Long-Term Average Speech Spectra and Dynamic Ranges of 17 Indian Languages

2021 ◽  
pp. 1-12
Author(s):  
Vijaya Kumar Narne ◽  
Sreejith V. S. ◽  
Nachiketa Tiwari

Purpose: In this work, we have determined the long-term average speech spectra (LTASS) and dynamic ranges (DR) of 17 Indian languages. This work is important because LTASS and DR are language-dependent functions used to fit hearing aids, calculate the Speech Intelligibility Index, and recognize speech automatically. Currently, LTASS and DR functions for English are used to fit hearing aids in India. Our work may help improve the performance of hearing aids in the Indian context. Method: Speech samples from native talkers were used as stimuli in this study. Each speech sample was initially cleaned for extraneous sounds and excessively long pauses. Next, LTASS and DR functions for each language were calculated for different frequency bands. Similar analysis was also performed for English for reference purposes. Two-way analysis of variance was also conducted to understand the effects of important parameters on LTASS and DR. Finally, a one-sample t test was conducted to assess the significance of important statistical attributes of our data. Results: We showed that LTASS and DR for Indian languages are 5–10 dB and 11 dB less than those for English. These differences may be due to lesser use rate of high-frequency dominant phonemes and preponderance of vowel-ending words in Indian languages. We also showed that LTASS and DR do not differ significantly across Indian languages. Hence, we propose a common LTASS and DR for Indian languages. Conclusions: We showed that differences in LTASS and DR for Indian languages vis-à-vis English are large and significant. Such differences may be attributed to phonetic and linguistic characteristics of Indian languages.

2021 ◽  
Vol 6 (2) ◽  
pp. 127-134
Author(s):  
Vijaya Kumar Narne ◽  
Nachiketa Tiwari

Purpose: The Long-Term Average Speech Spectrum (LTASS) and Dynamic Range (DR) of speech strongly influence estimates of Speech Intelligibility Index (SII), gain and compression required for hearing aid fitting. It is also known that acoustic and linguistic characteristics of a language have a bearing on its LTASS and DR. Thus, there is a need to estimate LTASS and DR for Indian languages. The present work on three Indian languages fills this gap and contrasts LTASS and DR attributes of these languages against British English.Methods: For this purpose, LTASS and DR were measured for 21 one-third octave bands in the frequency range of 0.1 to 10 kHz for Hindi, Kannada, Indian English and British English.Results: Our work shows that the DR of Indian languages studied is 7-10 dB less relative to that of British English. We also report that LTASS levels for Indian languages are 7 dB lower relative to British English for frequencies above 1 kHz. Finally, we observed that LTASS and DR attributes across genders were more or less the same.Conclusions: Given the evidence presented in this work that LTASS and DR characteristics for Indian languages analyzed are markedly different than those for BE, there is a need to determine Indian language specific SII, as well as gain and compression parameters used in hearing aids.


2021 ◽  
Vol 25 ◽  
pp. 233121652198990 ◽  
Author(s):  
Jonathan M. Vaisberg ◽  
Steve Beaulac ◽  
Danielle Glista ◽  
Ewan A. Macpherson ◽  
Susan D. Scollie

Hearing aids are typically fitted using speech-based prescriptive formulae to make speech more intelligible. Individual preferences may vary from these prescriptions and may also vary with signal type. It is important to consider what motivates listener preferences and how those preferences can inform hearing aid processing so that assistive listening devices can best be tailored for hearing aid users. Therefore, this study explored preferred frequency-gain shaping relative to prescribed gain for speech and music samples. Preferred gain was determined for 22 listeners with mild sloping to moderately severe hearing loss relative to individually prescribed amplification while listening to samples of male speech, female speech, pop music, and classical music across low-, mid-, and high-frequency bands. Samples were amplified using a fast-acting compression hearing aid simulator. Preferences were determined using an adaptive paired comparison procedure. Listeners then rated speech and music samples processed using prescribed and preferred shaping across different sound quality descriptors. On average, low-frequency gain was significantly increased relative to the prescription for all stimuli and most substantially for pop and classical music. High-frequency gain was decreased significantly for pop music and male speech. Gain adjustments, particularly in the mid- and high-frequency bands, varied considerably between listeners. Music preferences were driven by changes in perceived fullness and sharpness, whereas speech preferences were driven by changes in perceived intelligibility and loudness. The results generally support the use of prescribed amplification to optimize speech intelligibility and alternative amplification for music listening for most listeners.


