderate hearing loss completed the single-blinded, crossover study. Participants underwent aided testing using 3 PSAPs and a traditional hearing aid, as well as unaided testing. PSAPs were adjusted based on participant preference, whereas the hearing aid was configured using best-practice verification protocols. Audibility provided by the devices was quantified using the Speech Intelligibility Index (American National Standards Institute, 2012). Outcome measures assessing speech recognition, listening effort, and sound quality were administered in ecologically relevant laboratory conditions designed to represent real-world speech listening situations. Results All devices significantly improved Speech Intelligibility Index compared to unaided listening, with the hearing aid providing more audibility than all PSAPs. Results further revealed that, in general, the hearing aid improved speech recognition performance and reduced listening effort significantly more than all PSAPs. Few differences in sound quality were observed between devices. All PSAPs improved speech recognition and listening effort compared to unaided testing. Conclusions Hearing aids fitted using best-practice verification protocols were capable of providing more aided audibility, better speech recognition performance, and lower listening effort compared to the PSAPs tested in the current study. Differences in sound quality between the devices were minimal. However, because all PSAPs tested in the study significantly improved participants' speech recognition performance and reduced listening effort compared to unaided listening, PSAPs could serve as a budget-friendly option for those who cannot afford traditional amplification.


Author(s):  
Andre Dao ◽  
Paula Folkeard ◽  
Sandra Baker ◽  
John Pumford ◽  
Susan Scollie

Abstract Background Matching hearing aid output levels to prescribed targets is a component of preferred practice, yet recent normative data on appropriateness of fittings are lacking. Verification measures that assess closeness of fit-to-target include raw deviations from target, root-mean-squared-error (RMSE) deviations from target, and aided Speech Intelligibility Index (SII) values. Establishing normative ranges for these measures may help hearing professionals determine whether a patient's fit-to-targets and/or aided speech audibility is typical for his or her degree of hearing loss. Purpose This article aims to characterize the range of fit-to-target and the range of aided SII associated with hearing aid fittings using the Desired Sensation Level version 5.0 (DSL v5-adult) prescription with adults, considering also hearing aid style, venting, and audiometric characteristics. Research design A descriptive and correlational study of data collected from a retrospective chart review. Results Hearing aid fittings to 281 ears were compiled. The four-frequency average deviation from target (RMSE) was within ± 5 dB of target in 77% of fittings for mid-level speech. Deviation from targets increased with hearing loss, particularly when the loss is greater than 85 dB hearing level or if the loss was steeply sloping. Venting increased the deviation from targets in the low frequencies. Aided SII values strongly correlated with the participants' hearing thresholds. Clinical ranges for RMSE and aided SII were developed for characterization of fitting outcomes. Conclusion Fitting to DSL v5-adult targets was observed within ± 5 dB absolute deviation, or within 5 dB RMSE, on average for typical adult hearing aid fittings. Confidence intervals for deviation from target and aided SII are proposed.


2020 ◽  
Vol 51 (1) ◽  
pp. 55-67 ◽  
Author(s):  
Ryan W. McCreery ◽  
Elizabeth A. Walker ◽  
Derek J. Stiles ◽  
Meredith Spratford ◽  
Jacob J. Oleson ◽  
...  

Purpose Because of uncertainty about the level of hearing where hearing aids should be provided to children, the goal of the current study was to develop audibility-based hearing aid candidacy criteria based on the relationship between unaided hearing and language outcomes in a group of children with hearing loss who did not wear hearing aids. Method Unaided hearing and language outcomes were examined for 52 children with mild-to-severe hearing losses. A group of 52 children with typical hearing matched for age, nonverbal intelligence, and socioeconomic status was included as a comparison group representing the range of optimal language outcomes. Two audibility-based criteria were considered: (a) the level of unaided hearing where unaided children with hearing loss fell below the median for children with typical hearing and (b) the level of unaided hearing where the slope of language outcomes changed significantly based on an iterative, piecewise regression modeling approach. Results The level of unaided audibility for children with hearing loss that was associated with differences in language development from children with typical hearing or based on the modeling approach varied across outcomes and criteria but converged at an unaided speech intelligibility index of 80. Conclusions Children with hearing loss who have unaided speech intelligibility index values less than 80 may be at risk for delays in language development without hearing aids. The unaided speech intelligibility index potentially could be used as a clinical criterion for hearing aid fitting candidacy for children with hearing loss.


