New high-voltage directional and phase selection protection technique based on real power system data

2012 ◽  
Vol 6 (11) ◽  
pp. 1075-1085 ◽  
Author(s):  
M.M. Eissa ◽  
M.M.A. Mahfouz
2016 ◽  
Vol 31 (3) ◽  
pp. 2501-2502 ◽  
Author(s):  
M. Sahraei-Ardakani ◽  
X. Li ◽  
P. Balasubramanian ◽  
K. W. Hedman ◽  
M. Abdi-Khorsand

2013 ◽  
Vol 14 (2) ◽  
Author(s):  
Surajit Chattopadhyay ◽  
Samarjit Sengupta

ABSTRACT: This paper presents harmonic distortion assessment by area based approach at single phasing of an induction motor. This has been achieved by assessing voltage and current signals using area based approach. Some specific reference signals have been defined, after which, real power system data are plotted with this reference signal and areas thus formed by the real power system data with the reference signal have been calculated wherefrom contributions of fundamental waveform and harmonic components in real and reactive powers have been assessed separately. Single phasing is done on induction machine and total harmonic distortion factors have then been calculated. Significant change is observed in harmonic distortion due to single phasing. ABSTRAK: Kertas kerja ini membentangkan penilaian herotan harmonik menggunakan kaedah keluasan kawasan pada pemfasaan tunggal motor aruhan. Menggunakan kaedah keluasan kawasan, penilaian terhasil dengan memantau isyarat arus dan voltan. Sesetengah isyarat rujukan tertentu dikenal pasti, di mana, data sistem kuasa sebenar diplotkan berdasarkan isyarat rujukan ini. Kawasan kemudiannya dibentuk dengan adanya data sistem kuasa sebenar dengan menggunakan pengiraan isyarat rujukan. Pengiraan ini memberikan bentuk gelombang asas dan komponen harmonik sebenar di mana kuasa reaktif ditentukan secara berasingan. Pemfasaan tunggal ditentukan menggunakan mesin aruhan dan faktor jumlah herotan harmonik diambil kira .Perubahan yang ketara dikenal pasti dalam herotan harmonik yang disebabkan oleh pemfasaan tunggal.


SoftwareX ◽  
2021 ◽  
Vol 15 ◽  
pp. 100747
Author(s):  
José Daniel Lara ◽  
Clayton Barrows ◽  
Daniel Thom ◽  
Dheepak Krishnamurthy ◽  
Duncan Callaway

2018 ◽  
Vol 7 (3.36) ◽  
pp. 127 ◽  
Author(s):  
Nishanthi Sunthrasakaran ◽  
Nor Akmal Mohd Jamail ◽  
Qamarul Ezani Kamarudin ◽  
Sujeetha Gunabalan

The most important aspect influencing the circumstance and characteristics of electrical discharges is the distribution of electric field in the gap of electrodes. The study of discharge performance requires details on the variation of maximum electric field around the electrode. In electrical power system, the insulation of high voltage power system usually subjected with high electric field. The high electric field causes the degradation performance of insulation and electrical breakdown start to occur. Generally, the standard sphere gaps widely used for protective device in electrical power equipment. This project is study about the electric field distribution and current density for different electrode configuration with XLPE barrier. Hence, the different electrode configuration influences the electric field distribution. This project mainly involves the simulation in order to evaluate the maximum electric field for different electrode configuration. Finite Element Method (FEM) software has been used in this project to perform the simulation. This project also discusses the breakdown characteristics of the XLPE. The accurate evaluation of electric field distribution and maximum electric field is an essential for the determination of discharge behavior of high voltage apparatus and components. The degree of uniformity is very low for pointed rod-plane when compared to other two electrode configurations. The non- uniform electric distribution creates electrical stress within the surface of dielectric barrier. As a conclusion, when the gap distance between the electrodes increase the electric field decrease.  


2013 ◽  
Vol 380-384 ◽  
pp. 3213-3216
Author(s):  
Hai Yan Wang ◽  
Duan Lei Yuan ◽  
Chen Xu Niu ◽  
Hua Jun Dong

In this paper, mainly for the problem that high voltage circuit breaker closing at the random phase can bring hard harmfulness to the power system. We design the 35kV SF6-Phase Control circuit breaker can control speed smartly, and opens or closes with phase selection, which is equipped with the magnetic actuator. In the article, the static and transient simulation analysis which includes the load force, and carried out prototype trial and test validation. At last, the results of simulation and test is given.


Sign in / Sign up

Export Citation Format

Share Document