1986 ◽  
Vol 51 (4) ◽  
pp. 362-369 ◽  
Author(s):  
Donna M. Risberg ◽  
Robyn M. Cox

A custom in-the-ear (ITE) hearing aid fitting was compared to two over-the-ear (OTE) hearing aid fittings for each of 9 subjects with mild to moderately severe hearing losses. Speech intelligibility via the three instruments was compared using the Speech Intelligibility Rating (SIR) test. The relationship between functional gain and coupler gain was compared for the ITE and the higher rated OTE instruments. The difference in input received at the microphone locations of the two types of hearing aids was measured for 10 different subjects and compared to the functional gain data. It was concluded that (a) for persons with mild to moderately severe hearing losses, appropriately adjusted custom ITE fittings typically yield speech intelligibility that is equal to the better OTE fitting identified in a comparative evaluation; and (b) gain prescriptions for ITE hearing aids should be adjusted to account for the high-frequency emphasis associated with in-the-concha microphone placement.


2020 ◽  
Vol 31 (05) ◽  
pp. 354-362
Author(s):  
Paula Folkeard ◽  
Marlene Bagatto ◽  
Susan Scollie

Abstract Background Hearing aid prescriptive methods are a commonly recommended component of evidence-based preferred practice guidelines and are often implemented in the hearing aid programming software. Previous studies evaluating hearing aid manufacturers' software-derived fittings to prescriptions have shown significant deviations from targets. However, few such studies examined the accuracy of software-derived fittings for the Desired Sensation Level (DSL) v5.0 prescription. Purpose The purpose of this study was to evaluate the accuracy of software-derived fittings to the DSL v5.0 prescription, across a range of hearing aid brands, audiograms, and test levels. Research Design This study is a prospective chart review with simulated cases. Data Collection and Analysis A set of software-derived fittings were created for a six-month-old test case, across audiograms ranging from mild to profound. The aided output from each fitting was verified in the test box at 55-, 65-, 75-, and 90-dB SPL, and compared with DSL v5.0 child targets. The deviations from target across frequencies 250-6000 Hz were calculated, together with the root-mean-square error (RMSE) from target. The aided Speech Intelligibility Index (SII) values generated for the speech passages at 55- and 65-dB SPL were compared with published norms. Study Sample Thirteen behind-the-ear style hearing aids from eight manufacturers were tested. Results The amount of deviation per frequency was dependent on the test level and degree of hearing loss. Most software-derived fittings for mild-to-moderately severe hearing losses fell within ± 5 dB of the target for most frequencies. RMSE results revealed more than 84% of those hearing aid fittings for the mild-to-moderate hearing losses were within 5 dB at all test levels. Fittings for severe to profound hearing losses had the greatest deviation from target and RMSE. Aided SII values for the mild-to-moderate audiograms fell within the normative range for DSL pediatric fittings, although they fell within the lower portion of the distribution. For more severe losses, SII values for some hearing aids fell below the normative range. Conclusions In this study, use of the software-derived manufacturers' fittings based on the DSL v5.0 pediatric targets set most hearing aids within a clinically acceptable range around the prescribed target, particularly for mild-to-moderate hearing losses. However, it is likely that clinician adjustment based on verification of hearing aid output would be required to optimize the fit to target, maximize aided SII, and ensure appropriate audibility across all degrees of hearing loss.


