scholarly journals Seasonal coefficient of performance for ground source heat pump and groundwater one in Białystok

2017 ◽  
Vol 22 ◽  
pp. 00050 ◽  
Author(s):  
Andrzej Gajewski
2014 ◽  
Vol 1008-1009 ◽  
pp. 226-230 ◽  
Author(s):  
Bo Peng ◽  
Na Zhu ◽  
Ping Fang Hu ◽  
Li Peng ◽  
Fei Lei

This study analyze the actual operation performance and energy efficiency of thirty-nine ground source heat pump (GSHP) systems based on site tests in Wuhan, China. These systems include ground couple heat pump (GCHP) systems, ground water heat pump (GWHP) systems and hybrid ground source heat pump (HGSHP) systems. The results show that energy-saving rates reach 30% for most of the systems using method recommended by Assessment Guideline. The coefficient of performance (COP) of the systems varies as follow: 2.6-4.85 for GCHP systems; 2.58-3.74 for GWHP systems; 2.66-5.67 for combined heat pump systems. According to the test results and system design data, analyses the factors affecting the system performance of three types of ground source heat pump systems.


2014 ◽  
Vol 5 (2) ◽  
pp. 173-179
Author(s):  
T. Buday ◽  
Gy. Szabó ◽  
I. Fazekas ◽  
M. Paládi ◽  
Sz. Szabó ◽  
...  

Heating with the use of ambient energy by heat pumps is a very effective way to reduce CO2 emission. However, efficiency, economic and environmental advantages depend on the type of the heat pump and the temperature of the source, the latter usually changes during the heating season. The aim of the paper is to give the annual pattern of the COP and emission as a function of the typical source temperature pattern, moreover yearly summarized energetic and emission values are also added in the case of air source, water source and ground source heat pump systems, compared to some conventional heating mode.


Author(s):  
Birol I. Kilkis ◽  
Siir Kilkis

This study analyzes environmental, energy, and economical benefits of a ground source heat pump coupled poly-generation system by incorporating exergy into the energy efficiency analysis. Two additional terms, namely the rational exergy efficiency and the coefficient of performance were introduced to the primary energy savings equation in the European Union Directive 2004/8/EC. Based on the new equation, an optimization algorithm was developed, which can quantify the environmental, energy and economy benefits of any poly-generation system in a broader extent and scope. This algorithm was used to investigate the factors affecting the optimum split of the power generated by a poly-generation system between the heat pump and the customer. A base system was analyzed, which consists of a ground-source heat pump (GSHP) and a combined heat and power (CHP) system. Results show that any increase in the split in favor of the heat pump boosts the primary energy savings potential and thus CO2 emissions reducing potential while the pay-back period of the system is reduced. When all the constraints, including electricity and fuel costs in the energy market are taken into account, a one-to-three split seems to be optimal for many practical applications. It is concluded that benefits of CHP may be enhanced by GSHP coupling pending a careful exergy balance analysis between the resource supply and the application demand. This paper provides the fundamentals of the algorithm and discusses that a win-win-win situation among the environment, energy, and economy is feasible, most importantly, from the global warming perspective.


Author(s):  
X. Yu ◽  
X. Q. Zhai ◽  
R. Z. Wang

A constant temperature and humidity air-conditioning system driven by a ground source heat pump was designed and constructed in an archives building in Shanghai. The system consists of a water-to-water heat pump and 280 boreholes with 80 m in depth. During the operation in summer, the heat extraction from the condenser of the heat pump was divided: Part was rejected to the soil, while another was used to reheat the air in air handling units (AHUs). According to the experimental results under a typical summer weather condition of Shanghai, the average coefficient of performance of the heat pump was 5.4. The average indoor temperature and relative humidity of the archives house were 22.8°C and 46.6%, respectively. Since part of the heat extraction from the condenser was used to reheat the air in AHUs, the heat rejected to the soil was reduced by 23%, which was helpful for the earth energy conservation. According to the theoretical analysis, the distance between two boreholes is suggested to be 4–5 m. The deepness of the boreholes is suggested to be 80–100 m in Shanghai.


2018 ◽  
Vol 22 (Suppl. 2) ◽  
pp. 491-496
Author(s):  
Qianjun Mao ◽  
Yufeng Chen ◽  
Suisui Jin ◽  
Lei Shi ◽  
Liangli Xiao

Coefficient of performance of air conditioning system is the ratio of cooling capacity and power consumption, and also is an important parameter to characterize the performance of the system. Based on an actual ground source heat pump system in Wuhan, China, this paper calculated the coefficient of performance of the system under long-term continuous cooling operation and then evaluated the performance of the system through experiment. The continuous testing time ranged from June 1, 2017, to June 15, 2017, and the outside air temperature ranged from 21?C to 32?C during the testing progress. The experimental results show that the coefficient of performance of the system changes non-linearly with time, and varies greatly with the atmospheric temperature. The results also show that the coefficient of performances average value of the system is about 3.3, and the system has good performance under refrigeration conditions. This paper helps to understand the changes in the distribution characteristics of the coefficient of performance of the ground source heat pump system and promote the wide application of the ground source heat pump system.


2014 ◽  
Vol 1070-1072 ◽  
pp. 349-352
Author(s):  
Fei Lei ◽  
Ping Fang Hu

The energy efficiencies of two kinds of ground-source heat pump systems (GSHPs) are evaluated in this study based on field data. The two kinds of GSHPs are a ground-coupled heat pump system (GCHPs) and a groundwater heat pump system (GWHPs) which were installed in two apartment buildings of wuhan, respectively. We monitored various operating parameters, including the outdoor temperature, the flow rate, the electrical consumption and the water temperature. The values of coefficient of performance (COP) of system and chiller were evaluated based on a series of measurements. The seasonal COP of the chillers of the GCHPs and the GSHPs were 4.45 and 3.94 in the cooling season, 5.07 and 3.69 in the heating season. The comparison of COP implies that the GWHPs is more efficient than the GCHPs due to its steady water temperature of ground source heat exchanger.