Author(s):  
Paula Folkeard ◽  
Marlene Bagatto ◽  
Susan Scollie

Background: Hearing aid prescriptive methods are a commonly recommended component of evidencebasedpreferred practice guidelines and are often implemented in the hearing aid programming software.Previous studies evaluating hearing aid manufacturers’ software-derived fittings to prescriptionshave shown significant deviations from targets. However, few such studies examined the accuracy ofsoftware-derived fittings for the Desired Sensation Level (DSL) v5.0 prescription.<br />Purpose: The purpose of this study was to evaluate the accuracy of software-derived fittings to the DSLv5.0 prescription, across a range of hearing aid brands, audiograms, and test levels.<br />Research Design: This study is a prospective chart review with simulated cases.<br />Data Collection and Analysis: A set of software-derived fittings were created for a six-month-old testcase, across audiograms ranging from mild to profound. The aided output from each fitting was verified inthe test box at 55-, 65-, 75-, and 90-dB SPL, and compared with DSL v5.0 child targets. The deviationsfrom target across frequencies 250–6000 Hz were calculated, together with the root-mean-square error(RMSE) from target. The aided Speech Intelligibility Index (SII) values generated for the speech passagesat 55- and 65-dB SPL were compared with published norms.<br />Study Sample: Thirteen behind-the-ear style hearing aids from eight manufacturers were tested.<br />Results: The amount of deviation per frequency was dependent on the test level and degree of hearingloss. Most software-derived fittings for mild-to-moderately severe hearing losses fell within ±5 dB of thetarget for most frequencies. RMSE results revealed more than 84 percent of those hearing aid fittings for themild-to-moderate hearing losses were within 5 dB at all test levels. Fittings for severe to profound hearinglosses had the greatest deviation from target and RMSE. Aided SII values for the mild-to-moderate audiogramsfell within the normative range for DSL pediatric fittings, although they fell within the lower portionof the distribution. For more severe losses, SII values for some hearing aids fell below the normative range.<br />Conclusions: In this study, use of the software-derived manufacturers’ fittings based on the DSL v5.0pediatric targets set most hearing aids within a clinically acceptable range around the prescribed target,particularly for mild-to-moderate hearing losses. However, it is likely that clinician adjustment based onverification of hearing aid output would be required to optimize the fit to target, maximize aided SII, andensure appropriate audibility across all degrees of hearing loss.<br />


1986 ◽  
Vol 51 (4) ◽  
pp. 362-369 ◽  
Author(s):  
Donna M. Risberg ◽  
Robyn M. Cox

A custom in-the-ear (ITE) hearing aid fitting was compared to two over-the-ear (OTE) hearing aid fittings for each of 9 subjects with mild to moderately severe hearing losses. Speech intelligibility via the three instruments was compared using the Speech Intelligibility Rating (SIR) test. The relationship between functional gain and coupler gain was compared for the ITE and the higher rated OTE instruments. The difference in input received at the microphone locations of the two types of hearing aids was measured for 10 different subjects and compared to the functional gain data. It was concluded that (a) for persons with mild to moderately severe hearing losses, appropriately adjusted custom ITE fittings typically yield speech intelligibility that is equal to the better OTE fitting identified in a comparative evaluation; and (b) gain prescriptions for ITE hearing aids should be adjusted to account for the high-frequency emphasis associated with in-the-concha microphone placement.


Author(s):  
Isiaka Ajewale Alimi

Digital hearing aids addresses the issues of noise and speech intelligibility that is associated with the analogue types. One of the main functions of the digital signal processor (DSP) of digital hearing aid systems is noise reduction which can be achieved by speech enhancement algorithms which in turn improve system performance and flexibility. However, studies have shown that the quality of experience (QoE) with some of the current hearing aids is not up to expectation in a noisy environment due to interfering sound, background noise and reverberation. It is also suggested that noise reduction features of the DSP can be further improved accordingly. Recently, we proposed an adaptive spectral subtraction algorithm to enhance the performance of communication systems and address the issue of associated musical noise generated by the conventional spectral subtraction algorithm. The effectiveness of the algorithm has been confirmed by different objective and subjective evaluations. In this study, an adaptive spectral subtraction algorithm is implemented using the noise-estimation algorithm for highly non-stationary noisy environments instead of the voice activity detection (VAD) employed in our previous work due to its effectiveness. Also, signal to residual spectrum ratio (SR) is implemented in order to control the amplification distortion for speech intelligibility improvement. The results show that the proposed scheme gives comparatively better performance and can be easily employed in digital hearing aid system for improving speech quality and intelligibility.