2021 ◽  
pp. 1-6
Author(s):  
Nicholas P. Giuliani

Purpose A retrospective analysis was conducted to explore how tinnitus, one or more neurologic conditions, unaided speech intelligibility index, and other comorbidities impact the average number of hours hearing aids are worn each day by U.S. Military Veterans. Method Medical records and a hearing aid database were queried to obtain information regarding active medical problems and average daily hearing aid wear time. Multiple linear regression was used to explore these relationships for 215 male Veterans whose records were available from 2009 to 2020. To be analyzed, Veterans must have possessed their hearing aid(s) for at least 3 consecutive months. Results An active problem of subjective tinnitus was associated with increased hearing aid wear time (positive association) and one or more active neurologic conditions were associated with decreased hearing aid wear time (negative association). A high unaided speech intelligibility index (greater access to speech sounds without hearing aids) was also associated with decreased hearing aid wear time (negative association). Conclusions There are many complex audiologic and medical concerns that may affect hearing aid wear time in U.S. Military Veterans. Therefore, the information from this study should be expanded on prospectively by further exploring these associations, and their severity, on hearing aid wear time. The information from this and future studies may lead to clinical recommendations with the goal of increasing daily hearing aid use in this and other populations.


2018 ◽  
Vol 27 (4) ◽  
pp. 581-593 ◽  
Author(s):  
Lisa Brody ◽  
Yu-Hsiang Wu ◽  
Elizabeth Stangl

Purpose The aim of this study was to compare the benefit of self-adjusted personal sound amplification products (PSAPs) to audiologist-fitted hearing aids based on speech recognition, listening effort, and sound quality in ecologically relevant test conditions to estimate real-world effectiveness. Method Twenty-five older adults with bilateral mild-to-moderate hearing loss completed the single-blinded, crossover study. Participants underwent aided testing using 3 PSAPs and a traditional hearing aid, as well as unaided testing. PSAPs were adjusted based on participant preference, whereas the hearing aid was configured using best-practice verification protocols. Audibility provided by the devices was quantified using the Speech Intelligibility Index (American National Standards Institute, 2012). Outcome measures assessing speech recognition, listening effort, and sound quality were administered in ecologically relevant laboratory conditions designed to represent real-world speech listening situations. Results All devices significantly improved Speech Intelligibility Index compared to unaided listening, with the hearing aid providing more audibility than all PSAPs. Results further revealed that, in general, the hearing aid improved speech recognition performance and reduced listening effort significantly more than all PSAPs. Few differences in sound quality were observed between devices. All PSAPs improved speech recognition and listening effort compared to unaided testing. Conclusions Hearing aids fitted using best-practice verification protocols were capable of providing more aided audibility, better speech recognition performance, and lower listening effort compared to the PSAPs tested in the current study. Differences in sound quality between the devices were minimal. However, because all PSAPs tested in the study significantly improved participants' speech recognition performance and reduced listening effort compared to unaided listening, PSAPs could serve as a budget-friendly option for those who cannot afford traditional amplification.


2007 ◽  
Vol 18 (04) ◽  
pp. 274-281 ◽  
Author(s):  
Gene W. Bratt ◽  
Mia A.L. Rosenfeld ◽  
David W. Williams

This report provides background regarding the Long Term Follow-Up of Patients in the NIDCD/VA Hearing Aid Clinical Trial study and serves as an introduction to the detailed reports that follow in this issue of Journal of the American Academy of Audiology. The authors investigated five- to seven-year benefit/satisfaction in participants from the original NIDCD/VA Hearing Aid Clinical Trial. The new study was designed to investigate current use of the original study hearing aids, to compare changes in selected audiological measures, and to assess possible predictors of long-term hearing aid use. The outcome measures included estimates of speech intelligibility in quiet and noise, self-reported patterns of hearing aid usage, self-reported estimates of activity limitations and quality-of-life issues, estimates of hearing aid satisfaction, and self-reported hearing aid benefit. Overall, the short-term benefits of hearing aid use observed during the original trial were noted to persist in the long term. Este reporte suministra información relacionada con el Seguimiento a Largo Plazo de los Pacientes del Estudio Clínico de Auxiliares Auditivos del NIDCD/VA, y sirve como una introducción de los reportes detallados que siguen a continuación en esta edición del Journal de la Academia Americana de Audiología. Los autores investigaron por cinco a siete años la satisfacción/beneficio en los participantes del Estudio Clínico de Auxiliares Auditivos del NIDCD/VA original. El nuevo estudio fue designado para investigar el uso actual de los auxiliares auditivos (AA) originales del estudio, para comparar cambios en las medidas audiológicas seleccionadas, y evaluar posibles elementos de predicción a largo plazo en el uso de AA. Las medidas de resultado incluyeron estimados de la inteligibilidad del lenguaje en silencio y en ruido, patrones auto-reportados de uso del AA, estimaciones auto-reportadas de limitación en la actividad y en asuntos de calidad de vida, estimaciones de satisfacción en el uso del AA y auto-reportes de beneficios con el AA. Globalmente, los beneficios a corto plazo del uso de auxiliares auditivos durante el estudio original persistieron en el largo plazo.


CoDAS ◽  
2015 ◽  
Vol 27 (1) ◽  
pp. 37-43 ◽  
Author(s):  
Vanessa Clarizia Marchesin ◽  
Maria Cecília Martinelli Iório

PURPOSE: To verify the effect of long-term use of hearing aids with frequency compression for verbal behavior tests and daily activities. METHODS: Thirty-two adults, aged between 30 and 60 years old, with moderate to severe sensorineural hearing loss at high frequencies with steeply sloping configuration were divided into two groups: 16 with hearing aids with frequency compression algorithm enabled and 16 not enabled. All participants underwent the detection tests of consonant sounds, monosyllable recognition in quiet environments, identification of fricative monosyllables, and Abbreviated Profile of Hearing Aid Benefit (APHAB) questionnaire in five times throughout a 12-month trial. RESULTS: Detection of consonant sounds, recognition of monosyllables in quiet environments and identification of fricative monosyllables improved significantly with frequency compression enabled. Participants had their APHAB scores improved whether they were adapted to the frequency compression or not. CONCLUSION: Frequency compression provides the anticipated improvement in audibility, detection of high-frequency consonant sounds, and recognition of monosyllables.


2012 ◽  
Vol 55 (3) ◽  
pp. 764-778 ◽  
Author(s):  
Derek J. Stiles ◽  
Ruth A. Bentler ◽  
Karla K. McGregor

Purpose To determine whether a clinically obtainable measure of audibility, the aided Speech Intelligibility Index (SII; American National Standards Institute, 2007), is more sensitive than the pure-tone average (PTA) at predicting the lexical abilities of children who wear hearing aids (CHA). Method School-age CHA and age-matched children with normal hearing (CNH) repeated words and nonwords, learned novel words, and completed a standardized receptive vocabulary test. Analyses of covariance allowed comparison of the 2 groups. For CHA, regression analyses determined whether SII held predictive value over and beyond PTA. Results CHA demonstrated poorer performance than CNH on tests of word and nonword repetition and receptive vocabulary. Groups did not differ on word learning. Aided SII was a stronger predictor of word and nonword repetition and receptive vocabulary than PTA. After accounting for PTA, aided SII remained a significant predictor of nonword repetition and receptive vocabulary. Conclusions Despite wearing hearing aids, CHA performed more poorly on 3 of 4 lexical measures. Individual differences among CHA were predicted by aided SII. Unlike PTA, aided SII incorporates hearing aid amplification characteristics and speech-frequency weightings and may provide a more valid estimate of the child's access to and ability to learn from auditory input in real-world environments.