2021 ◽  
Vol 11 (2) ◽  
pp. 200-206
Author(s):  
Gennaro Auletta ◽  
Annamaria Franzè ◽  
Carla Laria ◽  
Carmine Piccolo ◽  
Carmine Papa ◽  
...  

Background: The aim of this study was to compare, in users of bimodal cochlear implants, the performance obtained using their own hearing aids (adjusted with the standard NAL-NL1 fitting formula) with the performance using the Phonak Naìda Link Ultra Power hearing aid adjusted with both NAL-NL1 and a new bimodal system (Adaptive Phonak Digital Bimodal (APDB)) developed by Advanced Bionics and Phonak Corporations. Methods: Eleven bimodal users (Naìda CI Q70 + contralateral hearing aid) were enrolled in our study. The users’ own hearing aids were replaced with the Phonak Naìda Link Ultra Power and fitted following the new formula. Speech intelligibility was assessed in quiet and noisy conditions, and comparisons were made with the results obtained with the users’ previous hearing aids and with the Naída Link hearing aids fitted with the NAL-NL1 generic prescription formula. Results: Using Phonak Naìda Link Ultra Power hearing aids with the Adaptive Phonak Digital Bimodal fitting formula, performance was significantly better than that with the users’ own rehabilitation systems, especially in challenging hearing situations for all analyzed subjects. Conclusions: Speech intelligibility tests in quiet settings did not reveal a significant difference in performance between the new fitting formula and NAL-NL1 fittings (using the Naída Link hearing aids), whereas the performance difference between the two fittings was very significant in noisy test conditions.


1972 ◽  
Vol 37 (1) ◽  
pp. 113-117 ◽  
Author(s):  
Hedda Aufricht

A recent development in hearing aids, the contralateral routing of signals (CROS), makes it possible to provide amplification for persons with unilateral hearing loss. In 1967, a CROS eyeglass hearing aid was placed on government contract and made available to veterans. To study the efficiency of the CROS, a follow-up questionnaire was sent to 60 male veterans who had been fitted with this aid. All had demonstrated unilateral hearing losses, and the mean threshold for the speech frequencies (500–2000 Hz) in the good ear was 24 dB. The 54 replies (90%) indicated that 85% wore the aid, liked it, and derived benefit from it; 15% neither liked nor wore the aid. The CROS appeared to be most helpful in listening to conversational speech and at work, and most disturbing in a noisy environment. The complaints about the aid fell into major categories: 33% objected to its poor fit and construction and 11% were disturbed by speech distortion. The CROS aid has been a useful addition to the hearing-aid stock at the clinic reported here. It has expanded the program by providing amplification to veterans who could not be fitted with the conventional stock of aids.


2020 ◽  
Vol 5 (1) ◽  
pp. 36-39
Author(s):  
Mariya Yu. Boboshko ◽  
Irina P. Berdnikova ◽  
Natalya V. Maltzeva

Objectives -to determine the normative data of sentence speech intelligibility in a free sound field and to estimate the applicability of the Russian Matrix Sentence test (RuMatrix) for assessment of the hearing aid fitting benefit. Material and methods. 10 people with normal hearing and 28 users of hearing aids with moderate to severe sensorineural hearing loss were involved in the study. RuMatrix test both in quiet and in noise was performed in a free sound field. All patients filled in the COSI questionnaire. Results. The hearing impaired patients were divided into two subgroups: the 1st with high and the 2nd with low hearing aid benefit, according to the COSI questionnaire. In the 1st subgroup, the threshold for the sentence intelligibility in quiet was 34.9 ± 6.4 dB SPL, and in noise -3.3 ± 1.4 dB SNR, in the 2nd subgroup 41.7 ± 11.5 dB SPL and 0.15 ± 3.45 dB SNR, respectively. The significant difference between the data of both subgroups and the norm was registered (p